首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   34篇
  免费   3篇
化学   29篇
数学   5篇
物理学   3篇
  2023年   1篇
  2021年   1篇
  2020年   1篇
  2019年   2篇
  2017年   1篇
  2016年   1篇
  2015年   1篇
  2014年   5篇
  2013年   4篇
  2012年   1篇
  2011年   6篇
  2010年   1篇
  2008年   1篇
  2006年   2篇
  2004年   1篇
  2003年   1篇
  2002年   2篇
  1980年   2篇
  1974年   1篇
  1971年   1篇
  1968年   1篇
排序方式: 共有37条查询结果,搜索用时 15 毫秒
1.
This paper focuses on the use of PQQ-dependent enzymes (PQQ enzymes) in amperometrical biosensors and gives emphasis on their innovative designs and applications. The study covers some aspects in the evolution of biosensors based on PQQ enzymes. Main attention is focused on the electrochemical properties of PQQ enzymes as very promising materials for the formation of electrochemical biosensors. Immobilization approaches and redox mediators recently used in PQQ enzymes based biosensors are reviewed. The acceptance of polypyrrole as a very promising immobilization matrix for some PQQ enzymes is discussed.  相似文献   
2.
In this study graphite electrodes modified by a thin DNA‐imprinted polypyrrole layer, which was able to bind specific target‐DNA, are reported. For this aim, electrochemical synthesis of polypyrrole was performed on a pencil graphite electrode by cyclic voltammetry (CV) or by potential pulse sequences (PPS). The modified electrode surface was used for electrochemical determination of target‐DNA by differential pulse voltammetry. According to our best knowledge this is a first report on the application of DNA‐imprinted polymer for the determination of target‐DNA. The results showed that the molecularly imprinted polypyrrole (MIPPy) layer that formed on the carbon electrode surface was sensitive for target‐DNA, while the nonimprinted polypyrrole layer was not sensitive to the same target‐DNA. Comparison of electrodes modified using PPS and CV techniques is presented.  相似文献   
3.
Glucose oxidase (GOx) from Penicillium funiculosum 46.1 was purified using step-by-step ultrafiltration and it was characterized by spectrophotometric and spectrofluorometric methods. It was shown that spectra of GOx produced by P. funiculosum are typical for flavoproteins. Absorption spectrum has distinct peaks at 380 and 457 nm, excitation spectrum at 373 and 447 nm, and emission spectrum at 530 and 562 nm. The pH correlation of enzyme activity and catalytic characteristics in various buffer systems (phosphate (pH 5.0–9.0), citrate (pH 3.0–5.0), citrate-phosphate (pH 3.0–9.0), and universal (pH 3.0–9.0)) were registered. It was determined that the GOx is the most efficiently interacting with substrate (glucose) in phosphate buffer at pH 7.0 with k cat/K m?=?21,825 M?1 s?1. Interaction of several different redox mediators (9,10-phenantroline-5,6-dione, 9,10-phenanthrenequinone, N-methylphenazonium methyl sulfate, ferrocene, ferrocenecarboxylic acid, α-methylferrocenemethanol, ferrocenecarboxaldehyde) with GOx from P. funiculosum was investigated by evaluation of the difference in fluorescence emission intensity of FAD(oxidized) and FADH2(reduced) forms. It was found that 9,10-phenantroline-5,6-dione and 9,10-phenanthrenequinone are the best redox mediators for this type of GOx.
Figure
?  相似文献   
4.
In this study the redox activity of human myocardium‐derived mesenchymal stem cells (hmMSC) were investigated by redox‐competition (RC‐SECM) and generation‐collection (GC‐SECM) modes of scanning electrochemical microscopy (SECM), using 2‐methylnaphthalene‐1,4‐dione (menadione, MD) as a redox mediator. The redox activity of human healthy and dilated hmMSCs was evaluated by measuring reduction of MD. Measurements were performed by approaching and retracting the UME from the surface of growing hmMSC cells. The current study shows that the RC‐SECM mode can be applied to investigate integrity of cell membranes, whereas the most promising results were observed by using the GC‐SECM mode and applying the Hill's equation for the calculation/fitting of dependencies of electrical current vs menadione concentration. The calculated apparent Michaelis constant (KM) for the production of menadiol (MDH2) in the pathological hmMSC cells was 14.4 folds higher compared to that of the healthy hmMSC revealing the lover redox activity of pathological cells. Moreover, the calculated Hill's coefficient n shows a negative cooperative binding between MD and healthy hmMSC and positive cooperative binding between MD and pathological hmMSC. It means that healthy hmMSC is of lower affinity to MD, which is also related to the better membrane integrity of healthy cells. Data of this study demonstrate that SECM can be applied to investigate intracellular redox and membrane changes ongoing in human dilated myocardium‐derived hmMSC in order to improve their functioning and further regenerative potential.  相似文献   
5.
In chi(2) three-wave mixing, the noise-seeded spatiotemporal modulational instability has a dramatic impact on the spatial soliton formation and on their stability, leading to the occurrence of a temporal breakup on the 20 fs scale and to the counterintuitive observation of spatial solitons with no apparent participation of the high-frequency field in the self-trapping.  相似文献   
6.
High-frequency (40 MHz) and low-frequency (7 MHz) capacitive micromachined ultrasound transducers (CMUT) were fabricated and tested for use in gravimetric detection of biomolecules. The low-frequency CMUT sensors have a gold-coated surface, while the high-frequency sensors have a silicon nitride surface. Both surfaces were functionalized with bovine leukemia virus antigen gp51 acting as the antigen. On addition of an a specific antibody labeled with horseradish peroxidase (HRP), the antigen/antibody complex is formed on the surface and quantified by HRP-catalyzed oxidation of tetramethylbenzidine. It has been found that a considerably smaller quantity of immuno complex is formed on the high frequency sensor surface. In parallel, the loading of the surface of the CMUT was determined via resonance frequency and electromechanical resistance readings. Following the formation of the immuno complexes, the resonance frequencies of the low-frequency and high-frequency sensors decrease by up to 420 and 440 kHz, respectively. Finite element analysis reveals that the loading of the (gold-coated) low frequency sensors is several times larger than that on high frequency sensors. The formation of the protein film with pronounced elasticity and stress on the gold surface case is discussed. We also discuss the adoption of this method for the detection of DNA using a hybridization assay following polymerase chain reaction. Figure
Resonant gravimetric immunosensing with six-channel, 7 MHz capacitive micromachined ultrasound transducer (CMUT). Initial modification by antigen gp51 builds the protein layer with 13.2 GPa elasticity modulus. This increases the resonance frequency of CMUT, which is decreasing after immune complex with antibody is established.  相似文献   
7.
Chemical pretreatment is widely used to facilitate transformation of living cells when foreign components are introduced into a cell through the cell wall. The influence of appropriate chemicals on the wall properties and mechanism of transformation is still a matter of intensive studies. Saccharomyces cerevisiae cells (also known as baker's yeast) were investigated by atomic force microscopy (AFM). The cell walls were modified by lithium acetate and dithiothreitol. The AFM imaging was performed in liquid water‐based environment. The living cells were fixed by trapping into the holes of a polycarbonate membrane. Mechanical and morphological properties of initial intact cells and treated cells were investigated. The increased stiffness of the chemically treated cells was observed. As deduced from the applied theoretical Hertz‐Sneddon model, the treated cells show completely different response mechanism to applied mechanical pressure in comparison with the intact cells. Also, the increased roughness of the cell wall of the treated yeasts was observed. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   
8.
9.
10.
In this work, three types of electrodes suitable for amperometric glucose biosensors were designed. One type of electrode was based on bio‐selective layer of polypyrrole/(glucose oxidase)/(Prussian Blue) (Ppy/GOx/PB) and it was used as a control electrode regarding to which electrochemical properties of two other types of electrodes were compared. During the formation of Prussian blue layers graphite electrodes were additionally modified by Ni‐hexacyanoferrate (NiHCF) and by Co‐hexacyanoferrate (CoHCF) in order to design Ppy/GOx/PB‐NiHCF and Ppy/GOx/PB‐CoHCF electrodes, respectively. Some physicochemical characteristics of all three types of electrodes were evaluated and compared. The Ppy/GOx/PB‐NiHCF electrode showed wider linear range of the calibration curve than Ppy/GOx/PB and Ppy/GOx/PB‐CoHCF electrodes. The effect of temperature on analytical performance of the Ppy/GOx/PB‐NiHCF based biosensor has been evaluated and activation energy of enzyme catalysed reaction has been calculated within the temperature range of 15 °C to 30 °C.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号