首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   54篇
  免费   0篇
化学   48篇
数学   2篇
物理学   4篇
  2021年   3篇
  2019年   1篇
  2013年   9篇
  2012年   3篇
  2011年   2篇
  2010年   3篇
  2009年   5篇
  2008年   3篇
  2007年   3篇
  2006年   4篇
  2005年   3篇
  2004年   5篇
  2003年   2篇
  2002年   4篇
  2001年   2篇
  2000年   1篇
  1996年   1篇
排序方式: 共有54条查询结果,搜索用时 31 毫秒
1.
Various digestion procedures were carefully investigated and accurately evaluated with respect to their effect on the analysis of cereals and cereal flours. Multielement methods were selected and well developed for the determination of essential (Cr, Cu, Fe, Mg, Mn, and Zn), nonessential (Ag, Al, Ba, Bi, In, and Ga), and toxic (Cd and Pb) minor and trace elements by inductively coupled plasma-atomic emission spectrometry. Only Ag could be determined, either with aqueous standard or standard addition calibration methods, while the standard addition methods were more accurate for the determination of other elements. The recoveries were mostly within the range of 84.1-113% for the expected values of all analytes with respect to certified reference material NIST SRM 1586a (rice flour). The results proved that, for cereals and cereal flours, the use of H2O2 for wet digestion and HNO3 for dry ashing were not necessary. Linear regression analysis and Student's paired t-test were applied to evaluate the significant differences between different procedures and type of samples.  相似文献   
2.
A robust flow injection (FI) on-line liquid-liquid extraction (LLE) preconcentration/separation system associated with a newly designed gravitational phase separator, coupled to flame atomic absorption spectrometry (FAAS) was developed. The performance of the system was illustrated for cadmium determination at the μg l−1 level. The non-charged cadmium complex with ammonium pyrrolidine dithiocarbamate (APDC) was extracted on-line into isobutyl methyl ketone (IBMK). The organic phase was effectively separated from a large volume of aqueous phase and is led into a 100 μl loop of an injection valve before its introduction into the nebulizer. The system was optimized and offered good performance characteristics with unlimited life time of phase separator, greater flow rate ratios and improved flexibility, as compared with other solvent extraction preconcentration systems. With a sampling frequency of 33 h−1, the enhancement factor was 155, the detection limit was 0.02 μg l−1, the relative standard deviation was 3.2% at 2.0 μg l−1 Cd concentration level and the calibration curve was linear over the concentration range 0.06-6.0 μg l−1. The accuracy of the proposed method was evaluated by analyzing a certified reference material of water and by recovery measurements on spiked samples. Finally, it was successfully applied to the analysis of tapwater, river and seawater samples.  相似文献   
3.
A simple and robust on-line sequential insertion system coupled with hydride generation atomic absorption spectrometry (HG-AAS) was developed, for selective As(III) and total inorganic arsenic determination without pre-reduction step. The proposed manifold, which is employing an integrated reaction chamber/gas-liquid separator (RC-GLS), is characterized by the ability of the successful managing of variable sample volumes (up to 25 ml), in order to achieve high sensitivity. Arsine is able to be selectively generated either from inorganic As(III) or from total arsenic, using different concentrations of HCl and NaBH4 solutions. For 8 ml sample volume consumption, the sampling frequency is 40 h−1. The detection limit is cL = 0.1 and 0.06 μg l−1 for As(III) and total arsenic, respectively. The precision (relative standard deviation) at 2.0 μg l−1 (n = 10) level is sr = 2.9 and 3.1% for As(III) and total arsenic, respectively. The performance of the proposed method was evaluated by analyzing the certified reference material NIST CRM 1643d and spiked water samples with various concentration ratios of As(III) to As(V). The method was applied for arsenic speciation in natural waters samples.  相似文献   
4.
Abstract

This review aims to provide a critical overview of automated flow injection and sequential injection liquid-liquid extraction for preconcentration and/or separation of ultra-trace metal and metalloid species hyphenated with atomic spectrometric detection systems, including some new trends and applications in the subbranches of cloud point extraction (CPE), wetting film extraction (WFE), supported liquid membrane extraction (SLME), extraction chromatography (EChr), and liquid-phase microextraction (LPME) techniques. The analytical performance of flow-injection/sequential injection liquid-liquid extraction methods is markedly affected by the components of the flow network such as segmentor, extraction coil, and phase separator. Thus, an overall presentation of system components along with some novel strategies for interface with atomic spectrometers is discussed and exemplified with selected applications.  相似文献   
5.
A novel automatic on-line liquid phase micro-extraction method based on drop-in-plug sequential injection lab-at-valve (LAV) platform was proposed for metal preconcentration and determination. A flow-through micro-extraction chamber mounted at the selection valve was adopted without the need of sophisticated lab-on-valve components. Coupled to flame atomic absorption spectrometry (FAAS), the potential of this lab-at-valve scheme is demonstrated for trace lead determination in environmental and biological water samples. A hydrophobic complex of lead with ammonium pyrrolidine dithiocarbamate (APDC) was formed on-line and subsequently extracted into an 80 μL plug of chloroform. The extraction procedure was performed by forming micro-droplets of aqueous phase into the plug of the extractant. All critical parameters that affect the efficiency of the system were studied and optimized. The proposed method offered good performance characteristics and high preconcentration ratios. For 10 mL sample consumption an enhancement factor of 125 was obtained. The detection limit was 1.8 μg L−1 and the precision expressed as relative standard deviation (RSD) at 50.0 μg L−1 of lead was 2.9%. The proposed method was evaluated by analyzing certified reference materials and applied for lead determination in natural waters and urine samples.  相似文献   
6.
Abstract

Total phenols were determined by molecular spectrophotometry, after distillation, complexation with 4-aminoantipyrine and extraction into chloroform. Cyanides were also determined spectrophotometrically after distillation from the acidified samples, and complexation in moderate acidic solution with barbituric acid. The dynamic ranges were 0 – 100 μg L?1 for total phenols and 0 – 30 μg L?1 for cyanides. The above methods were applied in the analysis of river, lake and stream waters collected from Northern Greece. The seasonal and spatial variation of concentrations was evaluated by two-way ANOVA. Background levels (4 – 12 μg L?1 for total phenols and 0.3 – 3 μg L?1 for cyanides), were found in almost all surface waters, with some exceptions.  相似文献   
7.
A flow injection system was developed for on-line sorbent extraction preconcentration and flame atomic absorption spectrometric determination of cadmium in natural water samples. The non-charged cadmium complex with diethyl-dithiophosphate (DDPA) was formed on-line in 0.1 mol L−1 HNO3 and retained on the hydrophobic poly-chlorotrifluoroethylene (PCTFE) sorbent material. The adsorbed complex was eluted with isobutyl methylketone (IBMK) and injected directly into the nebulizer via a flow compensation unit. All major chemical and flow parameters affecting the complex formation adsorption and elution as well as interference were studied and optimized. By processing 2.4 mL of sample, the enhancement factor was 39 and the sampling frequency was 50 h−1. For 30 s preconcentration time the detection limit was 0.3 μg L−1 and the relative standard deviation at 5.0 μg L−1 Cd concentration level was 2.9%. The calibration curve was linear in the range 0.8–40.0 μg L−1. The accuracy of the method was estimated by analyzing a certified reference material NIST-CRM 1643d (Trace elements in water). Good recoveries were obtained for spiked natural-water and waste-water samples. Correspondence: Aristidis N. Anthemidis, Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, GR-Thessaloniki 54124, Greece  相似文献   
8.
A simple, sensitive and powerful on-line sequential injection (SI) dispersive liquid-liquid microextraction (DLLME) system was developed as an alternative approach for on-line metal preconcentration and separation, using extraction solvent at microlitre volume. The potentials of this novel schema, coupled to flame atomic absorption spectrometry (FAAS), were demonstrated for trace copper and lead determination in water samples. The stream of methanol (disperser solvent) containing 2.0% (v/v) xylene (extraction solvent) and 0.3% (m/v) ammonium diethyldithiophosphate (chelating agent) was merged on-line with the stream of sample (aqueous phase), resulting a cloudy mixture, which was consisted of fine droplets of the extraction solvent dispersed entirely into the aqueous phase. By this continuous process, metal chelating complexes were formed and extracted into the fine droplets of the extraction solvent. The hydrophobic droplets of organic phase were retained into a microcolumn packed with PTFE-turnings. A portion of 300 μL isobutylmethylketone was used for quantitative elution of the analytes, which transported directly to the nebulizer of FAAS. All the critical parameters of the system such as type of extraction solvent, flow-rate of disperser and sample, extraction time as well as the chemical parameters were studied. Under the optimum conditions the enhancement factor for copper and lead was 560 and 265, respectively. For copper, the detection limit and the precision (R.S.D.) were 0.04 μg L−1 and 2.1% at 2.0 μg L−1 Cu(II), respectively, while for lead were 0.54 μg L−1 and 1.9% at 30.0 μg L−1 Pb(II), respectively. The developed method was evaluated by analyzing certified reference material and applied successfully to the analysis of environmental water samples.  相似文献   
9.
An optical capillary waveguide fluoroimmunosensor based on glass capillaries internally coated with an ultrathin poly(dimethylsiloxane) (PDMS) film is presented. The evaluation of the capillaries developed was done in comparison with aminosilanized [3-(aminopropyl)triethoxysilane, APTES] glass and poly(methylpentene) (PMP) capillaries by immobilizing rabbit γ-globulins on the internal capillary wall. Following reaction with (R)-phycoerythrin-labelled antibody, the capillary was scanned with a laser beam and the fluorescence waveguided through the capillary wall was detected by a photomultiplier placed at one of its ends. The capillaries developed provided considerably improved protein coating homogeneity (intracapillary coefficients of variation 2.9–6.6%) and repeatability (intercapillary coefficients of variation 2.1–5.0%) compared with APTES-treated ones (7.9–13.4 and 8.5–15.2%, respectively). With use of these capillaries in a sandwich-type immunosensor for the determination of rabbit γ-globulins, the assay detection limit was improved eightfold (4.4 ng/mL) compared with that obtained using PMP capillaries (35.3 ng/mL), whereas the assay repeatability was improved threefold (intra-assay coefficients of variation 5.9–13.1%) compared with APTES-treated capillaries (15.6–36%). Optoelectronic set-up used to scan the capillaries (left) and representative fluorescence scannings of dual-band poly(methylpentene) (PMP), PDMS-modified glass and APTES treated glass capillaries  相似文献   
10.
A novel, automatic on-line sequential injection dispersive liquid-liquid microextraction (SI-DLLME) method, based on 1-hexyl-3-methylimidazolium hexafluorophosphate ([Hmim][PF(6)]) ionic liquid as an extractant solvent was developed and demonstrated for trace thallium determination by flame atomic absorption spectrometry. The ionic liquid was on-line fully dispersed into the aqueous solution in a continuous flow format while the TlBr(4)(-) complex was easily migrated into the fine droplets of the extractant due to the huge contact area of them with the aqueous phase. Furthermore, the extractant was simply retained onto the surface of polyurethane foam packed into a microcolumn. No specific conditions like low temperature are required for extractant isolation. All analytical parameters of the proposed method were investigated and optimized. For 15 mL of sample solution, an enhancement factor of 290, a detection limit of 0.86 μg L(-1) and a precision (RSD) of 2.7% at 20.0 μg L(-1) Tl(I) concentration level, was obtained. The developed method was evaluated by analyzing certified reference materials while good recoveries from environmental and biological samples proved that present method was competitive in practical applications.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号