首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   13篇
  免费   0篇
化学   13篇
  2023年   1篇
  2022年   1篇
  2018年   1篇
  2007年   5篇
  2006年   2篇
  2003年   1篇
  2002年   2篇
排序方式: 共有13条查询结果,搜索用时 15 毫秒
1.
Two simple and sensitive spectrophotometric and fluorimetric methods for the determination of tranexamic acid in tablets are developed. The methods are based on condensation the primary amino group of tranexamic acid with acetyl acetone and formaldehyde producing a yellow coloured product, which is measured spectrophotometrically at 335 nm or fluorimetrically at 480 nm the colour was stable for at least 1 h. Beer's law was valid within a concentration rang of 0.05-2.0 microg ml-1 spectrophotometrically and 0.05-0.25 microg ml-1 fluorimetrically. All the variables were studied to optimize the reaction conditions. No interference was observed in the presence of common pharmaceutical excipints. The validity of both methods was tested by analyzing tranexamic acid in its pharmaceutical preparations. Good recoveries were obtained and the results were comparable with those obtained by standard method.  相似文献   
2.
Two sensitive and simple spectrophotometric methods are developed for the determination of trazodone HCl, famotidine, and diltiazem HCl in pure and pharmaceutical preparations. The methods are based on the oxidation of the cited drugs with iron(III) in acidic medium. The liberated iron(II) reacts with 1,10-phenanthroline (method A) and the ferroin complex is colorimetrically measured at 510 nm against reagent blank. Method B is based on the reaction of the liberated Fe(II) with 2,2-bipyridyl to form a stable colored complex with lambda(max )at 520 nm. Optimization of the experimental conditions was described. Beer's law was obeyed in the concentration range of 1-5, 2-12, and 12-32 microg mL(-1) for trazodone, famotidine, and diltiazem with method A, and 1-10 and 8-16 microg mL(-1) for trazodone and famotidine with method B. The apparent molar absorptivity for method A is 1.06x10(5), 2.9x10(4), 1.2x10(4) and for method B is 9.4x10(4 )and 1.6x10(4), respectively. The suggested procedures could be used for the determination of trazodone, famotidine, and diltiazem, both in pure and dosage forms without interference from common excipients.  相似文献   
3.
 The construction of a plasticised PVC matrix-type promazinium cation-selective membrane electrode and its use in the potentiometric determination of promazine hydrochloride in pharmaceutical preparations are described. It is based on the use of the ion-associate species, formed by promazinium cation and tetraphenylborate (TPB) counter ion. The basic electrode performance characteristics are evaluated according to IUPAC recommendations. It exhibited a linear response for 1 × 10−2−1 × 10−5 M of promazine hydrochloride solutions with a cationic Nernstian slope over the pH range 2–6. Common organic and inorganic cations showed negligible interference. Direct potentiometric determination of 1 × 10−2−1 × 10−5 M aqueous promazine hydrochloride using this membrane electrode system showed an average recovery of 99.5% with a mean standard deviation of 1.5%. This electrode was successfully used for monitoring the titration of promazine hydrochloride with sodium tetraphenyl borate and for determining promazine hydrochloride in ampoules. Received June 15, 2001 Revision November 6, 2001  相似文献   
4.
In this article, we report a methodology for the voltammetric behavior of meclizine hydrochloride at different nano modified electrodes e.g., Glassy carbon (GCE), pencil graphite (PGE), Carbon Nano tubes-carbon paste (CNTS-CPE) and Carbon Nano tubes-zinc oxide carbon paste (CNTS/ZnO-CPE) using cyclic and square wave voltammetry and the highest performance of them was CPE/CNTs/ZnO electrode and therefore was used as working electrode. The oxidation reaction mechanism of meclizine hydrochloride (MEC-HCL) is proposed to be one electron system. The results obtained with a square wave were linear over the concentration ranges 19.5–102.4 ng mL?1 with a correlation coefficient 0.998. The square wave technique showed a low of detectable (LOD) of 6.444 ng/mL and a limit of quantification (LOQ) of 19.530 ng/mL at CNTS/ZnO-CPE. Based on these findings, a simple and not time-consuming method was used for the analysis of MEC-HCL in pharmaceutics and biological fluids. The method showed a minimum detectability (LOD) of 0.02, 0.008 and 0.14 lg/mL and a limit of quantitation (LOQ) of 0.06, 0.02 and 0.42 lg/mL at PGE, CPE and GCE, respectively. The method was validated and compared with the reference valid method. It revealed good accuracy and reproducible results. The anticipated voltammetric procedure has the advantage of being simple, precise, inexpensive and highly sensitive.  相似文献   
5.
This paper describes three sensitive spectrophotometric and spectrofluorimetric methods for determination of ramipril in its pure form and pharmaceutical tablets. The first method is based on the oxidation of the drug with 1-chlorobenzotriazole reagent (CBT) in strong alkaline medium followed by measuring the absorbance at 350 nm. The method obeys Beer's law over concentration range 15-50 microg ml(-1). For the second and third, both are non-extractive methods based on the formation of ternary complex between copper (II), eosin and ramipril in the presence of methylcellulose as surfactant. Spectrophotometrically, under the optimum condition, the ternary complex showed an absorption maximum at 543 nm. The method obeys Beer's law over concentration range of 20-80 microg ml(-1). A fluorescence quenching method for the determination of ramipril by forming this ternary complex was also investigated for the propose of enhance the sensitivity of the determination. The methods are simple, sensitive, and accurate. The results obtained are reproducible with a coefficient of variation less than 2%. The proposed have been successfully applied to the assay of ramipril in tablets. The results compare favorably with official method.  相似文献   
6.
Picric acid, bromocresol green, bromothymol blue, cobalt thiocyanate and molybdenum(V) thiocyanate have been tested as spectrophotometric reagents for the determination of disopyramide and irbesartan. Reaction conditions have been optimized to obtain coloured comoplexes of higher sensitivity and longer stability. The absorbance of ion-pair complexes formed were found to increases linearity with increases in concentrations of disopyramide and irbesartan which were corroborated by correction coefficient values. The developed methods have been successfully applied for the determination of disopyramide and irbesartan in bulk drugs and pharmaceutical formulations. The common excipients and additives did not interfere in their determination. The results obtained by the proposed methods have been statistically compared by means of student t-test and by the variance ratio F-test. The validity was assessed by applying the standard addition technique. The results were compared statistically with the official or reference methods showing a good agreement with high precision and accuracy.  相似文献   
7.
Thin-layer chromatography, first derivative, ratio spectra derivative spectrophotometry and Vierordt's method have been developed for the simultaneous determination of paracetamol and drotaverine HCl. TLC densitometric method depends on the difference in Rf values using ethyl acetate:methanol:ammonia (100:1:5 v/v/v) as a mobile phase. The spots of the two drugs were scanned at 249 and 308 nm over concentration ranges of 60-1200 microg/ml and 20-400 microg/ml with mean percentage recovery 100.11%+/-1.91 and 100.15%+/-1.87, respectively. The first derivative spectrophotometric method deals with the measurements at zero-crossing points 259 and 325 nm with mean percentage recovery 99.25%+/-1.08 and 99.45%+/-1.14, respectively. The ratio spectra first derivative technique was used at 246 and 305 nm with mean percentage recovery 99.75%+/-1.93 and 99.08%+/-1.22, respectively. Beer's law for first derivative and ratio spectra derivative methods was obeyed in the concentration range 0.8-12.8 and 0.4-6.4 microg/ml of paracetamol and drotaverine HCl, respectively. Vierordt's method was applied to over come the overlapping of paracetamol and drotaverine HCl in zero-order spectra in concentration range 2-26 and 2-40 microg/ml respectively. The suggested methods were successfully applied for the analysis of the two drugs in laboratory prepared mixtures and their pharmaceutical formulation. The validity of the methods was assessed by applying the standard addition technique. The obtained results were statistically agreed with those obtained by the reported method.  相似文献   
8.
Simple and sensitive spectrophotometric and spectrofluorimetric methods are described for analysis of acyclovir and acebutolol hydrochloride. The proposed methods are based on oxidation of the selected drugs with cerium(IV) ion in acidic medium with subsequent measurement of either the decrease in absorbance at 320nm or the fluorescence intensity of the produced cerous(III) ion at 361-363nm (excitation at 250nm). Beer's law obeyed from 2 to 8, 0.25 to 2.5microgcm-1 acyclovir, 1 to 7 and 0.25 to 2.5microgml-1 acebutolol hydrochloride, using the spectrophotometric and spectrofluorimetric method, respectively. The proposed method were successfully applied for determination of the selected drugs in their pharmaceutical preparations with good recoveries.  相似文献   
9.
Simple and sensitive spectrophotometric and spectrofluorimetric methods are described for analysis of acebutolol hydrochloride. The proposed methods are based on oxidation of the selected drug with cerium(IV) ion in acidic medium with subsequent measurement of either the decrease in absorbance at 320 nm or the fluorescence intensity of the produced cerous(III) ion at 363 nm (excitation at 250 nm). Beer's law obeyed from 1.0-7.0 microg ml(-1) and 0.25-2.5 microg ml(-1) acebutolol hydrochloride, using the spectrophotometric and spectrofluorimetric method, respectively. The proposed methods were successfully applied for determination of the selected drug in its pharmaceutical preparation with good recoveries.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号