排序方式: 共有28条查询结果,搜索用时 0 毫秒
1.
Based on scalar diffraction theory, 8-phase-level 256×256 elements diffractive microlens array with element dimension of 50×33 μm2 have been fabricated on the back-side of PtSi(3~5 μm) infrared CCD. The measurement results indicated that the ratio of the signal-to-noise of the infrared CCD with microlens was increased by a factor of 2.8. 相似文献
2.
3.
4.
本文利用吸附曲线及电化学的方法,研究了一系列抑制剂在银及溴化银上的吸附行为,将这些吸附性质与显影过程中相应的抑制剂存在时的显影结果对比,实验表明:只有当抑制剂在银上为中等的吸附,而在溴化银上吸附很小时,才可能利用抑制剂达到高反差。相应的机理及抑制剂在银上的吸附性质在文中也作了讨论。 相似文献
5.
ZnO不仅是极其重要的半导体材料,而且还广泛用做化学反应的催化剂,光催化剂和光电转换材料。近年来,ZnO纳米粒子的制备和应用得到了广泛的研究,但许多问题并不十分清楚。譬如,对ZnO颗粒的可见荧光的发生机制就众说纷纭。Henglein等认为ZnO可见荧光由ZnO颗粒表面的阴离子空位引起,而Bahnemann等却认为可见荧光由被捕获的光生电子向被捕获的空穴越迁而引起。本文通过微量水对ZnO超微粒的荧光的影响的研究,进一步阐明ZnO荧光的产生机理。结果支持了Bahnemann的观点。 相似文献
6.
由于半导体超微粒子具有独特的尺寸量子化效应和表面效应[1~6],它在利用太阳能光催化降解有机污染物,有机光合成及光电转化等领域中有着极其广泛的应用.目前,大量的工作集中在超微颗粒表面上有机物的光反应过程的研究[7]. 相似文献
7.
乙醇溶液中ZnO纳米粒子的形成机理研究 总被引:6,自引:1,他引:6
半导体纳米粒子的研究是当今材料科学及物理化学的热门课题[1-3].由于纳米粒子具有极大的比表面、尺寸量子化效应及增强的氧化和还原能力等不同于扶林的特殊性质,它被广泛地用于光催化,光电材料的制备及非线性光学材料的研究等[4-6].ZnO作为一种重要的半导体材料,其纳米粒子的制备近年来也有报导[7-14].由于ZnO在水中的生成自由能较正,所以一般都在醇溶液中制备,但其具体的成核机理至今并不十分清楚.本工作通过仔细的研究,阐明了ZnO纳米粒子形成过程中的成核和生长机理.1实验部分醋酸锌,氢氧化钠和乙醇均为分析纯试剂.制… 相似文献
8.
9.
金属和半导体纳米粒子的制备及性质的研究是当今材料科学和物理化学的热门课题[1-6].在利用太阳能光降解环境污染物、生物传感器以及光生物等方面这些纳米粒子都具有实际应用的可能性.对纳米粒子表面进行修饰而形成的复合纳米粒子可以有效地调整单一颗粒的表面性质甚至颗粒的稳定性.另外,复合纳米粒子的制备对研究纳米粒子的尺寸量子化效应、非线性光学性质及其它光电性质都有重要的意义.人们已成功地制备了许多复合金属-金属纳米粒子,如Cu-Ag[7],Ag-Pd[8]及Ag-Pt[9]等.关于复合半导体-半导作纳米粒子也有报导,如C… 相似文献
10.
Spectroscopic measurements and terahertz imaging of the cornea using a rapid scanning terahertz time domain spectrometer 下载免费PDF全文
Spectroscopic measurements and terahertz imaging of the cornea are carried out by using a rapid scanning terahertz time domain spectroscopy(THz-TDS) system.A voice coil motor stage based optical delay line(VCM-ODL) is developed to provide a rather simple and robust structure with both the high scanning speed and the large delay length.The developed system is used for THz spectroscopic measurements and imaging of the corneal tissue with different amounts of water content,and the measurement results show the consistence with the reported results,in which the measurement time using VCM-ODL is a factor of 360 shorter than the traditional motorized optical delay line(MDL).With reducing the water content a monotonic decrease of the complex permittivity of the cornea is observed.The two-term Debye relaxation model is employed to explain our experimental results,revealing that the fast relaxation time of a dehydrated cornea is much larger than that of a hydrated cornea and its dielectric behavior can be affected by the presence of the biological macromolecules.These results demonstrate that our THz spectrometer may be a promising candidate for tissue hydration sensing and practical application of THz technology. 相似文献