首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   137篇
  免费   9篇
  国内免费   4篇
化学   35篇
力学   1篇
数学   3篇
物理学   65篇
综合类   46篇
  2023年   3篇
  2022年   5篇
  2021年   3篇
  2020年   4篇
  2017年   3篇
  2016年   4篇
  2015年   6篇
  2014年   14篇
  2013年   13篇
  2012年   10篇
  2011年   7篇
  2010年   6篇
  2009年   10篇
  2008年   11篇
  2007年   6篇
  2006年   7篇
  2005年   7篇
  2004年   8篇
  2003年   1篇
  2002年   5篇
  2000年   5篇
  1999年   2篇
  1998年   1篇
  1997年   1篇
  1996年   1篇
  1995年   2篇
  1994年   1篇
  1990年   1篇
  1988年   2篇
  1987年   1篇
排序方式: 共有150条查询结果,搜索用时 31 毫秒
91.
A new approach for monitoring the state of conservation of cultural heritage objects surfaces is being developed. The technique utilizes multi-spectral imaging, multivariate analysis and statistical process control theory for the automatic detection of a possible deterioration process, its localization and identification, and the wavelengths most sensitive to detecting this before the human eye can detect the damage or potential degradation changes occur. A series of virtual degradation analyses were performed on images of parchment in order to test the proposed algorithm in controlled conditions. The spectral image of a Dead Sea Scroll (DSS) parchment, IAA (Israel Antiquities Authority) inventory plate # 279, 4Q501 Apocryphal Lamentations B, taken during the 2008 Pilot of the DSS Digitization Project, was chosen for the simulation.  相似文献   
92.
Experimental studies of thermal effects in high-intensity focused ultrasound (HIFU) procedures are often performed with the aid of fine wire thermocouples positioned within tissue phantoms. Thermocouple measurements are subject to several types of error which must be accounted for before reliable inferences can be made on the basis of the measurements. Thermocouple artifact due to viscous heating is one source of error. A second is the uncertainty regarding the position of the beam relative to the target location or the thermocouple junction, due to the error in positioning the beam at the junction. This paper presents a method for determining the location of the beam relative to a fixed pair of thermocouples. The localization technique reduces the uncertainty introduced by positioning errors associated with very narrow HIFU beams. The technique is presented in the context of an investigation into the effect of blood flow through large vessels on the efficacy of HIFU procedures targeted near the vessel. Application of the beam localization method allowed conclusions regarding the effects of blood flow to be drawn from previously inconclusive (because of localization uncertainties) data. Comparison of the position-adjusted transient temperature profiles for flow rates of 0 and 400 ml/min showed that blood flow can reduce temperature elevations by more than 10%, when the HIFU focus is within a 2 mm distance from the vessel wall. At acoustic power levels of 17.3 and 24.8 W there is a 20- to 70-fold decrease in thermal dose due to the convective cooling effect of blood flow, implying a shrinkage in lesion size. The beam-localization technique also revealed the level of thermocouple artifact as a function of sonication time, providing investigators with an indication of the quality of thermocouple data for a given exposure time. The maximum artifact was found to be double the measured temperature rise, during initial few seconds of sonication.  相似文献   
93.
Semiconductor electronic and optoelectronic devices such as transistors, lasers, modulators, and detectors are critical to the contemporary computing and communications infrastructure. These devices have been optimized for efficiency in power consumption and speed of response. There are gaps in the detailed understanding of the internal operation of these devices. Experimental electrical and optical methods have allowed comprehensive elaboration of input–output characteristics, but do not give spatially resolved information about currents, carriers, and potentials on the nanometer scale relevant to quantum heterostructure device operation. In response, electrical scanning probe techniques have been developed and deployed to observe experimentally, with nanometric spatial resolution, two-dimensional profiles of the electrical resistance, capacitance, potential, and free carrier distribution, within actively driven devices. Experimental configurations for the most prevalent electrical probing techniques based on atomic force microscopy are illustrated with considerations for practical implementation. Interpretation of the measured quantities are presented and calibrated, demonstrating that internal quantities of device operation can be uncovered. Several application areas are examined: spreading resistance and capacitance characterization of free carriers in III-V device structures; acquisition of electric potential and field distributions of semiconductor lasers, nanocrystals, and thin films; scanning voltage analysis on diode lasers—the direct observation of the internal manifestations of current blocking breakdown in a buried heterostructure laser, the effect of current spreading inside actively biased ridge waveguide lasers, anomalously high series resistance encountered in ridge lasers—as well as in CMOS transistors; and free-carrier measurement of working lasers with scanning differential spreading techniques. Applications to emerging fields of nanotechnology and nanoelectronics are suggested.  相似文献   
94.
Gelman and Bloom found that adults and children's object naming was sensitive to how an object was created (man-made or not), but they did not reveal on which specific level of conceptual system this effect was. Using a free-naming task and a force-choice task, two experiments were conducted to test a hypothesis that this effect was specifically on domain level ("artifact/non-artifact" distinction), in Experiment 1, participants were asked to name shortly-depicted objects, rate their confidence, and report their reasons for each naming response. Resuits showed that most of the naming responses in "man-made" condition were in artifact domain, and most in "natural" condition were in non-artifact domain, although in both conditions names were very divergent on basic level. In Experiment 2, another group of participants were asked to choose one from two names (one in artifact domain and the other in non-artifact domain) to match the same shortly-depicted objects presented in the first experiment. Results of Experiment 1 on domain level were replicated in Experiment 2. These convergent findings supported the hypothesis that the effect of object's origin is specifically on domain level of conceptual system of objects. Reasons explicitly reported for naming responses in Experiment 1 suggested that participants might automatically infer objects' functions in "man-made" condition but not in "natural" condition. Here the function-based hypothesis of artifacts classification is discussed.  相似文献   
95.
In continuous wave (CW) electron paramagnetic resonance imaging (EPRI), high quality of reconstruction in a limited acquisition time is a high priority. It has been shown for the case of 3D EPRI, that a uniform distribution of the projection data generally enhances reconstruction quality. In this work, we have suggested two data acquisition techniques for which the gradient orientations are more evenly distributed over the 4D acquisition space as compared to the existing methods. The first sampling technique is based on equal solid angle partitioning of 4D space, while the second technique is based on Fekete points estimation in 4D to generate a more uniform distribution of data. After acquisition, filtered backprojection (FBP) is applied to carry out the reconstruction in a single stage. The single-stage reconstruction improves the spatial resolution by eliminating the necessity of data interpolation in multi-stage reconstructions. For the proposed data distributions, the simulations and experimental results indicate a higher fidelity to the true object configuration. Using the uniform distribution, we expect about 50% reduction in the acquisition time over the traditional method of equal linear angle acquisition.  相似文献   
96.
针对工件识别问题,提出了一种应用支持向量机(Support Vector Machine,SVM)与组合矩对工件进行识别的方法;通过对提取图像的Hu不变矩进行处理,形成利用组合矩进行工件识别的新方法;改进后的算法降低了特征维数,缩减了识别时间,提高了识别准确率;结合试验比较了两种方法的分类效果,其中提取Hu不变矩作为特征的识别率为82.3%,而采用组合矩作为特征的识别率高达94.1%,高于Hu不变矩作为特征的识别率.  相似文献   
97.
The study on material properties of ancient stone or jade artifacts is essential to trace the trade routes of raw materials, the tools used to making them, and moreover the social function of the artifacts. In present research, we focused on 23 intact samples that were made of versatile rocks. These samples dated from 5000 bc to 771 bc were unearthed from the Yellow River and Yangtze River basins in China. Based on the analytical results of confocal laser micro‐Raman spectroscopy, 14 minerals consisted of these rocks such as muscovite, antigorite, calcite, quartz, diopside, turquoise, corundum, and sillimanite were identified. The obtained scientific information about their primary material properties helps us to better understand their social functions and technologically related issues. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   
98.
A total of 14 pieces of ancient jade artifact unearthed from Henan Province were non-destructively analyzed by means of a portable X-ray fluorescence spectrometer (pXRF), laser Raman spectroscopy (portable and mobile) and optical coherence tomography (OCT) technology, comprehensively. The raw materials of ancient jade artifacts could be determined accurately through the combination of pXRF and portable Raman spectrometer in a short time. With the advantages of small size and easy-operation, these two instruments are suitable to in situ non-destructive analysis of ancient jade artifacts. The results of the pXRF shows that these ancient jade artifacts can be divided into 6 categories such as rich in Si Al K, rich in Ca, rich in Si Ca, rich in Si Mg, rich in Si, rich in Ca P. Their main phases have been successfully identified by the portable Raman spectrometer. In the lab, the mobile confocal laser Raman spectrometer, which help us find the Raman vibration peak of [OH] in the tremolite jade, is used to make up the disadvantages of the portable Raman spectrometer such as lower spectral resolution, lower accuracy and narrower measuring range. We can use the OCT to analyze the transparency, fiber fineness and inclusion etc. of the jade artifacts. The confocal laser Raman spectroscopy combined with OCT is used to analyze 2 containing inclusion of tremolite jade samples. OCT image can visually display the distribution characteristics of the inclusion in these 2 samples. Confocal laser Raman spectroscopy can accurately locate the sample surface of inclusion, then we can observe the micro morphology and analyze its phase. The results show that the black inclusion is graphite. This work is very significant to study the geographical origin of jade. Through the study we find, the use of OCRF, laser Raman spectroscopy (portable and mobile) and OCT can be achieved on the identification and analysis of cultural relic's phase composition and texture feature and meet the basic requirements of field archaeological work analysis.  相似文献   
99.
魏星  闫镔  张峰  李永丽  席晓琦  李磊 《物理学报》2014,63(5):58702-058702
针对多金属伪影的校正问题,本文通过仿真实验分析了多金属伪影的成因,并提出了一种基于投影校正的多金属伪影校正方法.该方法首先直接从投影域分割出金属区域,然后建立对金属区域投影值的校正模型,最后通过调整模型参数达到校正目的.模型以重建图像的灰度熵为目标函数,采用单纯形法迭代求解使熵最小时的校正参数.仿真和实际数据的实验结果表明,本文算法对多金属伪影的校正起到了良好的效果,且校正后的图像质量优于插值校正法.  相似文献   
100.
梯度回波序列是磁共振成像中常用的脉冲序列,然而梯度回波对主磁场波动非常敏感,呼吸等生理运动引起的信号波动会导致图像伪影.该文报道了采用导航回波技术获取呼吸运动导致的局部磁场波动,用以矫正图像回波中随时间变化的相位波动,并将该技术应用于三维多回波梯度回波成像和T2*定量图研究.研究结果显示:矫正前,相位波动幅度随回波时间增长而增大,模图和T2*定量图在相位编码方向有明显伪影,并且男女呼吸伪影水平有显著性差异;矫正后,相位波动幅度大幅下降,图像伪影水平有显著性下降.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号