The microstructure of a diblock copolymer dispersed in nanorod arrays grafted on a plate are investigated via annealing MC simulation. The confinement in nanorod arrays provides a complex confined space which leads to complicated microphase separation structures. Different morphologies of top and bottom of the film in the nanorod arrays are observed by varying the inducing height of nanorod and its grafting density in the bottom. Due to a short inducing range by the nanorods, the top structures are therefore mainly dominated by the competition between the absolute height of off‐induced layer on the top and the nature of block copolymer itself; while the bottom structures are affected by the symmetry of block copolymer and the gap among rods.
High‐precision on‐line procedure for measurement of calcium isotopic ratio by coupling ion chromatography to multicollector inductively coupled plasma mass spectrometry was developed. Calcium separation from the sample matrix was achieved on an ion chromatography column—IonPac CS16—ID 3 mm connected with CERS 500 2 mm suppressor and followed by multicollector inductively coupled plasma mass spectrometry calcium isotopic ratio determination. Dry plasma mode was used with Aridus II desolvation system. To sustained samples with high level of total dissolved salts as well as account capacity of applied analytical column, the method has been optimized regarding calcium isotope ratio measurements with low‐resolution mass spectrometry. Mass discrimination and instrument drift were corrected by sample‐standard bracketing method using the 44Ca/42Ca isotope ratio of SRM 915a as a standard. Good accuracy and reasonable precision of calcium isotope ratio (generally 0.20‰ [2SD]) were achieved, which are comparable to off‐line Ca separation and continuous measurement. The reproducibility of the proposed analytical procedure was verified by measuring the SRM 915a standard as a sample randomly over 3 months (n = 56). Applicability of the protocol was demonstrated for matrix‐rich natural water samples, coral samples, and bone standard reference materials. 相似文献
为了在汽车意外事故后伤者能得到及时的救援, 设计了一种基于嵌入式的汽车事故求救系统。该系统以MC9S12XS128为主控芯片, 利用三轴加速传感器MPU6050和GPS(Global Positioning System)判断车辆的姿态信息和位置信息, 并通过GSM(Global System for Mobile Communications)模块将车况数据传给呼叫中心和家
属端, 接收端对事故确认后迅速救援。测试结果证明了该系统的可靠性。 相似文献
Microcystins (MC) are cyanobacterial hepatotoxins responsible for animal-poisoning and human health incidents. Immunoassays provide a sensitive and fast means to detect these toxins, but cross-reactivity (CR) characteristic of different antibodies was variable. Here, we have produced and characterized a monoclonal antibody (Clone MC8C10) with highly specificity against the most frequent and most toxic variant of microcystins, MC-LR. MC8C10 is more specific against MC-LR among the reported antibodies before. The immunogen was synthesized from the modified MC-LR and bovine serum albumin (BSA). An indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) with MC8C10 was established to detect the MCs in waters, which showed highly specificity with MC-LR, and have a detection limit for MC-LR 0.1 μg L−1, the 50% inhibition concentration (IC50) for MC-LR was 1.8 ± 0.1 μg L−1 and the quantitative detection range was from 0.3 to 10 μg L−1. The [4-arginine] microcystins and the nodularin-R showed lower cross-reactivates (CR < 10%), and other MCs such as MC-LF and MC-LW are not recognized (CR < 10−4). The analysis results of real water samples with ic-ELISA showed that all the coefficients of variation were less than 15%, and the recovery was (100.3 ± 5.9)%. So the highly specific ic-ELISA will commendably suit for sensitive analysis for MC-LR in surface water as well as drinking water. 相似文献