首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   129篇
  免费   5篇
  国内免费   5篇
化学   121篇
晶体学   2篇
力学   4篇
物理学   12篇
  2023年   2篇
  2022年   4篇
  2021年   10篇
  2020年   3篇
  2019年   4篇
  2017年   2篇
  2016年   4篇
  2015年   6篇
  2014年   4篇
  2013年   9篇
  2012年   7篇
  2011年   14篇
  2010年   2篇
  2009年   12篇
  2008年   5篇
  2007年   4篇
  2006年   11篇
  2005年   8篇
  2004年   10篇
  2003年   5篇
  2002年   4篇
  2000年   1篇
  1998年   1篇
  1996年   3篇
  1995年   1篇
  1993年   3篇
排序方式: 共有139条查询结果,搜索用时 15 毫秒
11.
The effects of urban and indoor air pollution on human health are a major environmental concern for all, but not much has been researched in the developing world. Specifically, quantitative data on the occurrence of volatile organic compounds (VOCs) – main contributors to air pollution – in Asia and Africa are scarce compared to the availability of data in the developed world. This paper presents one of the first studies focusing on the analysis and occurrence of VOCs in Vietnam and Ethiopia, which constitutes part of the novelty of this work. A spectrum of 34 VOCs was measured at eight different urban sites in Ghent (Belgium), Hanoi (Vietnam), Jimma and Addis Ababa (Ethiopia) during three sampling campaigns from September 2008 to September 2010. Sampling was done in an active way by means of sorbent tubes filled with Tenax TA. The analysis was done by TD-GC-MS using internal standard calibration. Data were interpreted and compared in terms of (i) individual, subgroup and total VOCs concentration (TVOCs), (ii) indoor-to-outdoor (I/O) concentration ratios, (iii) source identification by diagnostic ratio and/or correlation coefficients, and (iv) ozone formation potential (OFP) at outdoor sites based on up-to-date maximum incremental reactivity (MIR). I/O concentration ratios varied between 0.2 and 30, with big differences noticed with respect to the type of VOC(s) considered and the type of outdoor sampling location. The highest TVOC concentrations were measured in street samples with maximum values of 54?µg/m3 in Ghent, 507?µg/m3 in Hanoi and 318?µg/m3 in Addis Ababa illustrating the large difference in ambient air quality levels. This is also reflected in the arithmetic mean OFP values (µg/m3) of 82, 1308 and 596 in Ghent, Hanoi and Addis Ababa, respectively. Results of this study could be helpful to support formulation of national policy with regard to ambient air quality.  相似文献   
12.
首先, 在碱性条件下, 不使用表面活性剂, 采用St?ber小球法以正硅酸四乙酯(TEOS)和正硅酸四丙酯(TPOS)为硅源, 生成初级氧化硅球形颗粒; 然后, 使酚醛树脂(间苯二酚和甲醛)与球形氧化硅的羟基共缩合形成酚醛树脂-氧化硅复合材料; 最后, 经高温碳化和酸蚀获得了空心碳纳米球(HCNSs). 通过调节TEOS/TPOS的摩尔比获得了一系列具有良好的单分散性且粒径、 壁厚可调节的HCNSs, 其粒径和壁厚分别在280~430 nm和15~63 nm的范围内. 仅以TPOS为硅源时合成的HCNS-0/4具有较大的粒径(426 nm)和壁厚(63 nm)、 较高的比表面积(1216 m2/g)和孔容(0.508 cm3/g), 并且具有较大的挥发性有机化合物(VOCs)吸附性能, 其正己烷、 甲苯和油气的静态吸附容量分别为2.02, 1.42和0.926 g/g, 正己烷和甲苯的动态吸附容量分别为2.01 g/g和1.37 g/g, 均远高于商业化活性炭.  相似文献   
13.
Mesoporous Ce0.75Zr0.25O2 solid solution powders were successfully synthesized by a co-precipitation method. A combination of 10 wt% copper oxide, manganese oxide, and nickel oxide was added to the Ce0.75Zr0.25O2 support by impregnation method and calcined in the air with a flow rate of 2 ml s?1 at 400 °C for 4 h. All catalysts were characterized using Hydrogen Temperature Programmed Reduction (H2-TPR), X-ray Diffraction (XRD), and Brunauer-Emmet-Teller (BET) isotherm methods to find the interaction between metals, the crystallinity of the catalyst, surface area and pore volume of the catalyst, respectively. The 3.3% CuO-3.3% MnO2-3.3% NiO/Ce0.75Zr0.25O2 catalyst showed higher catalytic activity for benzene oxidation with benzene conversion of 90% at 250 °C and weight hourly space velocity (72,000 mL g?1 h?1) when compared to one metal oxide only. This finding presents a high activity and low-cost catalysts for removing a very lean concentration of benzene containing in the industrial flue gas at low temperatures.  相似文献   
14.
本研究以亲油性的双面胶作为基底,利用滴涂二乙炔单体结合紫外光聚合来制备均匀的聚二乙炔(PDA)薄膜,通过荧光和颜色两种信号变化模式(即"双模光学检测")研究了PDA薄膜对VOC气体的响应性,发现制备的PDA薄膜在2 min内就可以实现明显的荧光和颜色变化,有效解决了目前PDA薄膜在VOC气体检测方面存在响应速度慢、薄膜均一性差等问题.此外,为解决单一PDA薄膜的交叉响应性问题,本研究制备了四种不同的基于双面胶基底的PDA薄膜,并将制备的4种PDA薄膜集成到一片PDMS薄膜基底上来构建柔性的传感阵列,利用阵列的颜色变化结合模式识别技术,实现了对8种VOC气体的快速、灵敏区分.进一步将制备的PDA薄膜阵列用于健康人、模拟糖尿病及肾病患者呼出气体中VOC标志物的辨别和分析研究,发现可以将三类人的呼出气体清晰地区分,说明了该阵列在呼气疾病诊断中的应用前景.与目前报道的PDA薄膜阵列相比,本研究中基于双面胶基底的PDA薄膜阵列具有气体响应速度快、灵敏性高、柔韧性好、制备工艺简单、成本低、易于大规模制备等优点,有望用于实VOC气体检测研究中.  相似文献   
15.
Kim KH  Oh SI  Choi YJ 《Talanta》2004,64(2):518-527
This study was undertaken to establish one of the most reliable sampling methods and to precisely evaluate the bias involved in the collection of airborne pollutant samples. For the purpose of our study, we investigated the performance of three different types of sampling techniques by measuring major aromatic volatile organic compounds (VOC) in outdoor air; the target analytes specifically include benzene, toluene, ethylbenzene, and xylene (commonly called BTEX). As the first step of our approach, we designed and developed a multi-channel sampling system consisting of a six-port mass flow controller (SJU-MFC) system. Because this system allowed the collection of up to six replicate samples, our measurement results were analyzed and screened statistically for the derivation of high-quality BTEX data. The feasibility of this sampling system was further tested through a comparison with concurrent measurement data sets obtained by two additional, but independent, sampling techniques: (1) automatic continuous sampler (ACS) and (2) on-line GC (O-GC) system. Based on the data sets collected concurrently by three different sampling methods, we attempted to evaluate the compatibility of sampling techniques. Although the results obtained by SJU-MFC system were not statistically different from those of the O-GC system, they were moderately distinguishable from those of ACS. Such patterns were seen consistently, when examined by correlation analysis. The overall results of our study thus generally point out that the compatibility of data sets, when the proper caution is taken, improve significantly among different sampling methodologies.  相似文献   
16.
Using HMDS as catalyst for the trimerization of isocyanates presents many advantages as the expected isocyanurate is not contaminated by the catalyst or other side-products resulting from its degradation. In addition, HMDS presents a low toxicity, and is compatible with industrial applications. This article describes the hexamethyldisilazane (HMDS)-catalyzed trimerization of octylisocyanate. Experimental investigations and mechanistic considerations indicate that the true catalyst of the trimerization is trimethylsilyloctylamine, which results from the preliminary condensation of HMDS with octylisocyanate.  相似文献   
17.
A novel Hadamard transform-gas chromatography/mass spectrometry (HT-GC/MS) system equipped with on-line sample collection systems is described. A Hadamard-injector was successfully designed and then coupled with an on-line adsorption/desorption system for detecting volatile organic compounds (VOCs) and a supercritical fluid extraction (SFE) system, respectively, by HT-GC/MS. Six VOCs and three pesticides were used as model compounds. In the former case, an activated-charcoal trap was used to trap VOCs from the indoor air. After 10 L of indoor air had passed through the trap, the condensed components were heated and simultaneously injected into the GC column through the Hadamard-injector, based on Hadamard codes. In a second experiment, a sample of rice was spiked with three types of pesticides and the sample then extracted using a commercially available supercritical fluid extractor. After extraction, the extracted components were transferred to a holding tank and simultaneously injected into the GC column also using the Hadamard-injector. The findings show that, in both cases, the combination of on-line sample collection methods and the use of the Hadamard transform resulted in improved sensitivity and detection. Compared to the single injection used in most GC/MS systems, the signal-to-noise (S/N) ratios were substantially improved after inverse Hadamard transformation of the encoded chromatogram.  相似文献   
18.
19.
For the quantitative analysis of ‘compounds lacking authentic standards or surrogates’ (CLASS) in environmental media, we previously introduced an effective carbon number (ECN) approach to develop an empirical equation for the prediction of their response factor (RF). In this research, a series of laboratory experiments were carried out to benchmark the reliability of an ECN approach for sorbent tube/thermal desorption/gas chromatography (GC)/mass spectrometry (MS) applications. First, the ECN values were determined using external calibration data from 25 reference volatile organic compounds (VOCs) using two MS dectectors (quadrupole (Q) and time-of-flight (TOF)). Then, a certified standard mixture of 54 VOCs was analyzed by each system as a simulated unknown sample. The analytical bias, assessed in terms of percentage difference (PD) between the certified and ECN-predicted mass values, averaged 19.2 ± 16.1% (TOF-MS) and 28.2 ± 27.6% (Q-MS). The bias using a more simplified carbon number (CN)-based prediction increased considerably, yielding 53.4 ± 53.3% (TOF-MS) and 61.7 ± 81.3% (Q-MS). However, the bias obtained using the ECN-based prediction decreased significantly to yield average PD values of 9.84 ± 7.28% (TOF-MS) and 16.8 ± 8.35% (Q-MS), if the comparison was limited to 26 (out of 54) VOCs with CN ≥ 4 (i.e., 25 aromatics and hexachlorobutadiene).  相似文献   
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号