Fused silica capillaries deactivated with D4 and coated with OV-1 were subjected to cobalt-60 gamma radiation in order to elucidate the effect of incident radiation on column performance. The chromatographic performance of these open tubular columns in which OV-1 was polymerized in situ was found to be dependent on the dosage of radiation and was evaluated before and after the irradiated columns were rinsed with solvent. Of the radiation dosages employed, 3 MRad produced superior chromatographic performance coupled with very favorable residual surface activity. 相似文献
Angle-resolved photoelectron spectra were measured for a single-domain monolayer film of naphthalene-1,4,5,8-tetracarboxylic dianhydride (NTCDA) prepared on a cleaved GeS(0 0 1) surface using synchrotron radiation. The observed photoelectron angular distributions were analyzed by a calculation using the single-scattering approximation combined with molecular orbital calculation. With the help of the low-energy electron diffraction pattern, the structure of the NTCDA monolayer on GeS(0 0 1) was estimated quantitatively. 相似文献
The effects of60Co-gamma radiation and of various sample composition on the reduction of hematite to iron in the graphite-iron(III) oxide system in air were studied using isothermal and dynamic TG techniques. Kinetic analysis of isothermal data were performed according to various theoretical models of heterogeneous reactions and the results showed that the three-dimensional phase boundary model gives the best fit of data. Analysis of dynamic TG data were made using Ozawa integral method, Coats-Redfern method and a composite method based on the modified Coats and redfern equation. The activation parameters were calculated and the results of the different methods were compared and discussed.Radiation apparently did not introduce a change in the reaction model or mechanism. However, there is a decrease in activation energy and frequency factor upon irradiation and a decrease in the half-life time of the reaction which is remarkable at the higher temperatures and higher doses.
Zusammenfassung Mittels isothermer und dynamischer TG wurde im Graphit-Eisen(III)oxidsystem in Luft der Einfluß von60Co-Gammastrahlung und von verschiedenen Probenzusammensetzungen auf die Reduktion von Hämatit zu Eisen untersucht. Entsprechend verschiedener theoretischer Modelle heterogener Reaktionen wurde eine kinetische Analyse der isothermen Daten durchgeführt und die Ergebnisse zeigten, daß das dreidimensionale Phasengrenzenmodell die beste Übereinstimmung liefert. Die Analyse der dynamischen TG-Daten wurde mittels der Integralmethode von Ozawa, der Coats-Redfem-Methode und einer zusammengesetzten Methode auf der Grundlage der modifizierten Coats und Redfern Gleichung durchgeführt. Die Aktivierungsparameter wurden berechnet und die Ergebnisse der verschiedenen Methoden miteinander verglichen und diskutiert.Strahlung scheint keine Änderung des Reaktionsmodelles oder des Mechanismus hervorzurufen. Durch Bestrahlung gibt es aber ein Absinken der Aktivierungsenergie und des Frequenzfaktors sowie ein Absinken der Halbwertszeit der Reaktion, was bei höheren Temperaturen und höherer Dosis bemerkenswert groß ist.
The high microbial load of fresh and dry natural casings increases the risk of meat product contamination with pathogenic microorganisms, agents of foodborn diseases.
The aim of this work is to evaluate the killing effect of gamma radiation of the resident microbial population of pork and beef casings, to improve their hygiene and safety.
Portions of fresh pork (small intestines and colon) and dry beef casings were irradiated in a Cobalt 60 source with with absorbed doses of 1,2,5 and 10 kGy.
The D10 values of total aerobic microorganisms in the pork casings were 1.65 kGy for colon and 1.54 kGy for small intestine. The D10 value found in beef dry casings (small intestine) was 10.17 kGy. Radurization with 5 kGy was able to reduce, at least, 6 logs the coliform bacteria in pork casings. The killing effect over faecal Streptococci was 4 logs for pork fresh casings and 2 logs for beef dry casings. Gamma radiation with 5 kGy proved to be a convenient method to reduce substantially the microbial population of pork fresh casings. Otherwise, the microbial population of beef dry casings still resisted to 10 kGy. 相似文献
The present work discusses the grafting by electron beam irradiation of poly(ethylene oxide) (PEO) star-shaped polymers onto porous expanded polytetrafluoroethylene (EXPTFE) surfaces. The resulting materials are intended to combine the good biocompatible properties of PEO with the outstanding mechanical properties of PTFE. The star-shaped PEOs were synthesized via anionic polymerization. 3 Mev electron beam irradiation was applied to graft these PEO stars onto porous EXPTFE surfaces. The hydrophobic EXPTFE surface had to be pre-modified with N-vinylpyrrolidone. ESCA was used to quantify the amount of grafted star-shaped PEO. Unmodified EXPTFE surfaces are well known, when implanted in a body, to be rapidly covered by a layer of cells and fibrin. The EXPTFE coated with PEO were implanted in the peritoneal cavity of rats (or under the back skin). This implantation did not induce any inflammation reactions and SEM analysis had attested the absence of adsorbed cells and fibrin. The glucose diffusion properties of these membranes were studied by a lag time analysis method and compared to those of pure PEO hydrogels. As expected, glucose diffuses through the hydrogel coated membrane and diffusion is not affected by the presence of the EXPTFE membrane. 相似文献
Excimer laser-induced crosslinking of ethylene-propylene-diene elastomer using a trace amount of photoinitiator, 1-hydroxy cyclohexyl phenyl ketone, was evaluated. Gel content measurements on irradiated samples showed that crosslinking was a natural consequence in all, which had undergone exposure to laser radiation. Degree of crosslinking was found to be linear with the laser exposure energy and was found to reach a saturation value of approximately 80% at about 100 J. However, for thicker samples the dependence of gel content i.e. crosslinking was found to be exponential over the range of laser exposure energy in excess of 200 J. As is expected, the tensile strength increased significantly with the increase of crosslinking. The band at 808 cm−1 in the infrared spectra was attributed to the 5-ethylidene-2-norbornene (ENB) content in the polymer. The ENB has a double bond which is considered to be consumed with a high radiochemical yield and thereby contributes to the increase in rate of the formation of intermolecular bridge density. 相似文献
We report a common HPLC method for the single or simultaneous determination of four calcium channel blockers (CCB), namely diltiazem (DTZ), verapamil (VER), nifedipine (NIF) and nitrendipine (NIT) and their active metabolites demetildiltiazem and deacetildiltiazem (MA and M1), norverapamil (NOR), and dehydronifedipine (DHN). DHN was first synthesised in our laboratory and different pH values of the mobil phase were subsequently prepared and tested for chromatographic separation. The detection system and the environmental light conditions were optimised. The best separations of all analytes were obtained using a C18 column and a mobile phase of methanol, 0.04 M ammonium acetate, acetonitrile and triethylamine (2:2:1:0.04 v/v). Quantitation was performed using imipramine (IMI) as the internal standard. For DTZ and its metabolites (M1 and MA), the wavelength chosen was 237 nm; for VER and its metabolite NOR, it was 210 nm; and, finally for NIF and its metabolite DHN and NIT it was 216 nm. When a simultaneous analysis was carried out the wavelength was of 230 nm. The optimum pH were 7.90 and 7.10 when the separation of NIT and DTZ or VER and NIF were carried out, respectively, and 7.90 when a simultaneous separation was carried out. The detection limit of the assay was less than 8 ng ml−1 for all compounds, with coefficients of variation less than 7% (for inter- and intra-day) over the concentration range of 1–1000 ng ml−1. The retention times were less than 11 min. When NIF or NIT were studied, it was necessary to use a sodium vapour lamp in order to avoid the photodegradation which takes place under daylight conditions. 相似文献