首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   160篇
  免费   1篇
  国内免费   4篇
化学   159篇
数学   3篇
物理学   3篇
  2022年   1篇
  2021年   5篇
  2020年   4篇
  2019年   4篇
  2017年   1篇
  2016年   5篇
  2015年   6篇
  2014年   4篇
  2013年   6篇
  2012年   9篇
  2011年   19篇
  2010年   12篇
  2009年   13篇
  2008年   7篇
  2007年   10篇
  2006年   8篇
  2005年   9篇
  2004年   11篇
  2003年   9篇
  2002年   1篇
  2000年   3篇
  1999年   5篇
  1997年   1篇
  1995年   3篇
  1994年   3篇
  1992年   3篇
  1991年   1篇
  1990年   1篇
  1989年   1篇
排序方式: 共有165条查询结果,搜索用时 0 毫秒
71.
Number-average molecular weights of fractions of epoxy resins were estimated by vapor-pressure osmometry and size exclusion chromatography coupled with multiple-angle light scattering. Potential reasons for differences between the two sets of data are examined. The molecular weight dependences of the intrinsic viscosity in tetrahydrofuran and chloroform are discussed in terms of theories which take into account the low-molecular weight character of poly(hydroxy ether) chains. The polymer-solvent interaction parameter is estimated. The impact of the presence of branched chains on the results of size exclusion chromatography is examined. It is shown that the universal calibration of size exclusion chromatographic columns by polystyrene is reliable at molecular weights above 2000 only.  相似文献   
72.
73.
Mass spectrometry (MS) is the most versatile and comprehensive method in “OMICS” sciences (i.e. in proteomics, genomics, metabolomics and lipidomics). The applications of MS and tandem MS (MS/MS or MSn) provide sequence information of the full complement of biological samples in order to understand the importance of the sequences on their precise and specific functions. Nowadays, the control of polymer sequences and their accurate characterization is one of the significant challenges of current polymer science. Therefore, a similar approach can be very beneficial for characterizing and understanding the complex structures of synthetic macromolecules. MS-based strategies allow a relatively precise examination of polymeric structures (e.g. their molar mass distributions, monomer units, side chain substituents, end-group functionalities, and copolymer compositions). Moreover, tandem MS offer accurate structural information from intricate macromolecular structures; however, it produces vast amount of data to interpret. In “OMICS” sciences, the software application to interpret the obtained data has developed satisfyingly (e.g. in proteomics), because it is not possible to handle the amount of data acquired via (tandem) MS studies on the biological samples manually. It can be expected that special software tools will improve the interpretation of (tandem) MS output from the investigations of synthetic polymers as well. Eventually, the MS/MS field will also open up for polymer scientists who are not MS-specialists. In this review, we dissect the overall framework of the MS and MS/MS analysis of synthetic polymers into its key components. We discuss the fundamentals of polymer analyses as well as recent advances in the areas of tandem mass spectrometry, software developments, and the overall future perspectives on the way to polymer sequencing, one of the last Holy Grail in polymer science.  相似文献   
74.
Statistical long-chain branching occurring during the free-radical polymerization of the system sodium 4-vinylbenzenesulfonate (SSNa) and N, N′-methylene-bis(acrylamide) (MBAA) in aqueous medium was studied by ¹H NMR spectroscopy and SEC. The former method yielded the degree of conversion and the content of the three monomer units in the chain, i.e., SSNa, MBAA with pendant vinyl groups, and MBAA as branching points. It was found that the number of individual monomer units per a total of 1000 monomer units does not perceivably change with the degree of conversion and only slightly increases with increasing ratio MBAA/SSNa in the feed.  相似文献   
75.
The secretor status of ABH antigens, determined by FUT2 polymorphisms, affects susceptibility to various infectious diseases. In addition to many SNPs responsible for the nonsecretor phenotype, five nonfunctional alleles (se) resulting from copy number variations have been reported. One of the five alleles generated by an unequal crossover between FUT2 and a pseudogene (SEC1), is sefus. This allele may be misidentified as a functional allele if only common inactivating SNPs are genotyped because it contains the 3ʹ region of the functional FUT2. Therefore, accurate detection of sefus is desirable. For this purpose, a high-resolution melting (HRM) analysis is developed for detection of sefus in which a 284bp fragment of SEC1 and sefus but not FUT2, are amplified. This HRM analysis detected sefus reliably. Thus, an initial screening or prescreening for sefus using HRM analysis seems to be useful for association studies of FUT2.  相似文献   
76.
The concentrations of mercury (Hg), cadmium (Cd) and lead (Pb) at various exposure periods were determined in the gill, kidney, liver and muscle of common carp (Cyprinus carpio L.) co‐exposed to 1.0 µg ml?1 each of Cd2+, Hg2+ and Pb2+ for up to 10 days. Metallothionein fractions (MTs) in these organs were characterized using the hyphenated technique of size‐exclusion chromatography (SEC) and inductively coupled plasma mass spectrometry (ICP‐MS). After 10 days of exposure, maximum toxic metal concentrations of Hg, Cd and Pb were 10.7 (gill), 0.145 (kidney) and 0.112 µg g?1dryweight (gill), respectively. The pattern of accumulation of Hg and Pb was in the order gill > kidney > liver > muscle. In the case of Cd, accumulation was in the order kidney > gill > liver > muscle. Cd and Hg binding MTs were significantly induced in the gill, kidney and liver of all the exposure groups in comparison with the control group (p < 0.05), and the amounts of them increased with the longer exposure time. Despite the higher intracellular Hg concentration and the stronger Hg? SH binding affinity, the amount of Cd‐binding MTs was much higher than that of Hg‐binding MTs. The results indicate that MT synthesis in these organs was clearly metal‐specific. MTs in gill may be used as a bio‐marker to detect the metal pollution caused by Hg and Cd. Zinc and copper binding MTs in the organs of the exposed fish were also increased. This may be due to the MTs' important role in the homeostatic regulation of essential metals and their protective role against the acute toxicity of non‐essential metals. Even though there was considerable accumulation of lead in the organs of the exposed fish, Pb‐binding MT synthesis was non‐significant. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   
77.
An Erratum has been published for this article in Journal of Polymer Science Part A: Polymer Chemistry (2004) 42(10) 2575‐2576 Starlike, highly branched (AxByAz) macromolecules having from a few to 100 arms and molar masses up to 105 were prepared in three stages with the one‐pot, arms‐core‐arms method (By stands for y molcules of former diepoxides introduced into the core). Oligoalcohols, at least partially converted into their alcoholate counterpart states, reacted with diepoxy compounds giving star‐shaped, highly branched macromolecules. With the properly chosen conditions, complete conversion of both starting components was achieved. In this article homostars built with the first and second generation of poly(ethylene oxide) arms (Ax and Az, respectively) are described. The number of arms (f) was determined either by direct measurements of the number‐average molcular weight (Mn) of the first and second stars (Mn of arms Ax and Az is known) or by calculating f from branching indices g and g′ determined from the radius of gyration and the limited viscosity number measured with size exclusion chromatography (SEC) triple detection with TriSEC software. For a few samples, Mn was measured with high‐speed membrane osmometry. The progress of the stars' formation was monitored by 1H NMR, SEC, and matrix‐assisted laser desorption/ionization time‐of‐flight methods. Functionalization of the ? OH end groups in the second generation of arms was observed by 1H and/or 31P NMR. © 2004 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 42: 1576–1598, 2004  相似文献   
78.
The elution behaviour of linear and branched polyethylene samples in SEC was studied. For the branched samples an abnormal late co-elution of large and small macromolecules manifests itself as an abnormal re-increase of the molar mass and the radius of gyration values detected with multi angle light scattering at high elution volumes in SEC. The late co-elution of small and large macromolecules cannot be explained by the SEC mechanism alone. The influence of several experimental parameters on the late co-elution was studied. It was found that the type of SEC column and the flow rate have a significant influence. The late eluting part of the sample was fractionated and separated by HT-SEC- and HT-AF4-MALS. The different results of both methods have been discussed with the aim to find possible explanations for the late elution. The experiments indicate that especially large branched structures show an increased tendency for the phenomenon.  相似文献   
79.
A gradient ranging from methanol to tetrahydrofuran (THF) was applied to a series of poly(methyl methacrylate) (PMMA) standards, using the recently developed concept of SEC-gradients. Contrasting to conventional gradients the samples eluted before the solvent, i.e. within the elution range typical for separations by SEC, however, the high molar mass PMMAs were retarded as compared to experiments on the same column using pure THF as the eluent. The molar mass dependence on retention volume showed a complex behaviour with a nearly molar mass independent elution for high molar masses. This molar mass dependence was explained in terms of solubility and size exclusion effects. The solubility based SEC-gradient was proven to be useful to separate PMMA and poly(n-butyl crylate) (PnBuA) from a poly(t-butyl crylate) (PtBuA) sample. These samples could be separated neither by SEC in THF, due to their very similar hydrodynamic volumes, nor by an SEC-gradient at adsorbing conditions, due to a too low selectivity. The example shows that SEC-gradients can be applied not only in adsorption/desorption mode, but also in precipitation/dissolution mode without risking blocking capillaries or breakthrough peaks. Thus, the new approach is a valuable alternative to conventional gradient chromatography.  相似文献   
80.
程镕时 《高分子科学》2011,29(2):203-213
The response factors of refractive index(RI) and ultraviolet(UV) detectors of size exclusion chromatography (SEC) defined as the ratio of area of output signal to the mass of injected sample are studied and analyzed by using five narrowly distributed polystyrene(PS) standard samples with known molar masses.It is found that the individual response factor for a given sample varies with the concentration of the injected solution within a limited range bounded by an upper and a lower limiting response factor values.This variation reveals the conformational change of the polymer chains with the concentration of the injected solution.The dynamic contact concentrations c_s of the PS samples derived from the response factor data are in good accordance with those reported earlier by other methods.The physical meanings of the signals of the two detectors are further analyzed and theoretically formulated.The solvation of the polymer chain and the conformation changes play an important role in these detecting systems.Both of the solvation number of the structural repeating unit and the extra embedded solvent due to cluster forming in higher concentrations could be deduced from the variation of response factor with the concentration of the injected solution.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号