A rapid, simple and rugged procedure without requiring any prior sample treatment was developed for the determination of acetylsalicylic acid (ASA) in tablets formulations by solid-phase fluorescence spectroscopy. The method was carried out on powdered samples, consisting of an active substance dispersed in lactose, maize starch, talc and magnesium stearate. Previous knowledge of the sample bulk composition is needed for proper application of the method. Wavelengths for maximum excitation and emission were 288 and 318 nm, respectively, and the fluorescence intensity was linear with ASA concentration within the 50-170 mg g−1 range. Detection and quantification limits were 2.2 and 7.3 mg g−1, and the analytical frequency was 200 h−1. For a typical sample, the relative standard deviation of results was estimated as 2.3% (n = 10). Accuracy was assessed by comparing the analytical results obtained with the proposed method with those related to a reference method recommended by British Pharmacopoeia: no differences between the methods were found at the 95% confidence level. 相似文献
Let Ui = (Xi, Yi), i = 1, 2,…, n, be a random sample from a bivariate normal distribution with mean μ = (μx, μy) and covariance matrix . Let Xi, i = n + 1,…, N represent additional independent observations on the X population. Consider the hypothesis testing problem H0 : μ = 0 vs. H1 : μ ≠ 0. We prove that Hotelling's T2 test, which uses (Xi, Yi), i = 1, 2,…, n (and discards Xi, i = n + 1,…, N) is an admissible test. In addition, and from a practical point of view, the proof will enable us to identify the region of the parameter space where the T2-test cannot be beaten. A similar result is also proved for the problem of testing μx ? μy = 0. A Bayes test and other competitors which are similar tests are discussed. 相似文献
Historically, due to the size and nature of the instrumentation, highly skilled laboratory professionals performed clinical
testing in centralized laboratories. Today’s clinicians demand realtime test data at the point of care. This has led to a
new generation of compact, portable instruments permitting ”laboratory” testing to be performed at or near the patient’s bedside
by nonlaboratory workers who are unfamiliar with testing practices. Poorly controlled testing processes leading to poor quality
test results are an insidious problem facing point of care testing today. Manufacturers are addressing this issue through
instrument design. Providers of clinical test results, regardless of location, working with manufacturers and regulators must
create and manage complete test systems that eliminate or minimize sources of error. The National Committee for Clinical Laboratory
Standards (NCCLS) in its EP18 guideline, ”Quality management for unit-use testing,” has developed a quality management system
approach specifically for test devices used for point of care testing (POCT). Simply stated, EP18 utilizes a ”sources of error”
matrix to identify and address potential errors that can impact the test result. The key is the quality systems approach where
all stakeholders – professionals, manufacturers and regulators – collaboratively seek ways to manage errors and ensure quality. We illustrate the use of one quality systems approach, EP18, as a means to advance the quality of test results at point of
care.
Received: 26 June, 2002 Accepted: 17 July 2002
Presented at the European Conference on Quality in the Spotlight in Medical Laboratories, 7–9 October 2001, Antwerp, Belgium
Abbreviations NCCLS National Committee for Clinical Laboratory Standards (formerly) · POCT point of care testing · QC quality control ·
HACCP hazard analysis critical control points · CLIA clinical laboratory improvement amendments (of 1988)
Correspondence to S. S. Ehrmeyer 相似文献
Proficiency testing (PT) is an essential tool used by laboratory accreditation bodies to assess the competency of laboratories.
Because of limited resources of PT providers or for other reasons, the assigned reference value used in the calculation of
z-score values has usually been derived from some sort of consensus value obtained by central tendency estimators such as the
arithmetic mean or robust mean. However, if the assigned reference value deviates significantly from the ‘true value’ of the
analyte in the test material, laboratories’ performance will be evaluated incorrectly. This paper evaluates the use of consensus
values in proficiency testing programmes using the Monte Carlo simulation technique. The results indicated that the deviation
of the assigned value from the true value could be as large as 40%, depending on the parameters of the proficiency testing
programmes under investigation such as sample homogeneity, number of participant laboratories, concentration level, method
precision and laboratory bias. To study how these parameters affect the degree of discrepancy between the consensus value
and the true value, a fractional factorial design was also applied. The findings indicate that the number of participating
laboratories and the distribution of laboratory bias were the prime two factors affecting the deviation of the consensus value
from the true value. 相似文献
This presentation deals with issues of comparability and traceability in food analysis in Australia from several perspectives. This includes the current national (Australian) and increasingly international (Codex) performance-based approach to food analysis. The Australian food regulatory process will be described, particularly those aspects that impact on the analysis of food in a regulatory sense. This section will also describe two areas where specific methods have been mandated in legislation and discuss two case studies where the analytical method has impacted on the elaboration of standards. Other areas to be covered include regulation/requirements relating to supply/availability of reference materials, the use of proficiency testing as a means of ensuring comparability, and, finally, some thoughts on what role BIPM/CCQM may play in the analysis of food.Electronic Supplementary Material Supplementary material is available for this article at
Terry SpencerEmail: Phone: +612-6213-6102Fax: +612-6213-6815
The robustness testing of a normal-phase liquid chromatographic (LC) method for the determination of R-timolol and other related substances in S-timolol maleate was performed applying a two-level Plackett-Burman design. Two qualitative and five quantitative factors were examined. Two types of responses were considered, qualitative, i.e. chromatographic performance criteria, and quantitative ones. The latter were taken into account to determine if the analytical procedure was robust. The quantitative responses were the contents of R-timolol in two S-timolol maleate samples. Even though some significant factor effects were observed on the qualitative responses, the R-timolol contents were not significantly different from those observed at nominal conditions, which demonstrated the robustness of the procedure.Since the experiments of the Plackett-Burman design can be assimilated to laboratories in an interlaboratory study, uncertainty can be evaluated using the robustness test data. The robustness test was set-up in such a way that the required variances could be estimated. It was shown that the robustness set-up allows estimating the reproducibility uncertainty without performing an interlaboratory study. 相似文献
Raman microscopy has been applied to the study of 15th century wall paintings in a chapel of St. Orso Priory palace (Aosta, Italy) in view of their restoration. The use of a transportable instrument has made it possible to work non-destructively in situ without sampling. The main inorganic pigments used by the unknown artist, namely mercury sulphide, azurite, white lead, red and yellow ochre, carbon black and lead tin yellow type I have been identified, and the presence of organic substances and of some decay products (calcium sulphate and oxalate) has been observed. 相似文献
Capillary gc is now rapidly expanding. Naturally, initiation is most often attempted on the basis of the experience acquired with packed columns. However, such an extrapolation is successful only if a number of essential peculiarities of capillary gc are considered. Based on practical examples this paper discusses six essential details: 1) design and maintenance of the gas flow paths, 2) the greatly increased importance of sampling technique, which should not be confined just to stream splitting, 3) the problems in quantitative analysis arising from small sample size, 4) specific sources of trouble related to small amounts of liquid phase, 5) specific arguments for the choice of the carrier gas, clearly pointing to hydrogen as the ideal carrier and, 6) the different way to approach column production. Figures for all selected examples are given. 相似文献
Summary The quantitative use of high speed capillary electrophoresis (HSCE) is examined by applying high voltages across short capillaries.
Acceptable performance in terms of injection precision and migration times were achieved within 1–2 minute analysis times.
HSCE was used for the novel CE application of dissolution test sample solution analysis. The results generated by HSCE compared
well with those generated using validated on-line UV absorbance measurements. It is concluded that HSCE is a viable alternative
and supplement to standard analytical methods employed in dissolution test analysis. 相似文献
Sulfur reduction ability of alumina supported zinc, gallium and zinc-gallium additives for fluid catalytic cracking catalysts
was evaluated in a micro-activity test unit (MAT). Gallium/alumina showed the highest sulfur reduction of 31%, but the cracking
activity of the catalyst was decreased. Zinc-gallium/alumina reduced sulfur in 24 wt.% without decreasing the base catalyst
activity. 相似文献