排序方式: 共有65条查询结果,搜索用时 15 毫秒
61.
Non-contact method for measuring solution concentration using surface plasmon resonance apparatus and heterodyne interferometry 总被引:1,自引:0,他引:1
A simple non-contact method is proposed for measuring the concentration of solutions. Using the significant phase difference between p- and s-polarizations of the reflected light of a surface plasmon resonance apparatus, the variation in the phase difference, which is caused by a variation in the concentration of a test solution, can be accurately measured by common path heterodyne interferometry. Then, by substituting the corresponding variation in the incident angle of light at the base of the SPR prism in a specially derived equation, the concentration of the test solution can be determined. The validity of this method was demonstrated experimentally. This method is characterized by the advantages of the device having a simple non-contact structure; it being easy to operate; and its high accuracy, stability, and resolution. 相似文献
62.
A high-resolution spectroscopy technique is proposed with an optical phase modulator combined with an interleaved optical frequency comb. The optical phase modulator and a frequency-locked laser light guarantee a spectral resolution less than 1 MHz on an absolute frequency axis. A wide measurement frequency range was realized using a 25 GHz optical frequency comb lying over a 4 THz frequency region. An extraction of single tooth intensity from the comb was realized by a heterodyne technique with a frequency-tunable laser used as a local oscillator. Also, the 25 GHz optical frequency comb was interleaved to generate four 100-GHz combs for removing the crosstalk from the 25 GHz neighboring sidebands in the teeth. This proposed spectroscopy technique was experimentally demonstrated with a resonator of less than 1 MHz linewidth and a H13C14N gas cell. Thus, a measurement frequency range higher than 4 THz (1530 nm-1560 nm) was confirmed with an effective spectral resolution 100 kHz order. In addition, the characteristics of the proposed system were compared with those of the previous system with a single-sideband (SSB) optical modulator. 相似文献
63.
Optical heterodyne grating shearing interferometry for long-range positioning applications 总被引:1,自引:0,他引:1
We develop a displacement measurement and positioning system with nanometer resolution over the millimeter traveling range. The method is based on a heterodyne grating shearing interferometry, a homemade lock-in amplifier and a servo control loop for displacement sensing and positioning. The quasi-common optical path configuration of our system provides better immunity against environmental disturbances. The experimental results demonstrate that our system can measure small and long displacement with nanometric resolution. The device achieves a positioning resolution of 2.3 nm over a traveling range of 20 mm. 相似文献
64.
A calibration technique for high-frequency hydrophone utilizing a heterodyne interferometer is presented in this article. The calibration system is mainly composed of optical and signal processing modules. In the displacement measurement, a pellicle is mounted at the surface of water to avoid acousto-optical interaction. The phase modulated carrier signal is digitized and transferred to the computer, then processed by digital phase demodulation. A phase unwrapping algorithm is employed to remove ambiguity of the arctangent function and has proven effective in large displacement measurements. Pellicle displacement and voltage output of the hydrophone in focused ultrasonic field are processed by DFT to determine the amplitudes of the fundamental and harmonic components. Experiments show that the heterodyne technique can provide hydrophone calibration up to 40 MHz, with a slightly smaller sensitivity compared with the National Physical Laboratory (NPL) calibration results for most frequency ranges. Since the heterodyne technique is independent on assumptions about the geometry of the ultrasonic field and the performance of the transducer, it can be easily extended to high frequency and high power ultrasound measurement applications. 相似文献
65.
塞曼激光外差干涉仪的非线性分析及校正 总被引:3,自引:0,他引:3
He-Ne激光器施加纵向磁场或横向磁场构成的纵向塞曼激光器和横向塞曼激光器,是激光外差干涉仪最常用的光源。外差干涉仪原理表明,干涉仪所测位移和仪器测得的光电信号的相位变化,是线性关系。而实际上由于光源和光学系统难于达到理想状态,使二者之间产生了周期性非线性,导致纳米、亚纳米测量难以实现。本文分析了引起非线性的原因及其特性,提出了校正和减小非线性的方法,并证实了其有效性。 相似文献