某型飞机在试飞测试任务过程中,需要对多路机载音视频进行抽引、采集、记录与遥测,用于飞机实时动态监控与事后回放分析。该型飞机的显控数据采用ARINC818(又名航空电子视频总线Avionics Digital Video Bus)专用图像传输协议进行光纤视频传输,对ARINC818总线视频的抽引采集在试飞任务中为首次。由于目前机载采集系统的限制,本文设计了一种基于ARINC818的机载测试系统,满足了该型飞机多通道、高分辨率、多视频格式的信号采集记录。 相似文献
A measure of the sharpness of vessel wall interfaces in carotid artery MRI may be useful for assessing the conspicuity of the wall's features. An edge detection technique was used to measure the signal intensity gradients in 2D time-of-flight (2D-TOF) and double-inversion recovery black-blood (DIR-BB) carotid artery images of normal subjects that were acquired at 1.5 T with 0.55 x 0.55 x 2.0-mm (0.6 mm3) acquisition voxels and zero filled to reduce the in-plane reconstructed voxel size by one half in each dimension as well as with 0.27 x 0.27 x 2.0-mm (0.15 mm3) acquisition voxels and at 3.0 T with 0.27 x 0.27 x 2.0-mm (0.15 mm3) acquisition voxels using surface coils. The gradient intensities of the lumen-to-background interface varied closely with the contrast-to-noise ratio of the 2D-TOF imaging. For the DIR-BB imaging, in which higher spatial frequency artery structures are visible, the gradient intensities at the interfaces were higher than theoretically predicted at both field strengths with smaller acquisition voxels. The use of acquisition voxels smaller than those previously used at 1.5 T can improve the visualization of carotid artery structures at 1.5 and 3.0 T with surface coil reception. 相似文献
This paper proposed a new method for measuring the feedback coefficient in the self-mixing interference. In experiment, the value of feedback coefficient is obtained by measuring the power difference at power jump point that based on the self-mixing vibration sensing system. It realized the measurement of feedback coefficient in range of 1–7.8 and shows a good agreement with the theoretical derivation and the corresponding simulation. Meanwhile, there is a good fitting result with the determination coefficient of 0.98 and line-width broadening factor of 3.245 respectively, which also realized measurement of feedback coefficient and line-width broadening factor at the same time. 相似文献
A membrane system only has a limited operational lifetime, whereby it becomes so severely fouled that continued operation must be stopped. In the cross-flow configuration of membrane filtration of wastewater, both increased cross-flow velocities and decreased operational transmembrane pressures can be used to decrease membrane fouling and extend the life cycle of the membrane separation process. The study found that an optimised usage of two de-clogging techniques, with a 1 h production period followed by a 1 min relaxation period and then a 1 min high cross-flow rate period, resulted in a net productivity increase of 14.8%.
The study involved a detailed investigation into the utilization of two automated cleaning techniques to reduce fouling problems encountered when cross-flow membrane systems are operated with high permeate flux rates. The two cleaning techniques studied were periodic membrane relaxation and a periodic high rate cross-flow. During both the relaxation and high rate cross-flow periods, permeate production was stopped. This results in an operational loss in productivity. When each cleaning technique was operated individually, there was a net productivity decrease of 0.7%, due to the 3.2% operational loss due to cleaning technique being implemented.
The system was developed using a Programmable Logic Controller (PLC) and a Supervisory Control and Data Acquisition (SCADA) system to accurately control and monitor the process. 相似文献