排序方式: 共有81条查询结果,搜索用时 546 毫秒
71.
材料力学性能显微测试系统 总被引:6,自引:1,他引:6
介绍了适用于毫、微米量级材料的力学性能测试系统,该系统包括微型加力装置、显微镜及数字图像处理系统。通过计算机控制,加力机构可以对微小试件按力或位移控制方式加载,载荷大小通过传感器直接由计算机数字化。试件的变形测量采用数字图像相关技术,通过序列图像分析方式,获得试件在不同外力作用下对应的变形,从而获得该材料的应力应变关系。在利用显微镜对微细观图像进行放大时,图像的畸变会影响相关计算的精度,本文采用了精度极高的正交栅板,对成像系统进行标定,有效地消除了高放大倍数下的图像畸变。图像相关技术对被测物体的表面处理非常敏感,本文也对这一问题进行了讨论,并给出两个不同的应用实例。第一个为材料性能试验,对厚度为0.1mm的铝材进行单向拉伸,给出了材料的应力应变关系;第二个为稳态裂纹扩展试验,对用人牙制作的紧凑拉伸试件进行测试,获得裂尖后的COD曲线。实验表明,该测试系统在微细观力学实验中具有广阔的应用前景。 相似文献
72.
Nu Xiao 《Journal of fluorine chemistry》2010,131(3):439-1695
Chromatographic conditions for the separation of fluorinated amino acids and oligopeptides from their non-fluorinated counterparts were explored. The separation of six pairs of analytes, including both aromatic and aliphatic fluorocarbons, was investigated at various temperatures using both hydrocarbon and fluorocarbon columns and eluents. Our results show that when hydrocarbon eluents are used, fluorocarbon column provides better separation of fluorinated amino acids or oligopeptides from their non-fluorinated counterparts; when fluorocarbon eluents are used, hydrocarbon column provides better separation of fluorinated amino acids or oligopeptides from their non-fluorinated counterparts. These chromatographic behaviors reflect the fluorophilicity possessed by fluorinated amino acids and oligopeptides. 相似文献
73.
Yanjie Li Cheng Wen Huimin Xie Anpei Ye Yajun Yin 《Colloids and surfaces. B, Biointerfaces》2009,70(2):169-173
The deformation of human red blood cells subjected to direct stretching by optical tweezers was analyzed. The maximum force exerted by optical tweezers on the cell via a polystyrene microbead 5 μm in diameter was 315 pN. Digital image correlation (DIC) method was introduced to calculate the force and the deformation of the cell for the first time. Force–extension relation curves of the biconcave cell were quantitatively assessed when erythrocytes were stored in Alsever's Solution for 2 days, 5 days, 7 days and 14 days respectively. Experiment results demonstrated that the deformability of red blood cells was impaired with the stored time. 相似文献
74.
Jan Pícha 《Tetrahedron》2009,65(31):6090-6103
In the present work, we describe in detail an efficient solution synthesis of norleucine-derived phosphonopeptides mimicking the peptide sequences Nle-Gly(Ala) and Nle-Gly(Ala)-Val. The most efficient strategy involved use of the benzyl group. The synthesis was achieved through BOP-catalysed coupling of the monobenzyl ester of the N-Cbz-protected phosphonate derivative of norleucine with the hydroxyl moieties of derivatised l-lactic or glycolic acid. Subsequently, complete deprotection of the products was achieved in good yields by one-step Pd-catalysed hydrogenolysis. We also prepared the Fmoc-Nle-Ψ[PO(OH)O]-CH2-COOH synthon and demonstrated that this precursor is a suitable building block for the solid-phase synthesis of cysteine-containing phosphonopeptides. 相似文献
75.
76.
77.
基于MCMC模拟的贝叶斯厚尾金融随机波动模型分析 总被引:1,自引:0,他引:1
针对现有金融时间序列模型建模方法难以刻画模型参数的渐变性问题,利用贝叶斯分析方法构建贝叶斯厚尾SV模型。首先对反映波动性特征的厚尾金融随机波动模型(SV-T)进行贝叶斯分析,构造了基于Gibbs抽样的MCMC数值计算过程进行仿真分析,并利用DIC准则对SV-N模型和SV-T模型进行优劣比较。研究结果表明:在模拟我国股市的波动性方面,SV-T模型比SV-N模型更优,更能反应我国股市的尖峰厚尾的特性,并且证明了我国股市具有很强的波动持续性。 相似文献
78.
Kamel Bouallegue Tamara Allaf Colette Besombes Rached Ben Younes Karim Allaf 《Arabian Journal of Chemistry》2019,12(8):2398-2410
Accelerated Solvent Extraction (ASE) and Dynamic Maceration (DM) were used with n-hexane to study the extraction of oil from date seed powders with different particle sizes. The intensification was studied with instant controlled pressure drop (DIC) as texturing pretreatment. DM yields increased from 4.57% to 10.49 ± 0.05% dry–dry basis (ddb) when particle size decreased from 1.4 to 0.2 mm. For coarsely grounded seed powder, ASE oil yields were 11.35 ± 0.05% ddb and 14.15% ddb for untreated and DIC date-seeds, respectively. Optimized DIC pretreatment allowed the smallest particle size powder to get 15.2 ± 0.05% ddb as ASE yields, while the 2-h DM yields increased from 4.67 to 11.62 ± 0.05% ddb for particle size decreased from 1.4 to 0.2 mm, respectively. Fundamental analysis of various powders was achieved through washing–diffusion phenomenological model. DIC texturing implied higher washing stage, with relative starting accessibility %δYs of 70% against 55% for untreated particles. Consequently, the diffusion stage time was dramatically reduced, without great modification of effective diffusivity Deff value. Therefore, DIC ground seeds greatly enhanced the mass transfer mechanism. The evaluation of starting accessibility δYs enables to establish an empirical relationship between δYs and particle diameter δYs = f(D). Finally, DIC texturing did not imply any modification of the lipid profile. 相似文献
79.
A. Benallal T. Berstad T. Børvik O.S. Hopperstad I. Koutiri R. Nogueira de Codes 《International Journal of Plasticity》2008
An experimental investigation of the Portevin–Le Chatelier (PLC) effect in the aluminium alloy AA5083-H116 is undertaken in this study through five different tests involving round, prismatic and flat notched specimen geometries. Measurements based on strain gages and digital image correlation (DIC) are used to capture and characterize the spatio-temporal features of the PLC behaviour. Inhomogeneous deformation with various localization bands caused by the PLC effect is observed in all tests, and the band characteristics are measured. The McCormick elastic–viscoplastic constitutive relation, developed for metals exhibiting this type of dynamic strain aging, is then described in detail, before the various parameters required by the model are determined based on available material tests. The model is finally used in full-scale 3D numerical simulations of the physical tests using the explicit solver of the non-linear finite element code LS-DYNA. It will be shown that the numerical results are able to reproduce most of the experimentally observed phenomena with reasonable accuracy. However, if the model is used to study the micromechanical mechanisms controlling the macromechanical behaviour of materials exhibiting PLC effects (such as the band morphology), more advanced constitutive relations may be required. 相似文献
80.
《Comptes Rendus Mecanique》2017,345(6):363-369
A uniaxial experiment is performed on an ultra-thin specimen made of 17-7 precipitation hardened stainless steel. An anti-wrinkling setup allows for the characterization of the mechanical behavior with Integrated Digital Image Correlation (IDIC). The result shows that a single uniaxial experiment investigated via IDIC possesses enough data (and even more) to characterize a complete anisotropic elastoplastic model. 相似文献