首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   397篇
  免费   78篇
  国内免费   16篇
化学   423篇
晶体学   1篇
力学   25篇
数学   3篇
物理学   39篇
  2023年   16篇
  2022年   29篇
  2021年   30篇
  2020年   46篇
  2019年   30篇
  2018年   17篇
  2017年   26篇
  2016年   35篇
  2015年   34篇
  2014年   34篇
  2013年   37篇
  2012年   31篇
  2011年   21篇
  2010年   17篇
  2009年   25篇
  2008年   14篇
  2007年   14篇
  2006年   14篇
  2005年   8篇
  2004年   6篇
  2003年   5篇
  1999年   1篇
  1983年   1篇
排序方式: 共有491条查询结果,搜索用时 15 毫秒
61.
This study describes the development of an analytical methodology based on the use of microchip electrophoresis (ME) devices integrated with capacitively coupled contactless conductivity detection (C4D) for the separation and detection of inorganic anions in post‐blast explosive residues. The best separation condition was achieved using a running buffer composed of 35 mmol/L lactic acid, 10 mmol/L histidine and 0.070 mmol/L cetyl(trimethyl ammonium) bromide. For C4D measurements, the highest sensitivity was obtained applying a 700 kHz sinusoidal wave with excitation voltage of 20 Vpp. The separation of Cl?, NO3?, NO2?, SO42?, ClO4? and ClO3? was performed within ca. 150 s with baseline resolution and efficiencies between 4.4 × 104 and 1.7 × 105 plates/m. The found limits of detection ranged between 2.5 and 9.5 μmol/L. Last, real samples of post‐blast explosive residues were analyzed on the ME‐C4D devices obtaining successfully the determination of Cl?, NO3? and SO42?. The achieved concentration values varied between 12.8–72.5 mg/L for Cl?, 1.7–293.1 mg/L for NO3? and 1.3–201.3 mg/L for SO42?. The data obtained using ME‐C4D devices were in good agreement with the concentrations found by ion chromatography. The approach reported herein has provided short analysis time, instrumental simplicity, good analytical performance and low cost. Furthermore, the ME‐C4D devices emerge as a powerful and portable analytical platform for on‐site analysis demonstrating to be a promising tool for the crime scene investigation.  相似文献   
62.
A significant growth of research on adaptive liquid lens is achieved over the past decades, and the field is still attracting increasing attentions, focusing on the transition from the current stage to the commercialized stage. The challenges faced are not limited to fabrication, material, small tuning range in focal lengths, additional control systems, limitations in special actuation methods and so on. In addition, the use of external driving parts or systems induce extra problem on bulky appearance, high cost, low reliability etc. Therefore, adaptive liquid lens will be an interesting research focus in both microfluidics and optofluidics science. This review attempts to summarize and focus on the droplet profile deformation under different driving mechanisms in tunable liquid microlens as well as the application in cameras, cell phone and so on. The driving techniques are generally categorized in terms of mechanisms and driving sources.  相似文献   
63.
Magnetic digital microfluidics uses magnetic force to manipulate droplets on a Teflon‐coated substrate through the added magnetic particles. To achieve a wide range of droplet manipulation, hydrophilic patterns, known as surface energy traps, are introduced onto the Teflon‐coated hydrophobic substrate. However, the Teflon‐coated substrate is difficult to modify because it is nonwettable, and existing techniques for patterning surface energy traps have many limitations. Inspired by the mussel adhesion mechanism, we use polydopamine, a bioinspired substance that adheres strongly to almost any materials, to pattern surface energy traps on the Teflon‐coated substrate with a great ease. We have optimized the polydopamine coating protocol and characterized the surface properties of the polydopamine surface energy traps. Droplet operations including particle extraction, liquid dispensing, liquid shaping, and cross‐platform transfer have been demonstrated on the polydopamine surface energy trap‐enabled magnetic digital microfluidic platform in both single‐plate and two‐plate configurations. Furthermore, the detection of hepatitis B surface antigen using ELISA has been demonstrated on the new magnetic dgitial microfluidic platform. This new bioinspired magnetic digital microfluidic platform is easy to fabricate and operate, showing a great potential for point‐of‐care applications.  相似文献   
64.
A flexible skin‐mounted microfluidic potentiometric device for simultaneous electrochemical monitoring of sodium and potassium in sweat is presented. The wearable device allows efficient natural sweat pumping to the potentiometric detection chamber, containing solid‐contact ion‐selective Na+ and K+ electrodes, during exercise activity. The fabricated microchip electrolyte‐sensing device displays good analytical performance and addresses sweat mixing and carry‐over issues of early epidermal potentiometric sensors. Such soft skin‐worn microchip platform integrates potentiometric measurement, microfluidic technologies with flexible electronics for real‐time wireless data transmission to mobile devices. The new fully integrated microfluidic electrolyte‐detection device paves the way for practical fitness and health monitoring applications.  相似文献   
65.
66.
We report the use of a PTFE‐based microfluidic device for the encapsulation of living, therapeutically‐active cells within monodisperse alginate microspheres. We present a novel microfluidic platform and a flexible experimental method for the production of alginate microspheres. Cell lines HEK293, U‐2 OS and PC12 were separately encapsulated using this method, with minimal loss of cell viability.

  相似文献   

67.
The formation of a line of equally spaced particles at the centerline of a microchannel, referred as “particle ordering,” is desired in several microfluidic applications. Recent experiments and simulations highlighted the capability of viscoelastic fluids to form a row of particles characterized by a preferential spacing. When dealing with non-Newtonian fluids in microfluidics, the adherence condition of the liquid at the channel wall may be violated and the liquid can slip over the surface, possibly affecting the ordering efficiency. In this work, we investigate the effect of wall slip on the ordering of particles suspended in a viscoelastic liquid by numerical simulations. The dynamics of a triplet of particles in an infinite cylindrical channel is first addressed by solving the fluid and particle governing equations. The relative velocities computed for the three-particle system are used to predict the dynamics of a train of particles flowing in a long microchannel. The distributions of the interparticle spacing evaluated at different slip coefficients, linear particle concentrations, and distances from the channel inlet show that wall slip slows down the self-assembly mechanism. For strong slipping surfaces, no significant change of the initial microstructure is observed at low particle concentrations, whereas strings of particles in contact form at higher concentrations. The detrimental effect of wall slip on viscoelastic ordering suggests care when designing microdevices, especially in case of hydrophobic surfaces that may enhance the slipping phenomenon.  相似文献   
68.
Heat energy can transfer via convection, conduction, and radiation. Based on convection and conduction in microfluidics, people have designed and fabricated many novel devices. However, almost none of them has adaptivity, thus restricting practical applications under different conditions. To solve this problem, here we propose a passive approach to adaptive responses. That is,we consider the thermal convection-conduction process in microfluidic structures where Darcy’s law and Fourier’s law are both valid. By carefully designing two key parameters(i.e., tensorial thermal conductivity and tensorial permeability) of a metashell,we theoretically reveal that its effective properties(i.e., effective thermal conductivity and effective permeability) can adaptively change according to the inside object, thus yielding the "chameleonlike metashell". Further, this metashell is passive since it requires no prior knowledge of the inside object. We also report that the chameleonlike behavior can occur for anisotropic inside objects, nonuniform external fields, or even complex shapes. All theoretical analyses agree well with finite-element simulations.The chameleonlike metashell can act as an intelligent metamaterial in microfluidics for its adaptive responses, and it can also benefit other physical fields where convection plays a role, such as mass diffusion.  相似文献   
69.
Nucleic acid amplification tests (NAATs)integrated on a chip hold great promise for point-of-care diagnostics. Currently, nucleic acid (NA) purification remains time-consuming and labor-intensive, and it takes extensive efforts to optimize the amplification chemistry. Using selective electrokinetic concentration, we report one-step, liquid-phase NA purification that is simpler and faster than conventional solid-phase extraction. By further re-concentrating NAs and performing polymerase chain reaction (PCR) in a microfluidic chamber, our platform suppresses non-specific amplification caused by non-optimal PCR designs. We achieved the detection of 5 copies of M. tuberculosis genomic DNA (equaling 0.3 cell) in real biofluids using both optimized and non-optimal PCR designs, which is 10- and 1000-fold fewer than those of the standard bench-top method, respectively. By simplifying the workflow and shortening the development cycle of NAATs, our platform may find use in point-of-care diagnosis.  相似文献   
70.
Ambient ionization based on liquid extraction is widely used in mass spectrometry imaging (MSI) of molecules in biological samples. The development of nanospray desorption electrospray ionization (nano-DESI) has enabled the robust imaging of tissue sections with high spatial resolution. However, the fabrication of the nano-DESI probe is challenging, which limits its dissemination to the broader scientific community. Herein, we describe the design and performance of an integrated microfluidic probe (iMFP) for nano-DESI MSI. The glass iMFP, fabricated using photolithography, wet etching, and polishing, shows comparable performance to the capillary-based nano-DESI MSI in terms of stability and sensitivity; a spatial resolution of better than 25 μm was obtained in these first proof-of-principle experiments. The iMFP is easy to operate and align in front of a mass spectrometer, which will facilitate broader use of liquid-extraction-based MSI in biological research, drug discovery, and clinical studies.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号