排序方式: 共有126条查询结果,搜索用时 12 毫秒
91.
The paper described a new ionic liquid, 1,3-dibutylimidazolium hexafluorophosphate, as extraction solvent for extraction and preconcentration of organophosphorus pesticides (fenitrothion, parathion, fenthion and phoxim) from water and fruit samples by dispersive liquid–liquid microextraction combined with high-performance liquid chromatography. The effects of experimental parameters, such as extraction solvent volume, disperser solvent and its volume, extraction and centrifugal time, sample pH, extraction temperature and salt addition, on the extraction efficiency were investigated. An extraction recovery of over 75% and enrichment factor of over 300-fold were obtained under the optimum conditions. The linearity relationship was also observed in the range of 5–1000 μg L−1 with the correlation coefficients (r2) ranging from 0.9988 to 0.9999. Limits of detection were 0.01–0.05 μg L−1 for four analytes. The relative standard deviations at spiking three different concentration levels of 20, 100 and 500 μg L−1 varied from 1.3–2.7, 1.4–1.9 and 1.1–1.7% (n = 7), respectively. Three real samples including tap water, Yellow River water and pear spiked at three concentration levels were analyzed and yielded recoveries ranging from 92.7–109.1, 95.0–108.2 and 91.2–108.1%, respectively. 相似文献
92.
Qingxiang Zhou Xiaoguo Zhang Guohong Xie Junping Xiao 《Journal of separation science》2009,32(22):3945-3950
This article describes a new, rapid and sensitive method for the determination of chlorotoluron, diethofencarb and chlorbenzuron from water samples with temperature‐controlled ionic liquid‐dispersive liquid‐phase microextraction. In the preconcentration procedure, ionic liquid 1‐hexyl‐3‐methylimidazolium hexafluorophosphate [C6MIM] [PF6] was employed as the extraction solvent. The parameters, such as volume of [C6MIM] [PF6], sample pH, extraction time, centrifuging time, temperature and salting‐out effect, were investigated in detail. Under the optimal extraction conditions, it has been found that three analytes had excellent LODs (S/N=3) in the range of 0.04–0.43 μg/L. The RSDs (n=6) were in the range of 1.3–4.7%. The proposed method was evaluated with lake water, tap water and melted snow water samples. The experimental results indicated that the proposed method had excellent prospect and would be widely used in the future. 相似文献
93.
离子色谱法同时测定离子液体中六氟磷酸根及痕量杂阴离子 总被引:4,自引:0,他引:4
建立了一种同时测定离子液体中六氟磷酸根(PF~6)和痕量杂阴离子氟、氯、溴(F~,Cl~,Br~)的离子色谱方法(IC)。样品经溶解、稀释、过滤后用Dionex IonPac AS22分离柱(250 mm×4 mm)分离,淋洗液为碳酸盐-乙腈体系(体积比为70:30),流速1.0 mL/min,采用Dionex DS6电导检测器检测,外标法定量。F~,Cl~,Br~和PF~6的线性范围分别为0.5~50 μg/L、10~200 μg/L、10~200 μg/L和0.9~45 mg/L,线性相关系数分别为0.9999,0.9998,0.9999和0.9998,加标回收率为94.5%~100.5%,相对标准偏差为0.63%~1.03%,检出限(以信噪比为3计)分别为0.5 μg/L、2.0 μg/L、5.0 μg/L和0.9 mg/L。该方法用于离子液体中六氟磷酸根和痕量杂阴离子的同时测定,结果令人满意。 相似文献
94.
Estefanía M. Martinis Roberto A. Olsina Jorgelina C. Altamirano Rodolfo G. Wuilloud 《Talanta》2009,78(3):857-524
A novel on-line preconcentration method based on liquid-liquid (L-L) extraction with room temperature ionic liquids (RTILs) coupled to flame atomic absorption spectrometry (FAAS) was developed for cadmium determination in plastic food packaging materials. The methodology is based on the complexation of Cd with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) reagent after sample digestion followed by extraction of the complex with the RTIL 1-butyl-3-methylimidazolium hexafluorophosphate ([C4mim][PF6]). The mixture was loaded into a flow injection analysis (FIA) manifold and the RTIL rich-phase was retained in a microcolumn filled with silica gel. The RTIL rich-phase was then eluted directly into FAAS. A enhancement factor of 35 was achieved with 20 mL of sample. The limit of detection (LOD), obtained as IUPAC recommendation, was 6 ng g−1 and the relative standard deviation (R.S.D.) for 10 replicates at 10 μg L−1 Cd concentration level was 3.9%, calculated at the peak heights. The calibration graph was linear and a correlation coefficient of 0.9998 was achieved. The accuracy of the method was evaluated by both a recovery study and comparison of results with direct determination by electrothermal atomic absorption spectrometry (ETAAS). The method was successfully applied for Cd determination in plastic food packaging materials and Cd concentrations found were in the range of 0.04-10.4 μg g−1. 相似文献
95.
研究了双酚A(BPA)在十二烷基硫酸钠(SDS)现场自组装膜与离子液体N-丁基吡啶夫氟磷酸盐([ bupy]PF6)复合修饰碳糊电极(SDS-[ bupy]PF6/CPE)上的电催化氧化行为和电化学动力学性质.实验结果表明,在SDS-[ bupy]PF6/CPE上BPA发生了一受扩散控制的不可逆电化学氧化过程,用循环伏安(CV)法和计时电流(CA)法测得BPA在SDS-[bupy]PF6/CPE上的电极反应过程动力学参数.用方波伏安(SWV)法测得BPA氧化峰电流(Ipa)与其浓度在1.0×10-5~ 1.0×10-3 mol/L范围内呈良好的线性关系,线性方程为Ipa(μA) =2.635 +51.30c( 10-3 mol/L),r =0.998 1,检测限(S/N=3)为3.01×10-7 mol/L,同时运用SWV法对湖水样品中双酚A的含量进行了电化学定量测定. 相似文献
96.
Synthesis of bis-ornithine, a new Cα,α-disubstituted α-amino acid bearing orthogonally protected α and δ amine groups is reported. Bis-ornithine (bisOrn) and dipeptides containing bis-ornithine have been synthesized in solution up to multigram scale. As a first example, one of these compounds Boc-βAla-bisOrn(Alloc)2-OH has been attached to a solid support and used as template for the synthesis of a symmetrical assemblage of peptides. 相似文献
97.
基于与卡尔-菲休试剂的反应用库仑滴定法测定了六氟磷酸锂中的微量水分.对同一试样的不同进样量(0.5~5.0 mL 共 10 份)按所提出方法对其水分进行了测定,所得结果在26.3~27.9 μg·g-1 之间,平均值为 27.4μg·g-1,相对标准偏差为 0.72%. 相似文献
98.
Cu2+ complexes with peptides containing three histidine residues have very specific metal binding abilities and can mimic the structures of various multi-histidine metal binding sites in proteins. The main goal of the work concerns the investigations of coordination abilities of the group of N-terminally protected Ac-His-Arg-His-Gly-His-Gly, Ac-His-Gly-His-Arg-His-Gly, Ac-Gly-His-His-Arg-His-Gly and Ac-His-His-Gly-His-Arg-Gly, and their unprotected analogs His-Arg-His-Gly-His-Gly, His-Gly-His-Arg-His-Gly, Gly-His-His-Arg-His-Gly and His-His-Gly-His-Arg-Gly towards Cu2+ ions. Detailed spectroscopic (UV/Vis, CD and EPR) and potentiometric studies have been made. The stoichiometry and binding mode for each ligand–Cu2+ system were determined. 相似文献
99.
Estefanía M. Martinis Roberto A. Olsina Jorgelina C. Altamirano Rodolfo G. Wuilloud 《Analytica chimica acta》2008,628(1):41-48
A sensitive preconcentration methodology for Cd determination at trace levels in water samples was developed in this work. 1-Butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) room temperature ionic liquid (RTIL) was successfully used for Cd preconcentration, as cadmium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol complex [Cd-5-Br-PADAP]. Subsequently, Cd was back-extracted from the RTIL phase with 500 μL of 0.5 mol L−1 nitric acid and determined by electrothermal atomic absorption spectrometry (ETAAS). A preconcentration factor of 40 was achieved with 20 mL of sample. The limit of detection (LOD) obtained under optimum conditions was 3 ng L−1 and the relative standard deviation (R.S.D.) for 10 replicates at 1 μg L−1 Cd2+ concentration level was 3.5%, calculated at peak heights. The calibration graph was linear from concentration levels near the detection limits up to at least 5 μg L−1. A correlation coefficient of 0.9997 was achieved. Validation of the methodology was performed by standard addition method and analysis of certified reference material (CRM). The method was successfully applied to the determination of Cd in river and tap water samples. 相似文献
100.
Present study described a simple, sensitive, and viable method for the determination of bisphenol A, 4-n-nonylphenol and 4-tert-octylphenol in water samples using temperature-controlled ionic liquid dispersive liquid-phase microextraction coupled to high performance liquid chromatography-fluorescence detector. In this experiment, 1-octyl-3-methylimidazolium hexafluorophosphate ([C8MIM][PF6]) was used as the extraction solvent, and bisphenol A, 4-n-nonylphenol and 4-tert-octylphenol were selected as the model analytes. Parameters affecting the extraction efficiency such as the volume of [C8MIM][PF6], dissolving temperature, extraction time, sample pH, centrifuging time and salting-out effect have been investigated in detail. Under the optimized conditions, good linear relationship was found in the concentration range of 1.0-100 μg L−1 for BPA, 1.5-150 μg L−1 for 4-NP, and 3-300 μg L−1 for 4-OP, respectively. Limits of detection (LOD, S/N = 3) were in the range of 0.23-0.48 μg L−1. Intra day and inter day precisions (RSDs, n = 6) were in the range of 4.6-5.5% and 8.5-13.3%, respectively. This method has been also successfully applied to analyze the real water samples at two different spiked concentrations and excellent results were obtained. 相似文献