Capillary GC coupled to an atomic emission detector (AED) provides a powerful new hyphenated technique for the separation and characterization of complex mixtures and compounds. The AED provides simultaneous and truly specific multi-element detection. The specificity of detection reduces the need for the complex sample pretreatment procedures which are necessary to reduce the interference from co-eluted substances which is experienced with detectors such as the FID and the ECD. A range of environmentally significant problems has been studied, including PCB analysis, the characterization of the reaction products of a novel waste treatment process, and the profiling of sulfur-containing species formed by the pyrolysis of various types of coal. 相似文献
Arrhenius parameters values, in non-isothermal kinetic vaporisation processes for a series of compounds with related structures,
have been calculated. This was made using a method of calculation that allows to find the most probable vaporisation mechanisms.
According to this method DTG curves were compared with some theoretical ones reported in literature, whose shape results to
be only a function of the mechanisms. In this way the choice of the mathematical functions which can be inserted in the kinetic
equations, was influenced by the shape of the DTG plots and other thermal analysis signals thus allowing to choose the most
probable mechanisms.
The kinetic parameters derived from these mechanisms were compared, using statistical analysis, with those obtained from another
method of calculation based on ‘a priori’ vaporisation mechanism chosen for the investigated liquid–gas transition.
The standard deviations of the slope and of the intercept, together with the standard deviation and the square correlation
coefficient (r2) of the linear regression equations related to the mechanisms of the two methods were calculated. Student t-test, Fisher F-test, confidence intervals (c.i.) and residuals valueswere also given.
Statistical analysis shows that the mechanisms obtained with the former method (diffusive and geometrical models) and the
related Arrhenius parameters result to be more significant (in terms of probability) than the corresponding quantities of
the latter for which a first-order model was chosen.
This revised version was published online in August 2006 with corrections to the Cover Date. 相似文献
The fast trace analysis method used to monitor 2,3,7,8-TCDD in stack gas during the incineration of the waste from Seveso is described. The sampling of volatile organic compounds from flue gases, distributed between all three aggregation states, is based on a micromethod developed for the trace analysis of water using a specially dimensioned adsorptive charcoal filter (1.5 mg charcoal). In conjunction with subsequent GC/MS measurements the rapid “fast cycle trace analysis” ensured specific 2,3,7,8-TCDD detection down to 100 pg per m3 flue gas in cycle times of about 1–2 hours. 相似文献
In this work, different extracts from the microalga Spirulina platensis are obtained using pressurized liquid extraction (PLE) and four different solvents (hexane, light petroleum, ethanol and water). Different extraction temperatures (115 and 170 degrees C) were tested using extraction times ranging from 9 to 15 min. The antioxidant activity of the different extracts is determined by means of an in vitro assay using a free radical method. Moreover, a new and fast method is developed using micellar electrokinetic chromatography with diode array detection (MEKC-DAD) to provide a preliminary analysis on the composition of the extracts. This combined application (i.e., in vitro assays plus MEKC-DAD) allowed the fast characterization of the extracts based on their antioxidant activity and the UV-vis spectra of the different compounds found in the extracts. To our knowledge, this work shows for the first time the great possibilities of the combined use of PLE-in vitro assay-MEKC-DAD to investigate natural sources of antioxidants. 相似文献
New procedures were developed for the synthesis of 3,3-bis(hydroxymethyl)oxetane dinitrate (1) by O-nitration of the corresponding glycol (3) or its mononitrate (6), which were prepared by the reactions of 2,2-bis(hydroxymethyl)propane-1,3-diol (pentaerythritol) (2) mono- (4) and dinitrates (5), respectively, with alkali. A new method was devised for the synthesis of compounds 4 and 5 by the reaction of tetraol 2 with concentrated HNO3 in dichloroethane. The structures of compounds 1 and 6 were established by X-ray diffraction analysis. 相似文献
The thermal reactions of Ru3(CO)12 with RCOCH=CHPh (R=Me, p-MeC6H4) in hydrocarbon solvents lead to the formation of a series of complexes, several of which have been isolated as individual compounds by chromatography. The dinuclear complex Ru2(-H)(CO)6(-MeCOCH=CPh) and the tetranuclear complex Ru4(-H)(-CO)(CO)7(p-MeC6H4 COCH=CPh)(-p-MeC6H4COCH=CPh)(4-p-MeC6H3COCH=CHPh) are characterized by an X-ray structural study. The structures of other reaction products are discussed on the basis of spectral data. The reactions are accompanied by reduction of the starting enones to the corresponding unsaturated ketones.Translated fromIzvestiya Akademii Nauk. Seriya Khimicheskaya, No. 7, pp. 1285–1293, July, 1993. 相似文献
Spatial structure of six β-substituted enones, with common structure R1O–CR2CH–COCF3, were R1 = C2H5, R2 = H (ETBO); R1 = R2 = CH3 (TMPO); R1 = C2H5, R2 = C6H5 (ETPO); R1 = C2H5, R2 = 4- O2NC6H4 (ETNO); R1 = C2H5, R2 = C(CH3)3 (ETDO) were investigated by 1H and 19F NMR, infrared spectroscopy and AM1 calculations. NMR spectra revealed that enones (MBO), (ETBO) and (TMPO) are exclusively (3E) isomers, whereas in (ETPO), (ETNO) and especially in (ETDO) the percentage of (3Z) isomers is significant and depends on the nature of solvents. Conformational behaviour of studied enones are determined by the rotation around of CC double bond, C–C and C–O single bonds (correspondingly trifluoroacetyl and alkoxy groups), and (EZZ) conformer being the most stable in all cases. IR spectra revealed that with the exception of (ETDO) (EZZ) conformer is most populated in all cases. Bulky substituents like phenyl or tert-butyl group at β-position of enone result in the equilibrium mainly between (EZZ) and (ZZZ) forms, whereas β-hydrogen and β-methyl substituents determine the equilibrium between (EZZ) and (EEZ) or (EZE) conformers. 相似文献
Raman spectra of propylamine (C3H7NH2) and its binary mixtures, C3H7NH2 + CH3OH with varying mole fractions of the reference system, C3H7NH2, C were recorded in two widely apart wavenumber regions, 3100-3600 cm(-1) and 1225-1325 cm(-1). In the former region, the two Raman bands at approximately 3305 and approximately 3326 cm(-1), obtained after the line shape analysis, which were assigned to symmetric nu(N-H) and anti-symmetric nu(N-H) stretching modes, respectively, show a downshift upon dilution. However, whereas the nu(N-H) anti-symmetric mode shows a shift of 18.6 cm(-1), the nu(N-H) symmetric mode shows a much smaller shift (5.7 cm(-1)) between neat liquid and high dilution, C = 0.1. This aspect has been explained using the optimized geometries calculated employing ab initio theory (MP2 level) for the neat C3H7NH2 and its different hydrogen-bonded complexes. The linewidth versus concentration plot for the nu(N-H) anti-symmetric stretching mode, however exhibits a distinct maxima at C = 0.4, which has been explained as a slight departure from the concentration fluctuation model. In the latter region, a symmetric peak is observed, which corresponds to nu(C-N) stretching mode, which shows an upshift upon dilution and an almost linear concentration dependence. This has also been explained in terms of the parameters obtained from the optimized geometries of the different hydrogen-bonded complexes. 相似文献
A procedure for elemental composition determination of water-borne river particles (Po River) on both size-fractionated and unfractionated submicron particles (0.1–1 μm) by graphite furnace atomic absorption spectroscopy (GFAAS) and inductively coupled plasma-mass spectrometry (ICP-MS) is reported. Sample fractionation was performed using sedimentation field-flow fractionation (SdFFF). The distribution of relative mass vs. particle size was determined using UV detection. Fractions were collected over a narrow size range for scanning electron microscopy. With this combination of techniques the mass, elemental composition, and shape distributions can be obtained across the size spectrum of the sample.
The size distributions of the major elements (Al, Fe) were determined by coupling both GFAAS and ICP-MS techniques to the SdFFF. The procedure was validated using a reference clay sample. Satisfactory agreement was found between both the GFAAS and ICP-MS aluminium signal and the UV detector signal. Some discrepancies were observed in the Fe/Al ratios when comparing GFAAS and ICP-MS. Thus further investigation is in order to fully assess the role of SdFFF-ICP-MS and SdFFF-GFAAS techniques for elemental characterisation of aquatic colloids. Both GFAAS and ICP-MS signals unambiguously indicate a significantly higher Fe content in the lower size range, which is consistent with previous investigations.
Trace element levels in unfractionated Po River particles, determined by both GFAAS and ICP-MS, show good agreement. The high levels of Cu, Pb, Cr and Cd found associated with the colloidal particles underlines the significance of the environmental role played by the suspended matter in rivers in both highly industrialised and intensively cultivated areas. 相似文献
The solid phase extraction as a solvent-free method for the analysis of oil and grease in waters was studied. The use of
a PTFE surface as a solid phase allows the retention of the volatile fraction of oil and grease, and further analysis of carbon–hydrogen
bonds using infrared spectroscopy can be done on the surface.
Various oils and grease samples were tested: n-hexadecane, n-tetradecane, n-nonadecane, n-docosane, isooctane, diesel oil
and gasoline. Temperatures from 25° to 90 °C and a range of heating times were checked for extraction.
Precision tests showed relative standard deviation values of around 10% in several samples of the same concentration. Calibration
lines of n-hexadecane showed high correlation coefficients from 0.9 to 30 mg/l. Recoveries for the various oils using different
calibration lines showed values from 90 to 110%.
The method described here is fast and clean, and allows reproducible measurements of oil and grease in water that do not require
the use of a solvent.
Received March 1, 2001; accepted August 15, 2001; published online July 15, 2002 相似文献