首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   175篇
  免费   5篇
  国内免费   2篇
化学   182篇
  2022年   3篇
  2021年   4篇
  2020年   7篇
  2019年   3篇
  2018年   4篇
  2017年   11篇
  2016年   5篇
  2015年   12篇
  2014年   7篇
  2013年   12篇
  2012年   19篇
  2011年   33篇
  2010年   24篇
  2009年   17篇
  2008年   12篇
  2007年   4篇
  2006年   1篇
  2005年   3篇
  2004年   1篇
排序方式: 共有182条查询结果,搜索用时 17 毫秒
21.
A hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC LC-MS/MS) method using multiple scan modes was developed to separate and quantify 11 compounds and lipid classes including acetylcholine (AcCho), betaine (Bet), choline (Cho), glycerophosphocholine (GPC), lysophosphatidylcholine (LPC), lysophosphatidylethanolamine (LPE), phosphatidylcholine (PC), phosphatidylethanolamine (PE), phosphatidylinositol (PI), phosphocholine (PCho) and sphingomyelin (SM). This includes all of the major choline-containing compounds found in foods. The method offers advantages over other LC methods since HILIC chromatography is readily compatible with electrospray ionization and results in higher sensitivity and improved peak shapes. The LC-MS/MS method allows quantification of all choline-containing compounds in a single run. Tests of method suitability indicated linear ranges of approximately 0.25-25 μg/ml for PI and PE, 0.5-50 μg/ml for PC, 0.05-5 μg/ml for SM and LPC, 0.5-25 μg/ml for LPE, 0.02-5 μg/ml for Cho, and 0.08-8 μg/ml for Bet, respectively. Accuracies of 83-105% with precisions of 1.6-13.2% RSD were achieved for standards over a wide range of concentrations, demonstrating that this method will be suitable for food analysis. 8 polar lipid classes were found in a lipid extract of egg yolk and different species of the same class were differentiated based on their molecular weights and fragment ion information. PC and PE were found to be the most abundant lipid classes consisting of 71% and 18% of the total phospholipids in egg yolk.  相似文献   
22.
More and more polar stationary phases have become available for the separation of small polar compounds in the past decade as hydrophilic interaction chromatography (HILIC) continues to find applications in new fields (e.g., metabolomics and proteomics). Bare silica phases remain popular, especially in the bio-analytical area. A wide range of functional groups (e.g., amino, amide, diol, sulfobetaine, and triazole) have been employed as polar stationary phases for HILIC separation. This review provides a survey of the popular stationary phases commercially available and discusses the retention and selectivity characteristics of the polar stationary phases in HILIC. The purpose of the review is not to provide a comprehensive overview of literature reports, but rather focuses on findings that demonstrate retention and selectivity of the polar stationary phases in HILIC.  相似文献   
23.
A hydrophilic interaction liquid chromatographic method with tandem mass spectrometry for the determination of atenolol, a beta-blocking agent, in human plasma has been developed and validated over the curve range of 10--2000 ng/mL. The assay was based on protein precipitation followed by evaporation of the extraction solvent, reconstitution with acetonitrile, and chromatography on an Hypersil silica column (50 x 4.6 mm) using a low aqueous--high organic mobile phase. The mobile phase consists of 85% acetonitrile, 15% water, 0.5% acetic acid and 0.04% trifluoroacetic acid and runs isocratically at a flow rate of 2.0 mL/min. The column ef fluent was split so that 50% of it was transferred into the LC-MS/MS interface operated in positive electrospray ionization mode. The chromatographic run time was 2.0 min per injection. Atenolol and the internal standard, atenolol-d(7), showed a retention time of 1.0 min. The inter-day and intra-day precision and accuracy of the quality control samples were <5.3% relative standard deviation and <8.0% relative error, respectively. To explore the application of the current method for the analysis of other beta-blocking agents, propranolol and metoprolol were tested under the same chromatographic conditions with retention times of 0.68 and 0.75 min, respectively. The present method could be used for therapeutic drug monitoring, pharmacokinetic and drug--drug interaction studies of beta-blocking agents.  相似文献   
24.
This study aimed to develop an analytical method to determine the quantity of the impurity 3-aminopyridine (3AP). 3-Aminopyridine is a reactive reagent in the synthesis of linagliptin. The method was sensitive at level of 30.0 ppm of 3AP relative to linagliptin. The analysis was carried out using hydrophilic interaction liquid chromatography. The analytical column was Tracer Extrasil Silica (150 × 4.0 mm, 3 μm). A mobile phase of water–acetonitrile (10:90, v/v) containing 10.0 mM ammonium acetate was prepared and adjusted to pH 6.0. A UV detector was used to detect the amount of 3AP at a wavelength of 298 nm. Validation of the method was performed as per the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use in terms of detection limit, quantitation limit, linearity, accuracy, precision, specificity and robustness. The calibration curve was linear (r2 = 0.999) for 3AP concentration in the range of 30.0–450.0 ppm. This method showed a good sensitivity with a detection limit and a quantitation limit of 7.5 and 25.0 ppm, respectively.  相似文献   
25.
Several low volatile organic solvents were evaluated as organic modifiers in eluents for HILIC separations of cisplatin species to optimize the on-line coupling of HILIC to inductively coupled plasma MS (ICP-MS). The aim was to identify a solvent giving low solvent vapor loading of the ICP, to maximize analyte sensitivity and minimize carbon depositions on instrumental parts, while retaining chromatographic performance. The best overall performance of the HILIC-ICP-MS system for the analysis of cisplatin was achieved using 1,4-dioxane as eluent, yielding high retention and an HILIC type retention mechanism, at the expense of a 50% drop in column efficiency due to the higher viscosity of 1,4-dioxane compared to the more commonly used HILIC solvent ACN. Using 1,4-dioxane as solvent in HILIC provides the best compromise between carbon deposition and separation efficiency among a series of high-boiling water-miscible solvents tested.  相似文献   
26.
Nitric oxide (NO) is one of the most important mediators and neurotransmitters and its levels change under pathological conditions. NO production may be regulated by endogenous nitric oxide synthase (NOS) inhibitors, in particular asymmetric dimethylarginine (ADMA). Most of the interest is focused on ADMA, since this compound is present in plasma and urine and accumulation of ADMA has been described in many disease states but little is known about cerebrospinal fluid (CSF) concentrations of this compound and of its structural isomer symmetric dimethylarginine (SDMA). To determine the levels of methylarginines, we here present a new hydrophilic interaction chromatography (HILIC)-MS/MS method for the precise determination of these substances in CSF from microdialysis samples of rat prefrontal cortex (PFC). The method requires only minimal sample preparation and features isotope-labelled internal standards.  相似文献   
27.
This review represents a summary of the development and application of a novel mixed-mode HPLC approach to the separation and analysis of peptides and proteins termed hydrophilic interaction/cation-exchange chromatography (HILIC/CEX). This approach combines the most advantageous aspects of two widely different separation mechanisms, i.e. a separation based on hydrophilicity/hydrophobicity differences between polypeptides overlaid on a separation based on net charge. Applications described include HILIC/CEX separations of cyclic peptides, alpha-helical peptides, random coil peptides and modified or deletion products of synthetic peptides. In addition, the excellent resolving ability of HILIC/CEX for modified histone proteins is described. This approach is shown to represent an excellent complement to RP chromatography (RPC), as well as being a potent analytical tool in its own right.  相似文献   
28.
We report a column-switching liquid chromatography (LC) tandem mass spectrometry (MS/MS) method for highly sensitive determination of both free estrogens (estrone, estradiol, and estriol) and their conjugates (estrone-3-sulfate, estradiol-3-sulfate, estriol-3-sulfate, estrone-3-glucuronide, estradiol-3-glucuronide, estriol-16-glucuronide, and estriol-3-glucuronide) in river water. This technique combines reversed phase (RP) chromatographic separation of the dansyl chloride derivatized free estrogens and hydrophilic interaction liquid chromatographic (HILIC) separation of the estrogen conjugates with multiple reaction monitoring (MRM). Using this new method, sensitivity increases 100- to 1000-fold for free estrogens and 2- to 10-fold for estrogen conjugates over RPLC-MS/MS alone. Method detection limits (MDL) range from 0.038 to 6.9 ng L−1 with accuracy of 68-105% and precision of 1.7-17%. We successfully used this method to analyze river water samples collected from the North Saskatchewan River at the same location and detected trace concentrations of estrone (0.042 ng L−1) and estrone-3-sulfate (0.84 ng L−1), demonstrating the application of this method for environmental analysis.  相似文献   
29.
A simple and rapid detection method of oligosaccharides using high-performance liquid chromatography with a charged aerosol detection (HPLC-CAD) was studied. The direct detection of a sialylglycopeptide (SGP) derived from egg yolk was accomplished by HPLC-CAD using an amido-silica column, and its limit of detection was 0.40 pmol [signal-to-noise ratio (S/N) = 3]. The sensitivity of this method was lower than that of the fluorescence detection; however, the method showed approximately 5 times higher sensitivity than that using the conventional UV absorbance detection. Furthermore, this method was used for the analysis of the acid hydrolysis products of SGP. Monosialo- and asialo-oligosaccharides as well as free sialic acid were detected without using fluorescent derivatization. These results indicate that the present method is a new tool for the analysis of oligosaccharides.  相似文献   
30.
范广宇  冯峰  张峰  高飞  李晓明  梁振纲 《色谱》2018,36(4):351-355
建立了亲水相互作用色谱-三重四极杆质谱(HILIC-MS/MS)同时测定液体食品中6种人工合成甜味剂和8种甜菊糖苷类天然甜味剂的分析方法。样品经Waters Xbridge Amide色谱柱(150 mm×5.0 mm,3.5 μm)分离,以乙腈-10 mmol/L甲酸铵溶液(65:35,v/v)为流动相,流速为0.4 mL/min,柱温为35℃,然后以电喷雾电离(ESI)源,在多反应监测(MRM)、负离子模式下进行三重四极杆质谱检测。14种甜味剂在各自的范围内线性关系良好,相关系数均大于0.995,检出限为0.03~0.7 mg/kg,定量限为0.1~2.2 mg/kg。在2、5和20 mg/kg添加水平下,14种甜味剂的平均回收率为80.8%~108.7%,相对标准偏差为1.5%~7.7%(n=6)。该方法样品前处理操作简单,准确度高,灵敏度高,可用于液体食品中14种甜味剂的同时测定。  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号