In the absence of any special luminescence reagent, emission of weak chemiluminescence has been observed during the decomposition of hydrogen peroxide catalyzed by copper(II) in basic aqueous solution. The intensity of the chemiluminescence was greatly enhanced by addition of DNA and was strongly dependent on DNA concentration. Based on these phenomena, a flow-injection chemiluminescence method was established for determination of DNA. The chemiluminescence intensity was linear with DNA concentration in the range 2×10–7–1×10–5 g L–1 and the detection limit was 4.1×10–8 g L–1 (S/N=3). The relative standard deviation was less than 3.0% for 4×10–7 g L–1 DNA (n=11). The proposed method was satisfactorily applied for determination of DNA in synthetic samples. The possible mechanism of the CL reaction is discussed. 相似文献
The use of grape tissue as a source of catalase for the determination of hydrogen peroxide is reported. A slice of grape tissue attached to the membrane of a Clark-type oxgen sensor was used to monitor the oxidation of hydrogen peroxide by catalase. At the steady state, the sensor responds linearly to hydrogen peroxide in the concentration range 1 × 10?5–5 × 10?4 M. The response time (T90) was of the order of 1 min for this sensor. No interference was observed from ethanol, amino acids, glucose and lactic acid. The long-term stability of the grape tissue sensor was much better than previously reported immobilized enzyme and liver tissue-based hydrogen peroxide sensors. 相似文献
Summary Epoxidation of natural terpene (+)-carvone by the system consisting of a catalyst, oxalic acid (co-catalyst) and H2O2 (70% aqueous solution; oxidant) was studied and factorial design methods were applied for the optimization of this reaction.
A dinuclear manganese(IV) complex [LMn(O)3MnL](PF6)2 (L = 1,4,7-trimethyl-1,4,7-triazacyclononane) was used as a catalyst, and acetonitrile was employed as a solvent. An analysis
by methods of the complete 24 factorial design showed that an increase in the catalyst concentration gives a strong positive effect on the carvone conversion
and selectivity. Hydrogen peroxide has a smaller positive effect on the conversion, but at high concentration, H2O2 leads to some decrease in the selectivity. An increase in the oxalic acid concentration has a beneficial effect on the conversion,
but does not affect the selectivity. 相似文献
The third generation amperometric biosensor for the determination of hydrogen peroxide (H2O2) has been described. For the fabrication of biosensor, o-aminobenzoic acid (oABA) was first electropolymerized on the surface of platinum (Pt) electrode as an electrostatic repulsion layer to reject interferences. Horseradish peroxidase (HRP) absorbed by nano-scaled particulate gold (nano-Au) was immobilized on the electrode modified with polymerized o-aminobenzoic acid (poABA) with L-cysteine as a linker to prepare a biosensor for the detection of H2O2. Amperometric detection of H2O2 was realized at a potential of +20 mV versus SCE. The resulting biosensor exhibited fast response, excellent reproducibility and sensibility, expanded linear range and low interferences. Temperature and pH dependence and stability of the sensor were investigated. The optimal sensor gave a linear response in the range of 2.99×10^-6 to 3.55×10^-3 mol·L^-1 to H2O2 with a sensibility of 0.0177 A·L^-1·mol^-1 and a detection limit (S/N = 3) of 4.3×10^-7 mol·L^-1. The biosensor demonstrated a 95% response within less than 10 s. 相似文献
A novel, highly sensitive, selective, and simple kinetic method was developed for the determination of Mo(VI) based on its catalytic effect on the oxidation of 1-amino-2-naphthol-4-sulfonic acid (ANSA) with H2O2. The reaction was followed spectrophotometrically by tracing the oxidized product at 465 nm after 30 min of mixing the reagents. The optimum reaction conditions were: 10 mmol l−1 ANSA, 50 mmol l−1 H2O2, 100 mmol l−1 acetate buffer of pH 5.0 ± 0.05 and at 40 °C. Addition of 200 μg ml−1 diethylenetriaminepentaacetic acid (DTPA) conferred high selectivity for the proposed method. Following the recommended procedure, Mo(VI) could be determined with a linear calibration graph up to 2.5 ng ml−1 and a detection limit, based on the 3Sb-criterion, of 0.027 ng ml−1. The unique sensitivity and selectivity of the implemented method allowed its direct application to the determination of Mo(VI) in natural and industrial waste water. The method was validated by comparison with the standard ETAAS method. Moreover, published catalytic-spectrophotometric methods for the determination of molybdenum were reviewed. 相似文献
We have prepared several new iron(III) complexes with ligands which contain a phenol group; these are tetradentate [(X-phpy)H, X and H(phpy) represent the substituents on the phenol ring and N,N-bis(2-pyridylmethyl)-N-(2-hydroxybenzyl)amine, respectively] and pentadentate ligands [(R-enph-X)H; R=ethyl(Et) or methyl(Me) derivative and H(Me-enph) denotes N,N-bis(2-pyridylmethyl)-N″-methyl-N″-(2″-hydroxyl-benzylamine)ethylenediamine] and have determined the crystal structures of Fe(phpy)Cl2, Fe(5-NO2-phpy)Cl2, and Fe(Me-enph)ClPF6, which are of a mononuclear six-coordinate iron(III) complex with coordination of one or two chloride ion(s). These compounds are highly colored (dark violet) due to the coordination of phenol group to an iron(III) atom. When hydrogen peroxide was added to the solution of the iron(III) complex, a color change occurs with bleaching of the violet color, indicating that oxidative degradation of the phenol moiety occurred in the ligand system. The bleaching of the violet color was also observed by the addition of t-butylhydroperoxide. The rate of the disappearance of the violet color is highly dependent on the substituent on the phenol ring; introduction of an electron-withdrawing group in the phenol ring decreases the rate of bleaching, suggesting that disappearance of the violet band should be due to a chemical reaction between the phenol group and a peroxide adduct of the iron(III) species with an η1-coordination mode and that in this reaction the peroxide adduct acts as an electrophile towards phenol ring. The intramolecular interaction between the phenol moiety and an iron(III)-peroxide adduct may induce activation of the peroxide ion, and this was supported by several facts that the solution containing an iron(III) complex and hydrogen peroxide exhibits high activities for degradation of nucleosides and albumin. 相似文献
An automated analysis system is described for the measurement of hydrogen peroxide based on a chemiluminescence reaction with phenyl 10-methylacridinium-9-carboxylate (PMAC). A reversed FIA experimental arrangement is used to establish the operating conditions for the measurement of submicromolar levels of hydrogen peroxide. The carrier stream consists of hydrogen peroxide standards prepared in a pH 9.0, boric acid buffer and the flow rate for this carrier/sample stream is 4 ml/min. Twenty microliters of a 10 mM PMAC solution, prepared in a pH 3 phosphate buffer, are injected into the carrier/sample stream. Hydrogen peroxide mixes with the PMAC reagent in an incubation coil that is constructed by wrapping 107 cm of polyethylene tubing around a 1 cm o.d. plastic rod. The chemiluminescence reaction is then initiated by adding base just before the sample passes in front of a photomultiplier tube (PMT) detector. The calculated limit of detection (S/N = 3) for hydrogen peroxide is 0.25 M. In addition, the pH dependent hydrolysis of the PMAC reagent is characterized by an HPLC method which has been specifically developed for the separation and detection of the hydrolysis products of PMAC. Results indicate that a pH of 3.0 is required for long term stability of the PMAC reagent. Finally, this system has been successfully extended to the measurement of glutamate by coupling a bioreactor column of glutamate oxidase with the hydrogen peroxide detection scheme. A detection limit (S/N = 3) of 0.5 M has been established for glutamate with a throughput of 200 samples per hour. 相似文献
An acid urease column was applied to a fluorometric flow-injection analysis (FIA) system as a recognition element for determination of urea in rice wines.
The acid urease has specific properties of showing its catalytic activity in low pH range and tolerance to ethanol in comparison to those of a urease from jack-beans. The enzymes were covalently immobilized onto porous glass beads with controlled pore size and then, packed into a small polymer column. The flow-type of the biosensing system was assembled with a sample injection valve, the immobilized enzyme column, and a flow-through quartz cell attached to a fluorescent spectrophotometer. Citrate buffer (50 mM, pH 5.0) as the carrier solution was continuously pumped through the system. Sample solutions were introduced into the system via a rotary injection valve. A standard urea solution was measured through monitoring variations in fluorescent intensity attributable to fluorescent isoindole derivatives formed by coupling with ammonia molecules released in the enzymatic hydrolysis of urea and orthophthalaldehyde reagents. The fluorescent intensity was measured under the conditions of λex = 415 nm and λem = 485 nm. A wide, linear relationship was obtained between the concentration of urea (1.0–100 μM) and the variation in fluorescent intensity. The monitoring did not suffer from ethanol and various amino acids contained in rice wines. Real samples pretreated with ion exchange resins for removal of endogenous ammonia were introduced into the FIA system and urea in the samples was determined. These results were compared with those obtained with use of an F-kit method. The proposed FIA system should present sensitive, selective and convenient analysis of urea in alcoholic beverages. 相似文献