In vivo diffusion tensor imaging (DTI) of rat cervical and thoracic spinal cord was performed using a three-element phased array coil at 7 T. The magnetic field was shimmed over the spinal cord in real time using an in-house developed automatic algorithm. Echo planar imaging (EPI)-based diffusion-weighted images (DWIs) were acquired with 21 gradient encoding directions. The DWIs were tensor encoded, and diffusion tensor metrics, fractional anisotropy (FA), mean diffusivity (MD), longitudinal diffusivity (λ0) and transverse diffusivity (λ) were determined for both white matter (WM) and gray matter (GM). The results on six normal rats indicated no significant differences in the diffusion tensor metrics between thoracic and cervical regions. However, the DTI-derived metrics in cervical spinal cord from our study are somewhat different from the published results in rats. The possible reasons for these differences are suggested. 相似文献
A strip-shield inserted between a high inductance double-tuned solenoid coil and the glass tube containing the sample improves the efficiency of probes used for high-field solid-state NMR experiments on lossy aqueous samples of proteins and other biopolymers. A strip-shield is a coil liner consisting of thin copper strips layered on a PTFE (polytetrafluoroethylene) insulator. With lossy samples, the shift in tuning frequency is smaller, the reduction in Q, and RF-induced heating are all significantly reduced when the strip-shield is present. The performance of 800 MHz 1H/15N and 1H/13C double-resonance probes is demonstrated on aqueous samples of membrane proteins in phospholipid bilayers. 相似文献
Comparing the performance of different counter-current chromatography (CCC) J-type centrifuges has and will always be difficult. This is due to the number of variables such as speed of rotation, swung radius, β-value, column bore, column length that can be chosen during the design of an instrument. This situation is further complicated by the implication that some of these variables are intrinsically linked, such that if one is changed another or others can also change. The chromatographer has no influence on these hardware parameters once the instrument designer has chosen them. However, the chromatographer wants a CCC column that retains the most liquid stationary phase in order to achieve the best separation of the components in a mixture. What matters most is column performance in terms of: sample loading per injection, speed of separation, purity of target and yield of target. The instrument that has the best performance in all these areas is called a “high-performance” CCC system. This paper demonstrates to the modern chromatographer that a “high-performance” CCC instrument has shorter, lower volume columns that are rotated faster to provide quicker separations, even with the same sample loading. 相似文献
Dumbbell‐shaped amphiphiles based on an elongated rod segment can self‐assemble into planar networks with in‐plane hexagonally ordered pores in aqueous solution. On increasing temperature, the 2D networks change into hollow capsules passing through the closed sheets as an intermediate structure due to a LCST behavior of the oligoether dendritic exterior. The primary driving force for this interesting feature seems to originate from a consequence of the energy balance between hydrophobic interactions of anisotropic rod segments and alkyl chains, and repulsive interactions between dissimilar blocks. This dynamic structural variation triggered by external stimuli in a self‐assembling system can provide a useful strategy to create smart supramolecular materials and biomimetic systems.
In this paper, an approach to the design of shielded radio-frequency (RF) phased-array coils for magnetic resonance imaging (MRI) is proposed. The target field method is used to find current densities distributed on primary and shield coils. The stream function technique is used to discretize current densities and to obtain the winding patterns of the coils. The corresponding highly ill-conditioned integral equation is solved by the Tikhonov regularization with a penalty function related to the minimum curvature. To balance the simplicity and smoothness with the homogeneity of the magnetic field of the coil’s winding pattern, the selection of a penalty factor is discussed in detail. 相似文献