首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   178篇
  免费   8篇
  国内免费   25篇
化学   150篇
力学   2篇
综合类   1篇
数学   5篇
物理学   53篇
  2023年   2篇
  2022年   6篇
  2021年   6篇
  2020年   3篇
  2019年   7篇
  2018年   2篇
  2017年   8篇
  2016年   8篇
  2015年   3篇
  2014年   8篇
  2013年   12篇
  2012年   16篇
  2011年   17篇
  2010年   14篇
  2009年   26篇
  2008年   16篇
  2007年   16篇
  2006年   12篇
  2005年   9篇
  2004年   8篇
  2003年   6篇
  2002年   2篇
  2001年   1篇
  2000年   1篇
  1999年   1篇
  1998年   1篇
排序方式: 共有211条查询结果,搜索用时 688 毫秒
51.
Review: Aptamers in microfluidic chips   总被引:1,自引:0,他引:1  
This review, covering reports published from 2002 to August 2010, shows how aptamers have made significant contributions in the improvements of microfluidic chips for affinity extraction, separations and detections. Furthermore, microfluidic chip methods for studying aptamer-target interactions and performing aptamer selections have also been summarized. Accordingly, research vacancies and future development trends in these areas are discussed.  相似文献   
52.
Single- and multi-analyte detection of two gonadotropic hormones (follicle stimulating hormone (hFSH) and luteinizing hormone (hLH)) was achieved by a Surface Plasmon Resonance (SPR) immunoassay on untreated human urine samples. Multi-analyte detection was accomplished using two alternative formats which are based in the individual or simultaneous immobilization of the hormones on the sensor surface. The lowest detection limit for both hormones in urine was found to be 1 ng mL−1, which in international units (IU) in terms of the World Health Organization (WHO) standards represents 8 mIU mL−1 of hLH and 14 mIU mL−1 of hFSH, respectively. The reliability of the assay was demonstrated by intra- and inter-assay variabilities <6%, chip-to-chip variabilities <5%, recoveries in the range of 80-120% and stability of the sensor response through more than 100 measurements. The sensitivity of this biosensing methodology renders it in a useful technique for the diagnosis of reproductive disorders, as well as for fertility monitoring.  相似文献   
53.
This paper introduces strategies for enhancement of a surface plasmon resonance (SPR) signal by adopting colloidal gold nanoparticles (AuNPs) and a SiO2 layer on a gold surface. AuNPs on SiO2 on a gold surface were compared with an unmodified gold surface and a SiO2 layer on a gold surface with no AuNPs attached. The modified surfaces showed significant changes in SPR signal when biomolecules were attached to the surface as compared with an unmodified gold surface. The detection limit of AuNPs immobilized on a SPR chip was 0.1 ng mL−1 for the prostate-specific antigen (PSA), a cancer marker, as measured with a spectrophotometer. Considering that the conventional ELISA method can detect ∼10 ng mL−1 of PSA, the strategy described here is much more sensitive (∼100 fold). The enhanced shift of the absorption curve resulted from the coupling of the surface and particle plasmons by the SiO2 layer and the AuNPs on the gold surface.  相似文献   
54.
Octadecanethiol (ODT) self-assembled monolayer (SAM) prepared onto gold-coated glass plate has been modified by using nitrene reaction of 1-fluoro-2-nitro-4-azidobenzene (FNAB) that further covalently binds to cholesterol oxidase (ChOx) via thermal reaction. FNAB acts as a bridge (cross-linker) between SAM and ChOx. The ChOx/FNAB/ODT/Au electrode thus fabricated has been characterized using contact angle (CA) measurements, UV-vis spectroscopy, electrochemical techniques and X-ray photoelectron spectroscopy (XPS) technique, respectively. This ChOx/FNAB/ODT/Au bioelectrode has been utilized for estimation of cholesterol in solution using surface plasmon resonance (SPR) technique. This SPR based cholesterol biosensor has linearity from 50 to 500 mg/dl of cholesterol in solution with lower detection limit of 50 mg/dl and shelf life of about 2 months when stored at 4 °C.  相似文献   
55.
Mauriz E  Calle A  Montoya A  Lechuga LM 《Talanta》2006,69(2):359-364
A portable surface plasmon resonance (SPR) optical biosensor device is described as a direct immunosensing system to determine organic pollutants in natural water samples. Monitoring of organochlorine (DDT), organophosphorus (chlorpyrifos) and carbamate (carbaryl) compounds within the concentration levels stipulated by the European legislation, can be accomplished using this immunosensor. The lowest limit of detection (LOD) was obtained for DDT, at 20 ng L−1, whilst 50 ng L−1 and 0.9 μg L−1, were achieved for chlorpyrifos and carbaryl, respectively. Matrix effects were evaluated for the carbaryl immunoassay in different water types with detection limits within the range of carbaryl standard curves in distilled water (0.9-1.4 μg L−1). The covalent immobilization of the analyte derivative through an alkanethiol self-assembled monolayer (SAM) allowed the reusability of the sensor surface during more than 250 regeneration cycles. The quality of the regeneration was proved over a 1-month period of continuous working. The analysis time for a complete assay cycle, including regeneration, comprises 24 min. Our portable SPR-sensor system is already a market product, commercialized by the company SENSIA, SL. The size and electronic configuration of the device allow its portability and utilization on real contaminated locations.  相似文献   
56.
Li Hua CHEN 《中国化学快报》2006,17(12):1619-1622
Recently, surface plasmon resonance (SPR) become more and more popular without the need of the label technology1-3. However, sometimes, a number of experimental artifacts complicate the final biosensor analysis4-7. The utilization of a reference surface c…  相似文献   
57.
A laboratory-made surface plasmon resonance (SPR) instrument based on the detection of resonance excitation wavelength has been successfully fabricated. The performance and workability of the SPR instrument was demonstrated as a DNA biosensor. Biotinylated single-stranded oligonucleotides (ssDNA) were chemically immobilized on a gold-film surface of the SPR instrument as a DNA probe for the detection of its fully complementary, half-complementary and non-complementary ssDNA. The immobilization of the ssDNA probe was done by avidin-biotin linkage. The ssDNA used were 12-mer oligonucleotides. The sensing mechanism was based on the shift in resonance wavelength of an excitation light beam as the target ssDNA hybridized with the ssDNA on the gold-film surface. The linear dynamic ranges of the DNA biosensor for fully complementary and half-complementary ssDNA are 0.04-1.2 pM and 0.08-1.1 pM, respectively. The DNA biosensor showed higher sensitivity to fully complementary ssDNA than to half-complementary ssDNA. But no shift of resonance wavelength to the non-complementary ssDNA was observed.  相似文献   
58.
Au nanoparticles dispersed ZrO2 thin films were prepared from two precursors HAuCl4·4H2O and ZrOCl2·8H2O in air. The structural properties and size of Au particle in ZrO2 film were characterized by X-ray diffraction (XRD) and transmission electron microscopy (TEM). The surface analysis with atomic force microscopy (AFM) showed the effect of monoethanolamine on preventing the migration of Au particles to the surface. The absorption peak of Au particles by the surface plasma resonance was observed and the red shift of absorption peak was discussed.  相似文献   
59.
This work concerns the ultraconvergence of quadratic finite element approximations of elliptic boundary value problems. A new, discrete least-squares patch recovery technique is proposed to post-process the solution derivatives. Such recovered derivatives are shown to possess ultraconvergence. The keys in the proof are the asymptotic expansion of the bilinear form for the interpolation error and a “localized” symmetry argument. Numerical results are presented to confirm the analysis.  相似文献   
60.
Interaction of straight chain alcohol vapors with MOF-199-functionalized films was studied by SPR.The signals had linear relationships with the concentration of alcohols over a wide range from 0 to 70%(v/v) and were reversible in proportional to the chain length,with R~2 all above 0.99.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号