首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   36篇
  免费   1篇
化学   34篇
物理学   3篇
  2020年   1篇
  2019年   1篇
  2018年   2篇
  2016年   1篇
  2015年   2篇
  2014年   2篇
  2013年   2篇
  2012年   1篇
  2011年   5篇
  2010年   5篇
  2009年   5篇
  2008年   3篇
  2006年   2篇
  2005年   1篇
  1999年   2篇
  1997年   1篇
  1982年   1篇
排序方式: 共有37条查询结果,搜索用时 78 毫秒
11.
12.
We demonstrate the potential of Raman spectroscopy to detect cocaine concealed inside transparent glass bottles containing alcoholic beverages. A clear Raman signature of cocaine with good signal-to-noise was obtained from a ∼300 g solution of adulterated cocaine (purity 75%) in a 0.7 L authentic brown bottle of rum with 1 s acquisition time. The detection limit was estimated to be of the order of 9 g of pure cocaine per 0.7 L (∼0.04 moles L−1) with 1 s acquisition time. The technique holds great promise for the fast, non-invasive, detection of concealed illicit compounds inside beverages using portable Raman instruments, thus permitting drug trafficking to be combated more effectively.  相似文献   
13.
A new cut-off criterion has been proposed for the selection of uninformative variables prior to chemometric partial least squares (PLS) modelling. After variable elimination, PLS regressions were made and assessed comparing the results with those obtained by PLS models based on the full spectral range. To assess the prediction capabilities, uninformative variable elimination (UVE)-PLS and PLS were applied to diffuse reflectance near-infrared spectra of heroin samples. The application of the proposed new cut-off criterion, based on the t-Students distribution, provided similar predictive capabilities of the PLS models than those obtained using the original criteria based on quantile value. However, the repeatability of the number of selected variables was improved significantly.  相似文献   
14.
This work details a rapid analytical method using direct sample injection for the simultaneous identification/quantification of 22 drugs of abuse, including some of their major metabolites, in environmental samples. This has been developed using a hybrid triple quadrupole-linear ion trap-mass spectrometer (QqLIT). With the increasing sensitivity of today's tandem mass spectrometers, direct injection analysis of water samples has become an attractive alternative to traditional analytical protocols, which often include a preliminary pre-concentration step. What's more, this kind of analysis is in accordance with many of the main objectives of so-called green analytical chemistry, or environmentally friendly practice. The analytical performance of the LC-MS/MS method was evaluated in three different water matrices (surface water, influent and effluent wastewater). Data acquisition was carried out in selected reaction monitoring (SRM) mode under time-scheduled conditions, monitoring two SRM transitions for simultaneous identification/quantification of all target compounds in the samples. Additionally, an experiment was performed using the information-dependent acquisition (IDA) scan to carry out the identification of those analytes for which the second transition was present at a low intensity. Finally, the two methodologies developed were applied to real samples for evaluation.  相似文献   
15.
《Electrophoresis》2018,39(17):2188-2194
This study describes the development of a new analytical method for the separation and detection of cocaine (COC) and its adulterants, or cutting agents, using microchip electrophoresis (ME) devices coupled with capacitively coupled contactless conductivity detection (C4D). All the experiments were carried out using a glass commercial ME device containing two pairs of integrated sensing electrodes. The running buffer composed of 20 mmol/L amino‐2‐(hydroxymethyl) propane‐1,3‐diol and 10 mmol/L 3,4‐dimethoxycinnamic acid provided the best separation conditions for COC and its adulterants with baseline resolution (R > 1.6), separation efficiencies ranging from (2.9 ± 0.1) to (3.2 ± 0.2) × 105 plates/m, and estimated LOD values between 40 and 150 μmol/L. The quantification of COC was successfully performed in four samples seized by the Brazilian Federal Police Department and all predicted values agree with values estimated by the reference method. Some other interfering species were detected in the seized samples during the screening procedure on ME–C4D devices. While lidocaine was detected in sample 3, the presence of levamisole was observed in samples 2 and 4. However, their concentrations were estimated to be below the LOQ. ME–C4D devices have proved to be quite efficient for the identification and quantification of COC with errors lower than 10% when compared to the data obtained by a reference method. The approach herein reported offers great potential to be used for on‐site COC screening in seized samples.  相似文献   
16.
A method based on separation by capillary electrophoresis combined with UV-laser-induced fluorescence detection (Lambdaex = 266 nm) was developed for the determination of nine tryptamine derivatives of forensic interest and potential matrix constituents. The composition of the separation electrolyte was optimized with respect to the resolution of solutes of interest and to the sensitivity of fluorescence detection. Native alpha-cyclodextrin was employed as a complex forming modifier of the electrophoretic separation and fluorescence-enhancing agent. With the help of a stacking procedure, limits of detection of 0.1-6 microg/L for all analytes were obtained. The repeatability for the peak area (at a concentration of the analyte about 100 times the LOD) was less than 2.3% RSD. A second HPLC method was developed, and its analytical parameters were evaluated for an estimation of the accuracy of the CE-LIF method and for method comparison. The results of the determination of tryptamine derivatives in the samples of forensic interest obtained with the two independent methods are in good agreement.  相似文献   
17.
《Analytical letters》2012,45(6):925-948
Abstract

Saliva is an excellent analytical matrix for the detection of illicit drug residues such as tetrahydrocannabinol and amphetamine. Analysis of drugs in saliva offers significant advantages compared to blood or urine. These include ease of sample collection, reduced sample processing and greater accessibility for collection. However to fully exploit its potential knowledge of the physiology and of saliva, salivary drug metabolism, optimal collection strategies, rapid, sensitive and specific assays and possible interferences is required. The method selected for sample collection can also have a significant impact on the validity of the testing method. This review critically analyses these factors, the current approaches used and potential future developments in salivary drug analysis.  相似文献   
18.
A confirmatory method for the determination of illicit drugs based on micro-solid phase extraction with modified tips, made of a functionalized fiberglass with apolar chains of octadecylsilane into monolithic structure, has been developed in this study. Drugs belonging to different chemical classes, such as amphetamine, methamphetamine, methylenedioxyamphetamine, methylenedioxyethylamphetamine, methylenedioxymethylamphetamine, cocaine, benzoylecgonine, ketamine, mescaline, phencyclidine and psilocybine were analyzed. The quantitation was performed by liquid chromatography-tandem mass spectrometry and the analytes were detected in positive ionization by means of an electrospray source. The limits of quantification ranged between 0.3 ng mL−1 for cocaine and 4.9 ng mL−1 for psilocybine, with coefficients of determination (r2) >0.99 for all the analytes as recommended in the guidelines of Society of Forensic Toxicologists-American Association Forensic Sciences.  相似文献   
19.
Meng P  Fang N  Wang M  Liu H  Chen DD 《Electrophoresis》2006,27(16):3210-3217
Cation-selective exhaustive injection (CSEI) is used as an on-line concentration method for the high-sensitivity analysis of illicit amphetamines using CE. Optimum conditions for the determination of amphetamine, methamphetamine and methylenedioxy-methamphetamine were investigated. Sodium dodecyl sulfate (25 mM) in 100 mM phosphate buffer (pH 2.9) with 20% methanol as organic additive was used as the background electrolyte for CE separation. The LOD, based on an S/N of 3:1, was about 0.01 microg/mL using normal capillary micellar electrokinetic chromatography, while by using CSEI in combination with micellar sweeping the sensitivity increased up to 1000-fold with the LOD lower than 50 pg/mL. The reproducibility of CSEI combined with micellar sweeping for analyzing amphetamines was satisfactory (relative standard deviation around 10% by using area ratios against an internal standard). This method is highly sensitive and can be used to analyze trace amount amphetamines in human hair.  相似文献   
20.
Forensic analysis is an important branch of modern Analytical Chemistry with many legal and socially relevant implications. Biosensors can play an important role as efficient tools in this field considering their well known advantages of sensitivity, selectivity, easy functioning, affordability and capability of miniaturization and automation. This article reviews the latest advances in the use of biosensors for forensic analysis. The different methodologies for the transduction of the produced biological events are considered and the applications to forensic toxicological analysis, classified by the nature of the target analytes, as well as those related with chemical and biological weapons critically commented. The article provides several Tables where the more relevant analytical characteristics of the selected reported methods are gathered.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号