61.
The electrochemical determination of iodide was studied at boron-doped diamond thin film electrodes (BDD) using cyclic voltammetry (CV) and flow-injection (FI) analysis, with amperometric detection. Cyclic voltammetry of iodide was conducted in a phosphate buffer pH 5. Experiments were performed using glassy carbon (GC) electrode as a comparison. Well-defined oxidation waves of the quasi-reversible cyclic voltammograms were observed at both electrodes. Voltammetric signal-to-background ratios (S/B) were comparable. However, the GC electrode gives much greater in the background current as usual. The potential sweep rate dependence exhibited that the peak current of iodide oxidation at 1 mM varied linearly (r2 = 0.998) with the square root of the scan rate, from 0.01 to 0.30 V s−1. This result indicates that the reaction is a diffusion-controlled process with negligible adsorption on BDD surface, at this iodide concentration. Results of the flow-injection analysis show a highly reproducible amperometric response. The linear working range was observed up to 200 μM (r2 = 0.999). The detection limit, as low as 0.01 μM (3σ of blank), was obtained. This method was successfully applied for quantification of iodide contents in nuclear emergency tablets.  相似文献   
62.
A flow-injection electrochemical immunoassay system based on a disposable immunosensor for the determination of interleukin-6 (IL-6) was proposed. The immunosensor was prepared by entrapping horseradish peroxidase (HRP)-labeled IL-6 antibody into gold nanoparticles-modified composite membrane at a screen-printed graphite electrode. With a non-competitive immunoassay format, the immunosensor was inserted in the flow system with an injection of sample, and the injected sample containing IL-6 antigen was produced transparent immunoaffinity reaction with the immobilized HRP-labeled IL-6 antibody. The formed antigen–antibody complex inhibited partly the active center of HRP, and decreased the immobilized HRP to H2O2 reduction. The performance and factors influencing the performance of the immunosensor were investigated. Under optimal conditions, the current change obtained from the labeled HRP relative to thionine–H2O2 system was proportional to the IL-6 concentration in the range of 5–100 ng L−1 with a detection limit of 1.0 ng L−1 (at 3δ). The flow-injection immunoassay system could automatically control the incubation, washing and measurement steps with acceptable reproducibility and good stability. Moreover, the proposed immunosensors were used to analyze IL-6 in human serum specimens. Analytical results of clinical samples show the developed immunoassay has a promising alternative approach for detecting IL-6 in the clinical diagnosis.  相似文献   
63.
In this paper, a new chemiluminescence phenomenon described as the second chemiluminescence emission was observed when menadione sodium bisulfite was injected into a reaction mixture of luminol and potassium periodate, in which luminol was oxidized by excess amount of potassium periodate for about 24 h. The mechanism of the second chemiluminescence emission was proposed based a series of experiments. Moreover, our experiment discovered that the second chemiluminescence intensity was a linear function of the concentration of menadione sodium bisulfite in the range of 2 × 10−9 to 4 × 10−5 g L−1. Based on this phenomenon, a new flow-injection method for the determination of menadione sodium bisulfite has been established.  相似文献   
64.
p-Nitrophenyl phosphate is one of the most widely used substrates for alkaline phosphatase in ELISAs because its yellow, water-soluble product, p-nitrophenol, absorbs strongly at 405 nm. p-Nitrophenol is also electroactive; an oxidative peak at 0.97 V (vs. an Ag pseudoreference electrode) is obtained when a bare screen-printed carbon electrode is used. When an amperometric detector was coupled to a flow-injection analysis system the detection limit achieved for p-nitrophenol was 2×10−8 mol L−1, almost two orders of magnitude lower than that obtained by measuring the absorbance of the compound. By use of this electrochemical detection method, measurement of 7×10−14 mol L−1 alkaline phosphatase was achieved after incubation for 20 min. The feasibility of coupling immunoassay to screen-printed carbon electrode amperometric detection has been demonstrated by performing an ELISA for detection of pneumolysin, a toxin produced by Streptococcus pneumoniae, which causes respiratory infections. The method is simple, reproducible, and much more sensitive than traditional spectrophotometry.  相似文献   
65.
Rosanna Toniolo 《Talanta》2010,80(5):1809-3397
A sensitive and fast responding electrochemical sensor is described for the determination of free and total sulphur dioxide in wines and grape juices which prevents interferences coming from ethanol and other natural components. It consists of a cell provided with a porous gold working electrode supported on one face of an ion-exchange membrane, acting as a solid polymer electrolyte (SPE), which allows gaseous electroactive analytes to be detected. This sensor was used as an amperometric detector for a flow injection system in which controlled volumes of headspace equilibrated with samples were injected. This approach was adopted to make also possible the determination of total SO2, avoiding drawbacks caused by the high relative humidity generated by the sample heating resulting from the neutralization reaction of excess NaOH, whose addition was required to release sulphur dioxide from its combined forms. Factors affecting the detection process were examined and optimised. Under the identified optimal conditions, SO2 detection resulted in sharp peaks which allowed to infer detection limits for a signal-to-noise ratio of 3, referred to liquid samples, of 0.04 and 0.02 mg L−1 for free and total SO2 which were determined at 20 and 35 °C, respectively. Moreover, the responses were found to be characterized by good repeatability (±2% and ±4%, respectively) and linear dependence on the SO2 concentration over a wide range (0.2-500 mg L−1 for both free and total SO2). Finally, the long-term stability of the sensor turned out to be totally satisfactory in that responses changed of ±9% alone even after long periods of continuous use. The application to some commercial wines and grape juices is also presented.  相似文献   
66.
67.
The miniature flow injection analysis (μFIA) system is based on a mechanically engraved manifold in a PMMA-substrate. The channels have a trapezoidal cross-section with a depth of 150 μm and a width between 180 and 360 μm and the reactor volume is 3.75 μl. A light-emitting diode (LED) is used as radiation source for absorbance detection and optical fibres are used for transmitting light to and from the manifold. Computer controlled valves are used for directing the liquid flows maintained with syringe pumps. A sampling rate of approximately five determinations per minute was achieved with a reagent consumption of 10 μl min−1. Four applications were implemented and tested; the performance was found to be comparable to that obtained with conventional FIA-set-ups despite the drastically reduced optical pathlength. Electrokinetic pumping was extensively evaluated but found to generally be very restricted in scope because the reagent solutions cannot usually be adapted to the requirements for generating the flow.  相似文献   
68.
A modification of the Trautz-Schorigin reaction into a flow-injection analysis configuration is described. Different approaches were used at the optimization of chemiluminescence determination of formaldehyde in water based on the reaction of formaldehyde, gallic acid and hydrogen peroxide in an alkaline solution. Detection system with a 218 μl chemiluminescence cell was optimized by both a one-variable-at-a-time method, and a modified simplex method. A calibration graph is linear in the concentration range 4 × 10−8 to 1 × 10−5 M HCHO. The detection limit of formaldehyde for a signal-to-noise ratio of 3 is 4 × 10−8 M. The relative standard deviations for 15 repeated measurements of 1 × 10−6 and 5 × 10−6 mol l−1 HCHO are 4.32 and 3.33%, respectively. The analysis time is 1.5 min. The method was applied to the determination of formaldehyde in urban rainwater. A comparison of results found by proposed method with those obtained by fluorimetric reference method provided a good agreement.  相似文献   
69.
A miniaturized capillary electrophoresis (CE) system with UV-Vis detection was coupled to a flow injection (FI) system for achieving high throughput continuous sample introduction. The cassette of a commercial CE instrument was modified to hold a 6.5 cm long silica capillary and a flow-through waste reservoir. The cassette was inserted into the flow-cell chamber of a commercial UV detector, with the light beam focused on the capillary and collected by two ball lenses on the cassette. The capillary inlet, left outside the cassette and detector, was positioned on the top of a vertical 3.5 mm diameter glass rod, in close contact with an electrode. Samples injected through the FI system dropped freely on top of the pillar, covering the capillary inlet and electrode. Continuous sample introduction was achieved for CE separations under non-interrupted separation voltage, which was isolated from the FI system through the discontinuity of droplets. The newly developed interface and UV detection system was used for fast separation of sulphamethoxazole (SMZ) and trimethoprim (TMP) in sulphatrim tablets, achieving a high throughput of over 48 h−1, and a low carryover of 2%. Separation efficiencies of 8 μm plate height and detection limits of 1.0 mg l−1 for SMZ and 0.5 mg l−1 (3σ) for TMP were obtained.  相似文献   
70.
A simple, sensitive, low-cost and rapid, flow injection system for the on-line preconcentration of lead by sorption on a microcolumn packed with silica gel funtionalized with methylthiosalicylate (TS-gel) was developped. The metal is directly retained on the sorbent column and subsequently then eluted from it by EDTA. Five variables (sample flow rate, eluent flow rate, eluent concentration, pH and buffer concentration) were considered as factors in the optimization process. Interactions between analytical factors and their optimal levels were investigated using two level factorial and Box-Behnken designs. The optimum conditions established were applied to the determination of lead by flow injection inductively coupled plasma atomic emission spectrometry (FI-ICP-AES). The proposed method has a linear calibration range from 10 to at least 500 ng ml−1 of lead. At a sample frequency of 24 h−1 and a 120 s preconcentration time, the enrichment factor was 41, the detection limit was 15.3 ng ml−1 (S/N=3) and the precision, expressed as relative standard deviation, was 0.9% (at 100 ng ml−1). Validation of the developed method was carried out against electrothermal atomic absorption spectrometry analysis without statistically significant differences between the proposed method and the atomic absorption method.  相似文献   