首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   102篇
  免费   1篇
化学   25篇
物理学   78篇
  2023年   1篇
  2022年   1篇
  2020年   1篇
  2016年   7篇
  2015年   4篇
  2014年   16篇
  2013年   11篇
  2012年   4篇
  2011年   4篇
  2010年   2篇
  2009年   4篇
  2008年   5篇
  2007年   6篇
  2005年   4篇
  2004年   7篇
  2003年   4篇
  2002年   4篇
  2001年   4篇
  2000年   2篇
  1999年   1篇
  1997年   6篇
  1996年   1篇
  1993年   4篇
排序方式: 共有103条查询结果,搜索用时 15 毫秒
71.
High energy radiation treatment of foodstuff for microbial control and shelf-life extension is being used in many countries. However, for consumer protection and information, the European Union has adopted the Directives 1999/2/EC and 1999/3/EC to harmonize the rules concerning the treatment and trade of irradiated foods in EU countries. Among the validated methods to detect irradiated foods the EU directives also include Electron Paramagnetic Resonance (EPR/ESR) spectroscopy.We describe herein the use of EPR for identification of four species of bivalve mollusks, i.e. brown Venus shells (Callista chione), clams (Tapes semidecussatus), mussels (Mytilus galloprovincialis) and oysters (Ostrea edulis) irradiated with 60Co γ-rays. EPR could definitely identify irradiated seashells due to the presence of long-lived free radicals, primarily CO2, CO33−, SO2 and SO3 radical anions. The presence of other organic free radicals, believed to originate from conchiolin, a scleroprotein present in the shells, was also ascertained. The use of one of these radicals as a marker for irradiation of brown Venus shells and clams can be envisaged. We also propose a dosimetric protocol for the reconstruction of the administered dose in irradiated oysters.  相似文献   
72.
Intraocular cancer is a serious threat to the lives of those that suffer from it. Dosimetry for eye brachytherapy presents a significant challenge due to the inherently steep dose gradients that are needed to treat such small tumours in close proximity to sensitive normal structures. This issue is addressed by providing much needed quality assurance to eye brachytherapy, a novel volumetric dosimetry system, called Panoptes was developed. This study focuses on the preliminary characterisation and calibration of the system. Using ion beam facilities, the custom, pixelated silicon detector of Panoptes was shown to have good charge collection uniformity and a well defined sensitive volume. Flat-field calibration was conducted on the device using a 250 kVp orthovoltage beam. Finally, the detector and phantom were simulated with Monte Carlo in Geant4, to create water equivalent dose correction factors for each pixel across a range of angles.  相似文献   
73.
In the course of this work, the experimental energy dependence of the OSL material beryllium oxide was determined for different radiation qualities. With the help of the radiation transport program AMOS the experimental setup was simulated. The calculated energy response differs from the experimental energy response. There is an underestimation for low energy photons caused by local saturation effects. For radiation with higher LET local structures of the detector can be saturated. The deposited energy doesn't contribute to the OSL effect. The detected dose is lower. The ratio between experimental and simulated energy response is called OSL efficiency. Subsequently the results were used to generate a model of local saturation for calculating the efficiency for different irradiation conditions. With the help of the model predictions for the detection efficiency for photons and electrons in the common energy range for personal and environmental dosimetry, reaching from 10 keV up to some MeV, are possible. The efficiency for electrons decreases with falling energy continuously. Photons show a similar effect, but for energies ranging from 40 to 80 keV the efficiency increases with decreasing energy. This can be explained by the interaction effects of the photons with the detector material. The experimental and modeled detection efficiencies can be used to calculate the readout of a BeO-OSL detector from dose values determined with radiation transport programs.  相似文献   
74.
Currently, there are no radiation detectors that can be used for routine measurements of linear energy transfer (LET) in particle therapy clinics. In this work, we characterized the LET dependence of Al2O3:C optically stimulated luminescence (OSL) detectors (OSLDs) exposed to therapeutic proton beams in order to evaluate their potential for clinical LET measurements. We evaluated OSLDs that were irradiated with an absorbed dose to water of 0.2 Gy in therapeutic proton beams with average energies ranging between approximately 25 MeV and 200 MeV, resulting in LET in water values between 0.45 and 2.29 keV/μm. We examined two properties of the OSL emission signal in terms of LET dependence: the signal intensities of the blue and ultraviolet (UV) emission bands, and the shapes of the OSL curves. We found that the signal intensity of the UV emission band increased consistently with LET within the range investigated, whereas the intensity of the blue emission band remained constant. Our results also demonstrated that the OSL curve shapes were more LET dependent for signals containing both the blue and UV emission bands than for signals containing only one of the bands. Both metrics we examined in this study – the relative UV/blue emission signal intensities and OSL curve shapes – show potential for LET detection in proton therapy.  相似文献   
75.
This work evaluates the dosimetric properties of crystals of CaSO4 doped with unusual elements, such as europium (Eu) and silver (Ag), including their nanoparticle forms, after the incorporation of glass or Teflon and compares them with well-known thermoluminescent dosimeters (TLD). X-ray diffraction analyses showed that samples of doped CaSO4 exhibit only a single phase corresponding to the crystal structure of anhydrite. Optical spectroscopy confirmed the presence of Eu3+ in the crystal matrix and a luminescent gain due the presence of silver nanoparticles. The composites showed thermoluminescent emission glow curves, with a single peak centered at approximately 200 °C for pellets with Teflon and at 230 °C for pellets with glass. The dosimeters based on calcium sulfate doped with europium and silver nanoparticles provided the most intense thermoluminescent (TL) emission of the composites studied. In comparison with commercial TLD, such as LiF:Mg,Ti and CaSO4:Dy, the CaSO4:Eu,Ag(NP)+glass produced in this work presented similar low detection limits and higher sensitivity. The new methods for the preparation of dosimeters and the incorporation of glass are shown to be viable because all of the samples presented a linear, reproducible and first order kinetic TL emission.  相似文献   
76.
Luminescence models   总被引:3,自引:0,他引:3  
  相似文献   
77.
PurposeIn this study a dosimetric comparison utilizing continuous data acquisition and discrete data acquisition is examined using IBA Blue Phantom (IBA Dosimetry, Schwarzenbruck, Germany) and PTW (PTW, Freiberg, Germany) MP3-M water tanks. The tanks were compared according to several factors including set up time, ease of use, and data acquisition times. A tertiary objective is to study the response of several ionization chambers in the two tanks examined.MethodsMeasurements made using a Varian 23EX LINAC (Varian Medical Systems, Palo Alto, CA) include PDDs and beam profiles for various field sizes with IBA CC13, PTW Semiflex 31010, PTW Pinpoint N31016, and PTW 31013 ion chambers for photons (6, 18 MV) and electrons (6, 9, 12, 15, and 18 MeV). Radial and transverse profile scans were done at depths of maximum dose, 5 cm, 10 cm, and 20 cm using the same set of tanks and detectors for the photon beams. Radial and transverse profile scans were done at depth of maximum dose for the electron beams on the same tanks and chambers. Data processing and analysis was performed using PTW's MEPHYSTO Navigator software and IBA's OmniPro Accept version 6.6 for the respective water tank systems.ResultsPDD values agree to within 1% and dmax to within 1 mm for the PTW MP3-M tank using PTW 31010 and Blue Phantom using IBA CC13 chamber, respectively and larger discrepancy with the PTW PinPoint N31016 chamber at 6 MV. With respect to setup time the PTW MP3-M and IBA Blue phantom tank took about 20 and 40 min, respectively. Scan times were longer by 5–15 min per field size in the PTW MP3-M tank for the square field sizes from 1 cm to 40 cm as compared to the IBA Blue phantom. However, data processing times were higher by 7 min per field size with the IBA system.ConclusionsTank measurements showed little deviation with the higher energy photons as compared to the lower energy photons with regards to the PDD measurements. Chamber construction as well as tank set up may be causing the slight deviation in data. It is important to identify the exact source of the potential errors to ensure that proper tank usage is performed when making such measurements to ensure that patient safety is in compliance. Beam profiles done with different chambers and tanks showed little to no deviation from one to another. With regards to continuous versus discrete data measurements the main difference was in the data processing technique used. Discrete data obtained required less data processing as compared to the continuous data acquired.  相似文献   
78.
TL characteristics of powder form of Al2O3 doped with 0.1 mol% carbon and co-doped with different magnesium concentrations of 0.1 mol% and 0.2 mol% exposed to Cobalt-60 gamma ray at doses ranging from 5 Gy to 70 Gy were investigated. The recorded glow curves consist a dominant peak at 180 °C for a heating rate of 1 °C s−1. The TL sample with 0.2 mol% Mg concentration have higher response compared to the sample with 0.1 mol% Mg concentration for a delivered dose of 5 Gy. The TL response has linear relationship with delivered dose for both samples. The TL sensitivity was found as 277.9 nC mg−1 Gy−1 for the sample with Mg concentration 0.2 mol% and 128.2 nC mg−1 Gy−1 for 0.1 mol% Mg. However, the sample with 0.1 mol% Mg concentration has better fading properties compared to the sample with 0.2 mol% Mg concentration. Both samples show good reproducibility with value less than 13%. The experimental value of effective atomic number, Zeff is 9.21 and 9.44 for the sample with Mg concentration 0.1% mol and 0.2% mol, respectively, which are near to Zeff of bone with a value of about 11.6.  相似文献   
79.
In this work, the thermally stimulated luminescence (TSL) and persistent luminescence (PLUM) properties of praseodymium doped yttrium aluminum garnet (YAG:Pr3+) exposed to β-irradiation are reported. X-ray diffraction (XRD) confirms a single phase of YAG obtained by the combustion method. Transmission electron microscopy (TEM) shows that powder particles appear to be irregular crystals with an average size of 67 nm. TSL glow-curve deconvolution of YAG:Pr3+ after β-irradiation consist in six peaks centered at 394, 450, 467, 543, 637 and 705 K. The TSL fading and PLUM signals were found to be associated with at least with two different kinds of traps, corresponding to the peaks located at 394, 450 and 467 K. YAG:Pr3+ nanophosphors analyzed in this work showed interesting features about the dosimetric sensitivity as well as the reproducibility for both TSL/PLUM techniques, with good linearity dose response. These results indicate that nanocrystalline YAG:Pr3+ is a good candidate for dosimetric applications in the range of 80 mGy-20 Gy.  相似文献   
80.
The high dose standards and dissemination system of electron beams are being established at NIM. The graphite and/ or water calorimeters and liquid chemical dosimeter are to be accepted as standards. The transfer dosimeter selected are alanine/ESR dosimeter and radiochromic film (FWT - 60). Several kinds of radiochromic films, undyed cellulose triacetate, polyethylene and blue cellophane will be recommended as working dosimeter. A series of intercomparison studies are conducted between calorimeter and dichromate dosimeter. Agreement is found within 2%. Water calorimeters and dichromate dosimeters are used to make absolute dosimetric measurements of electron beams. These calibrated beams are then used to calibrate several types of dosimeters, such as alanine, radiochromic films, undyed and dyed polyethylene. Preliminary studies show that water calorimeter and dichromate dosimeter are reproducible and sufficiently accurate for electron beam calibration. The estimated overall uncertainty of the measurement is better than 5% at 95% confidence level.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号