首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   102篇
  免费   1篇
化学   25篇
物理学   78篇
  2023年   1篇
  2022年   1篇
  2020年   1篇
  2016年   7篇
  2015年   4篇
  2014年   16篇
  2013年   11篇
  2012年   4篇
  2011年   4篇
  2010年   2篇
  2009年   4篇
  2008年   5篇
  2007年   6篇
  2005年   4篇
  2004年   7篇
  2003年   4篇
  2002年   4篇
  2001年   4篇
  2000年   2篇
  1999年   1篇
  1997年   6篇
  1996年   1篇
  1993年   4篇
排序方式: 共有103条查询结果,搜索用时 15 毫秒
21.
Since the work of Mejdahl in the mid-1980s feldspars have been used widely for palaeodosimetry. They have proved particularly popular because of the technical ease with which an optically stimulated luminescence signal can be obtained, and the potential for their use in dating over a wider time range than quartz. However, while the use of infrared stimulated lminescence has been a great success, the realisation of the potential for dating over a wide time range has been hampered by a series of behavioural problems, in particular concerned with the stability of the luminescence signal. This paper surveys the current state of knowledge of a range of aspects of the stimulated luminescence behaviour of feldspar. Particular attention is paid to the thermal and optical properties of the thermoluminescence (TL) and optically stimulated luminescence (OSL) signals from feldspars since these are of greatest relevance to their use as palaeodosimeters. Results obtained from well-characterised museum specimens demonstrate the variety of responses that are seen from different types of feldspar, particularly in their TL behaviour. Less variation is seen in their OSL response. In contrast, the response of potassium-rich feldspars separated from Quaternary sediments tends to be very consistent when many grains are analysed simultaneously, suggesting that averaging of the signal simplifies the behaviour of the system.  相似文献   
22.
The paper reviews basic spectral features of luminescence from minerals used in dating and allied research. Luminescence production is a result of multiple interactions within the imperfect crystal lattice and spectral information is not limited to the emission of light. Results of spectral investigations of luminescence emission during thermal stimulation (TL) or optical stimulation (OSL) form the main part of the paper. However, information on luminescence excitation and light absorption spectroscopy is also presented and possible links between luminescence production in minerals and particular lattice defects are considered. Quartz and feldspars, the most commonly used minerals, receive special attention, but the review includes other materials such as polymineral fine-grained fractions from sediments, zircon, calcite and other salts (halite, sulfate), meteorites, flint, volcanic materials (obsidian, tephra), ceramics and metallurgical slags. Although a wide range of different luminescence emission wavebands occur, it can be shown that certain emissions dominate in particular materials. Basic dosimetric properties are often known just for single emission wavebands of a particular mineral, and are listed in this case. The paper also aims to provide a starting point and inspiration for the study of other TL and OSL emissions, with particular regard to their potential and suitability for dating and related dosimetry tasks. These investigations, involving palaeodose determination based on an emission waveband with known characteristics, need careful separation of the particular emission peak, which may be influenced by its behaviour during the dating procedure (sample preparation, irradiation, preheat treatments, luminescence measurements, etc.). Spectral information available in this context and some technical remarks on the experimental conditions will be given to pave the way for conventional TL or OSL measurements in luminescence dating and dosimetry using natural or semi-natural materials.  相似文献   
23.
《Comptes Rendus Physique》2013,14(5):412-417
In this paper, we introduce a study that we carried out in order to validate the use of a simplified pregnant woman model for the assessment of the fetus exposure to radio frequency waves. This simplified model, based on the use of a homogeneous tissue to replace most of the inner organs of the virtual mother, would allow us to deal with many issues that are raised because of the lack of pregnant woman models for numerical dosimetry. Using specific absorption rate comparisons, we show that this model could be used to estimate the fetus exposure to plane waves.  相似文献   
24.
A very extensive study of the radiation field at aircraft altitudes has been carried out over the last few years. These investigations formed part of a European wide collaboration involving several laboratories with extensive experience in cosmic ray research and/or dosimetry. Among the main topics investigated were the charge spectra, LET spectra, anisotropy and dose values. The measurements were performed on subsonic and supersonic flights covering a wide range of altitudes and latitudes. Several active and passive instruments were employed in these studies and some results obtained with nuclear track detectors are described here. Comparisons are made with the results of other experiments and theoretical estimates using computer codes.  相似文献   
25.
A personal imaging plate (IP) dosimeter is in the process of being developed for neutron fields using the BaFBr:Eu2+ phosphor. A configuration incorporating a polyethylene radiator placed before the IP detector is used to produce protons via (n,p) elastic scattering. For a dosimeter sensitive to thermal neutrons, a Nylon plate ( thick) is placed between the polyethylene (1.2 mm thick) radiator and the IP ( thick sensitive layer) detector to produce protons via the 14N(n,p)14C reaction. Dosimeters having these configurations have been exposed to neutrons from 241Am–Be and 252Cf sources at the Institute for Radioprotection and Nuclear Safety of Cadarache at angles of 0 (normal incidence), 30 and 60 and several dose equivalents. The personal dose equivalent response in terms of Hp(10) is evaluated from the net measured photostimulated luminescence densities (). The calibration factor obtained for estimating the personal dose equivalent with this dosimeter is for 241Am–Be and for 252Cf.  相似文献   
26.
Fission track dating has greatly expanded its usefulness to geology over the last 40 years. It is central to thermochronology—the use of shortened fission tracks to decipher the thermal history, movement, and provenance of rocks. When combined with other indicators, such as zircon color and (U–Th)/He, a range of temperatures from C to C can be studied. Combining fission track analysis with cosmogenic nuclide decay rates, one can study landscape development and denudation of passive margins. Technological applications have expanded from biological filters, radon mapping, and dosimetry to the use of ion track microtechnology in microlithography, micromachining by ion track etching, microscopic field emission tips, magnetic nanowires as magnetoresistive sensors, microfluidic devices, physiology of ion channels in single cells, and so on. In nuclear and particle physics, relatively insensitive glass detectors have been almost single-handedly responsible for our knowledge of cluster radioactivity, and plastic track detectors together with automated measuring systems have been used at the Bevalac, Brookhaven, CERN, and GSI, mainly to study fragmentation of high-energy heavy nuclei. Almost everything we know about the ultraheavy cosmic rays has been learned using Lexan on the Long Duration Exposure Facility and BP-1 phosphate glass on the Mir Station. New topics include development of calorimetric aerogels capable of measuring kinetic energies of hypervelocity interstellar and interplanetary dust grains in space and research on identification of strains of Bacillus spores by measurements of their size and swelling rates when humidified.  相似文献   
27.
Hydrodynamic cavitation (HC) has been extensively investigated for effluent treatment applications. Performance of HC devices or processes is often reported in terms of degradation of organic pollutants rather than quantification of hydroxyl (OH) radicals. In this study, generation of OH radicals in vortex based cavitation device using coumarin dosimetry was quantified. Coumarin was used as the chemical probe with an initial concentration of 100 µM (15 ppm). Generation of OH radicals was quantified by analysing generated single hydroxylated products. The influence of operating parameters such as pH and type of acid used to adjust pH, dissolved oxygen, and inlet and outlet pressures was investigated. Acidic pH was found to be more conducive for generating OH radicals and therefore subsequent experiments were performed at pH of 3. Sulphuric acid was found to be more than three times effective than hydrochloric acid in generating OH radicals. Effect of initial levels of dissolved oxygen was found to influence OH radical generation. Performance of vortex based cavitation device was then compared with other commonly used cavitation devices based on orifice and venturi. The vortex based cavitation device was found to outperform the orifice and venturi based devices in terms of initial per-pass factor. Influence of device scale (nominal flow rate through the device) on performance was then evaluated. The results presented for these devices unambiguously quantifies their cavitational performance. The presented results will be useful for evaluating computational models and stimulate further development of predictive computational models in this challenging area.  相似文献   
28.
Current radiation dosimetry methods involve the release of trapped charge carriers in the form of electrons-holes pairs generated by irradiation exposure of the dosimetric materials. Thermal and optical stimulations of the irradiated material freed the trapped charges that eventually recombine with interband centers producing the emission of light. The integrated intensity of the emitted light is proportional to the radiation dose exposure. In this work, we present an UV radiation dosimetry technique based on the characteristic persistence luminescence (PLUM) 4f65d1→4f7 electronic transition of Eu2+ ions in SrAl2O4:Eu2+, Dy3+. The dose assessment is carried out by measuring the PLUM signal integrated during a certain time. The PLUM performance of SrAl2O4:Eu2+, Dy3+ phosphor exhibited a linear behavior for the first 50 s of UV irradiation. For higher UV time exposure the behavior is sublinear with no apparent saturation during a 10 min period. The PLUM dosimetry response was performed at 400 nm that corresponds to the main band component of the PLUM excitation spectrum in the 250-500 nm range. The main advantage of a dosimeter device based on the PLUM of SrAl2O4:Eu2+, Dy3+ is that neither thermal nor optical stimulation is required, avoiding the need of cumbersome electronic photo/thermal stimulation equipment. Due to the highly efficient 250-500 nm PLUM response of SrAl2O4:Eu2+, Dy3+, it could have potential application as UV radiation dosimeter in the UV range of grate human health concerns caused by UV solar radiation.  相似文献   
29.
This study concentrated on assessment of the basic physical properties of a polymer gel dosimeter evaluated by NMR. For this, BANG-2 type polymer gel was prepared. The dosimeters were irradiated by 60Co gamma photons and by 4, 6 and 18 MV X-ray photons for doses in the range 0–50 Gy. The multi-echo CPMG sequence was used for the evaluation of T2-relaxation times in the irradiated gel dosimeters. Dependence of 1/T2 in terms of the following factors was studied: absorbed dose, energy of applied radiation, temperature during NMR evaluation, time between irradiation and NMR evaluation and strength of the magnetic field. An exponential dependence of the 1/T2 response on absorbed dose in the range 0–50 Gy was observed, while in the range 0–10 Gy the data could be fitted by a linear function. This paper also describes the dependence of 1/T2 response on: radiation energy, strength of magnetic field and time from irradiation of the dosimeters to NMR evaluation. Increase of gel dosimeter 1/T2 response with the decrease of the temperature during NMR evaluation has been qantitatively described. The polymer gel dosimetry system used in this study proved that it is a reliable system for three-dimensional dose distribution measurement.  相似文献   
30.
The luminescence properties of gemstones (silicates, carbonates, phosphates, etc.), are of interest since could be potentially employed as personal dosimeters not only in case of radiation accident or radiological terrorism where conventional monitoring was not established, but also as a UV personal dosimeter. We, herein, report on preliminary results of the UV-induced 480 nm-thermoluminescence (TL) response of a well-characterised natural albite (NaAlSi3O8) from Minas Gerais (Brazil) that, due to its high transparency, is used as gemstone. Different annealing on several aliquots (from 480 to 960 °C) induces several changes in the sensitivity of the sample probably associated with (i) dehydration and dehydroxylation processes and (ii) changes in the lattice structure increasing the Al/Si disorder giving rise to ionic self-diffusion of alkali atoms, thermal stress into atomic positions and variation in the concentration of alkali ions in planar defects. The complex structure of albite has several planar defects (twinning and exsolution interphases which contain hydroxyl groups, water molecules, etc.) that can act as luminescence centres. When the thermal preannealed samples are exposed to 1 h at 254.7 nm under lab conditions one can appreciate changes in the TL behaviour that allows us to think in the albite as a potential UV dosimeter. ©2006 Elsevier Ltd. All rights reserved.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号