排序方式: 共有171条查询结果,搜索用时 15 毫秒
41.
Manipulating bacteria and understanding their behavior when interacting with different substrates are of fundamental importance for patterning, detection, and any other topics related to health-care, food-enterprise, etc. Here, we adopt an innovative dielectrophoretic (DEP) approach based on electrode-free DEP for investigating smart but simple strategies for immobilization and orientation of bacteria. Escherichia coli DH5-alpha strain has been selected as subject of the study. The light induced DEP is achieved through ferroelectric iron-doped lithium niobate crystals used as substrates. Due to the photorefractive (PR) property of such material, suitable light patterns allow writing spatial-charges-distribution inside its volume and the resultant electric fields are able to immobilize E. coli on the surface. The experiments showed that, after laser irradiation, about 80% of bacteria is blocked and oriented along a particular direction on the crystals within an area of few square centimeters. The investigation presented here could open the way for detection or patterning applications based on a new driving mechanism. Future perspectives also include the possibility to actively switch by light the DEP forces, through the writing/erasing characteristic of PR fields, to dynamically control biofilm spatial structure and arrangement. 相似文献
42.
Dielectrophoresis is a versatile tool for the sorting, immobilization, and characterization of cells in microfluidic systems. The performance of dielectrophoretic systems strongly relies on the configuration of microelectrodes, which produce a nonuniform electric field. However, once fabricated, the microelectrodes cannot be reconfigured to change the characteristics of the system. Here, we show that the reorientation of the microfluidic channel with respect to the microelectrodes can be readily utilized to alter the characteristics of the system. This enables us to change the location and density of immobilized viable cells across the channel, release viable cells along customized numbers of streams within the channel, change the deflection pattern of nonviable cells along the channel, and improve the sorting of viable and nonviable cells in terms of flow throughput and efficiency of the system. We demonstrate that the reorientation of the microfluidic channel is an effective tool to create versatile dielectrophoretic platforms using the same microelectrode design. 相似文献
43.
This paper provides an overview on separation of micron and submicron sized biological (cells, yeast, virus, bacteria, etc.) and nonbiological particles (latex, polystyrene, CNTs, metals, etc.) by dielectrophoresis (DEP), which finds wide applications in the field of medical and environmental science. Mathematical models to predict the electric field, flow profile, and concentration profiles of the particles under the influence of DEP force have also been covered in this review. In addition, advancements made primarily in the last decade, in the area of electrode design (shape and arrangement), new materials for electrode (carbon, silicon, polymers), and geometry of the microdevice, for efficient DEP separation of particles have been highlighted. 相似文献
44.
Youlan Li 《Analytica chimica acta》2004,507(1):151-161
This paper presents the development and experimental verification of a DEP fluidic system capable of fractionation of intact biological cells in suspension into purer subpopulations. This was accomplished by employing a specially shaped nonuniform electric field, synthesized by microfabricated planar microelectrode arrays, housed on an insulating glass substrate. To improve the efficiency of cell sorting, the microelectrodes are individually biased by a variable frequency alternating current (ac) voltage source, which allows us to exploit both positive and negative dielectrophoresis (DEP) to affect cell separation. Furthermore, through suitable establishment of a cell stream supported by sheath flow, such fractionation is achieved in a continuous fashion. The proposed DEP fluidic fractionation may be configured to operate in three (3) different modes. In this work, however, a detailed account is only presented for one mode of operation. The simulation of the electric field and force profiles, together with the experimental results obtained on model cells (plant protoplasts), confirm our theoretical predictions and furthermore demonstrate improvements in both separation efficiency and throughput over a wide range of frequencies (10 Hz to 5 kHz). 相似文献
45.
Model‐based analysis of a dielectrophoretic microfluidic device for field‐flow fractionation
下载免费PDF全文
![点击此处可从《Journal of separation science》网站下载免费的PDF全文](/ch/ext_images/free.gif)
Bobby Mathew Anas Alazzam Mohammad Abutayeh Ion Stiharu 《Journal of separation science》2016,39(15):3028-3036
We present the development of a dynamic model for predicting the trajectory of microparticles in microfluidic devices, employing dielectrophoresis, for Hyperlayer field‐flow fractionation. The electrode configuration is such that multiple finite‐sized electrodes are located on the top and bottom walls of the microchannel; the electrodes on the walls are aligned with each other. The electric potential inside the microchannel is described using the Laplace equation while the microparticles' trajectory is described using equations based on Newton's second law. All equations are solved using finite difference method. The equations of motion account for forces including inertia, buoyancy, drag, gravity, virtual mass, and dielectrophoresis. The model is used for parametric study; the geometric parameters analyzed include microparticle radius, microchannel depth, and electrode/spacing lengths while volumetric flow rate and actuation voltage are the two operating parameters considered in the study. The trajectory of microparticles is composed of transient and steady state phases; the trajectory is influenced by all parameters. Microparticle radius and volumetric flow rate, above the threshold, do not influence the steady state levitation height; microparticle levitation is not possible below the threshold of the volumetric flow rate. Microchannel depth, electrode/spacing lengths, and actuation voltage influence the steady‐state levitation height. 相似文献
46.
Eva‐Maria Laux Xenia Knigge Frank F. Bier Christian Wenger Ralph Hlzel 《Electrophoresis》2015,36(17):2094-2101
The combination of alternating electric fields with nanometer‐sized electrodes allows the permanent immobilization of proteins by dielectrophoretic force. Here, atomic force microscopy is introduced as a quantification method, and results are compared with fluorescence microscopy. Experimental parameters, for example the applied voltage and duration of field application, are varied systematically, and the influence on the amount of immobilized proteins is investigated. A linear correlation to the duration of field application was found by atomic force microscopy, and both microscopical methods yield a square dependence of the amount of immobilized proteins on the applied voltage. While fluorescence microscopy allows real‐time imaging, atomic force microscopy reveals immobilized proteins obscured in fluorescence images due to low S/N. Furthermore, the higher spatial resolution of the atomic force microscope enables the visualization of the protein distribution on single nanoelectrodes. The electric field distribution is calculated and compared to experimental results with very good agreement to atomic force microscopy measurements. 相似文献
47.
48.
In this article, we propose a novel dielectrophoretic continuous flow sorter using planar micro electrodes coupled to a channel constriction. This design enables a high particle sorting efficiency at low voltages while relying on a simple fabrication and integration process. We have numerically simulated the AC electrokinetic effects and the fluid behavior to predict particle trajectories. Simulation results are in accordance with experimental data: 10 and 5 μm polystyrene beads were continuously sorted with <2% errors at flow speeds of 100 μm/s. We were also able to change the particle buffer while sorting beads. Finally, to demonstrate the interest of our device for cell sorting, we also sorted dead and living yeast cells according to their different dielectric properties. Living cell concentration was enriched by a factor of 4 versus dead cell concentration after passing the sorting device. 相似文献
49.
We describe the development and testing of a setup that allows for DEP field‐flow fractionation (DEP‐FFF) of irreversibly electroporated, reversibly electroporated, and nonelectroporated cells based on their different polarizabilities. We first optimized the channel and electrode dimensions, flow rate, and electric field parameters for efficient DEP‐FFF separation of moderately heat‐treated CHO cells (50°C for 15 min) from untreated ones, with the former used as a uniform and stable model of electroporated cells. We then used CHO cells exposed to electric field pulses with amplitudes from 1200 to 2800 V/cm, yielding six groups containing various fractions of nonporated, reversibly porated, and irreversibly porated cells, testing their fractionation in the chamber. DEP‐FFF at 65 kHz resulted in distinctive flow rates for nonporated and each of the porated cell groups. At lower frequencies, the efficiency of fractionation deteriorated, while at higher frequencies the separation of individual elution profiles was further improved, but at the cost of cell flow rate slowdown in all the cell groups, implying undesired transition from negative into positive DEP, where the cells are pulled toward the electrodes. Our results demonstrate that fractionation of irreversibly electroporated, reversibly electroporated, and nonelectroporated cells is feasible at a properly selected frequency. 相似文献
50.
AA Kayani K Khoshmanesh TG Nguyen G Kostovski AF Chrimes M Nasabi DA Heller A Mitchell K Kalantar-zadeh 《Electrophoresis》2012,33(14):2075-2085
The emergence of optofluidics has brought a high degree of tuneability and reconfigurability to optical devices. These possibilities are provided by characteristics of fluids including mobility, wide range of index modulation, and abrupt interfaces that can be easily reshaped. In this work, we created a new class of optofluidic waveguides, in which suspended mesoparticles were employed to greatly enhance the flexibility of the system. We demonstrated tuneable quasi single mode waveguides using spatially controllable mesoparticles in optofluidics. The coupling of waveguiding modes into the assembly of mesoparticles produces strong interactions and resonant conditions, which promote the transitions of the waveguiding modes. The modal response of the system depends on the distribution of packed particles above the polymeric rib waveguide which can be readily controlled under the appropriate combination of dielectrophoresis and hydrodynamic forces. 相似文献