排序方式: 共有38条查询结果,搜索用时 15 毫秒
31.
Constantinos Kousoulos 《Talanta》2007,72(2):360-367
A high-throughput LC-MS/MS method was developed for the simultaneous determination of Risperidone and 9-OH-risperidone in human plasma. A semi-automated sample preparation procedure was applied, including protein precipitation after addition of ACN, via a robotic system, and subsequent sub-zero temperature extraction of the latter. Injections of the ACN extractants were performed on a turbulent flow ternary column-switching system, consisted of dual extraction columns in parallel for on-line purification of samples and an analytical column. Toggling with the assistance of two valves provided a run cycle time of 3 min and the whole procedure minimized carry-over effect. On-line clean-up procedure along with sub-zero temperature extraction increased sample purification and extended column life. The analytical range of the method was 0.1-200 ng mL−1 for both analytes with excellent linearity and very good accuracy and precision. The proposed method was employed in a bioequivalence study after per os administration of a 2 mg tablet of risperidone and allowed the completion of the study (>1400 samples) in only 4 days time. 相似文献
32.
Katrin M. Kirschbaum Susann Finger Friederike Vogel Rainer Burger Manfred Gerlach Peter Riederer Christoph Hiemke 《Chromatographia》2008,67(3-4):321-324
An automated high performance liquid chromatography with column-switching and ultraviolet detection was developed for the
analysis of risperidone and 9-hydroxyrisperidone. The method needs minimum sample preparation and is useful for the detection
down to a limit of 1 ng mL−1. Sample clean-up of serum was carried out on a CN 20 μm SPE-column using 8% (v/v) acetonitrile in water. Chromatographic separation was performed on ODS Hypersil C18 material with 38% (v/v) acetonitrile and 0.4% (v/v) TEMED in water. Application of the method to the analysis of serum samples confirmed its suitability for therapeutic drug
monitoring of risperidone and 9-hydroxyrisperidone. 相似文献
33.
Summary A rapid, simple, accurate and sensitive liquid chromatographic assay with on-line solid-phase extraction is described for
determination of trovafloxacin in human serum. Samples were deproteinized with acetonitrile and injected on to an NH2 extraction column for sample clean-up. Thereafter, an on-line column-switching system was used for quantitative transfer
of the drug to a C18 analytical column. Separation was performed by ion-pair chromatography and detection was by ultraviolet absorbance at 275
nm. Recovery was 98.5%. The linear range was from 0.25 to 20μg mL−1, with a correlation coefficient of 0.999. Detection limit was 0.1 μg mL−1 from extraction of 25 μL serum. 相似文献
34.
A column-switching high-performance liquid chromatography (HPLC) method is described for the simultaneous determination of loganin and sweroside, which are the active ingredients of purified herbal extract from Lonicera japonica (SKL JI), in rat plasma using column-switching and ultraviolet (UV) absorbance detection. Plasma was simply filtrated prior to injection to the HPLC system consisting of a clean-up column, a concentrating column, and an analytical column, which were connected with two six-port switching valves. Detection of loganin and sweroside was accurate and repeatable, with a limit of quantitation of 0.05 μg ml−1 in plasma. The calibration curves for both loganin and sweroside were linear over the concentration ranges of 0.05-40.0 and 0.02-40.0 μg ml−1 in rat plasma, respectively. The intra- and inter-day precision over the concentration range for loganin and sweroside were lower than 8.1 and 10.9% (relative standard deviation, R.S.D.), and accuracy was between 94.7 and 113.5 and 95.0 and 113.1%, respectively. This method has been successfully applied to determine the levels of loganin and sweroside in rat plasma samples from pharmacokinetics studies. 相似文献
35.
A novel restricted access-molecularly imprinted material (RA-MIP) with selectivity for sulfonamides was synthesized using initiator-transfer agent-terminator (iniferter) method, a "living"/controlled radical polymerization technique. The material was prepared by grafting two layers with different functions on the silica support. To perform a "grafting from" polymerization, iniferter was immobilized on the surface of silica. The internal sulfamethazine imprinted polymer and the external poly(glycidyl methacrylate) [poly(GMA)] were then grafted successively. The hydrophilic structures were formed on the external layer of the material by the hydrolysis of the linear poly(GMA) for protein removal. The result has shown that this restricted access-MIP grafted silica (RA-MIP-SG) not only has the selectivity for the template and its analog, but also has the ability of exclusion for bovine serum albumin (BSA). It indicated that the material possesses both properties of molecularly imprinted polymer (MIP) and restricted access material (RAM). Using RA-MIP-SG as pre-column, a column-switching HPLC method was established for the determination of sulfonamides in bovine milk. Direct sample injection was performed in the analysis, which provides a convenient analytical procedure. Good linearity in the range of 2-400 ng mL(-1) (R>0.998) has been obtained for seven sulfonamides in the study. The recoveries of all the analytes at three concentration levels are between 93% and 107% with the RSD<8.0%. The limits of quantification and limits of detection are less than or equal to 2.7 ng mL(-1) and 0.8 ng mL(-1) respectively. It demonstrated this RA-MIP-SG can be applied in sample extraction and clean-up for the determination of sulfonamides in bovine milk by direct injection and column-switching HPLC with good efficiency and reliability. 相似文献
36.
Hamase K Takagi S Morikawa A Konno R Niwa A Zaitsu K 《Analytical and bioanalytical chemistry》2006,386(3):705-711
Using a column-switching HPLC system combining a micro-ODS column and a chiral column, the amounts of d-proline (d-Pro) have been determined in 18 tissues, plasma and urine of mice. To avoid the enzymatic degradation of d-amino acids in vivo, a mutant mouse strain lacking d-amino acid oxidase activity (ddY/DAO− mouse) was used. In the brain, relatively large amounts of d-Pro were observed in the anterior pituitary, posterior pituitary and pineal glands. In the peripheral tissues, the amounts
of d-Pro were high in the pancreas and kidney. Above all, it is surprising that the ddY/DAO− mice excreted large amounts of d-Pro in their urine (433 nmol/mL, 20 times that of l-Pro). The origin of d-Pro has also been investigated. By comparing germ-free mice and gnotobiotic mice, intestinal bacteria were shown to have
no effect on the urinary d-Pro amount. Concerning the dietary origin, a notable amount of d-Pro was still excreted in the urine after starvation for 4 days, suggesting that some of the d-Pro is produced in the mice. Age-dependent changes in the urinary d-Pro amount have also been investigated from the postnatal 1st month up to 12 months, and ddY/DAO− mice were found to excrete large amounts of d-Pro in the urine constantly throughout their lives.
Kenji Hamase is Associate Professor in the Department of Bioanalytical Chemistry, Graduate School of Pharmaceutical Sciences at Kyushu
University. His current research interests focus on the development of analytical methods for d-amino acids and the study of their physiological functions and diagnostic values. He received the Japanese Society for Analytical
Chemistry Award for Young Scientists in 2003, and the PSJ Award for Young Scientists in 2006. 相似文献
37.
Summary Two methods were developed for the determination of CGP 6140 and its N-oxide metabolite. The first method was based on trace
enrichment, rinsing on a first column (LiChroprep RP-2) andbackflush on the analytical column (Spherisorb ODS 1). The second method was based on trace enrichment onto a cartridge andforwardflush on the analytical column using the Advanced Automated Sample Processor (AASP). CGP 6140 and its N-oxide metabolite are spectrophotometrically
detected at 405nm. The reproducibility and accuracy of the methods were convenient. The limits of quantitation (50nmol/l in
plasma and 250 nmol/l in urine) were sufficient to follow the concentrations of CGP 6140 and its N-oxide metabolite after
a 100mg single oral dose of CGP 6140 to volunteers. 相似文献
38.
Naoki Hamada Yuki Hashi Satoshi Yamaki Yanli Guo Lin Zhang Haifang Li Jin-Ming Lin 《中国化学快报》2019,30(1):99-102
A column-switching system, composed of supercritical fluid extraction (SFE) and reverse phase liquid chromatography/mass spectrometry (RPLC/MS) was constructed for on-line extraction and reverse-phase separation of capsaicinoids in capsicum fruits. 相似文献