首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   191篇
  免费   18篇
  国内免费   1篇
化学   193篇
力学   1篇
物理学   16篇
  2023年   2篇
  2022年   12篇
  2021年   18篇
  2020年   14篇
  2019年   7篇
  2018年   4篇
  2017年   4篇
  2016年   10篇
  2015年   10篇
  2014年   8篇
  2013年   8篇
  2012年   11篇
  2011年   12篇
  2010年   13篇
  2009年   9篇
  2008年   10篇
  2007年   13篇
  2006年   11篇
  2005年   3篇
  2004年   9篇
  2003年   6篇
  2002年   1篇
  2001年   2篇
  1999年   2篇
  1997年   3篇
  1996年   2篇
  1992年   1篇
  1989年   1篇
  1988年   1篇
  1987年   2篇
  1982年   1篇
排序方式: 共有210条查询结果,搜索用时 15 毫秒
201.
202.
Ruecha N  Siangproh W  Chailapakul O 《Talanta》2011,84(5):1323-1328
In this work, the rapid detection of cholesterol using poly(dimethylsiloxane) microchip capillary electrophoresis, based on the coupling of enzymatic assays and electrochemical detection, was developed. Direct amperometric detection for poly(dimethylsiloxane) (PDMS) microchip capillary electrophoresis was successfully applied to quantify cholesterol levels. Factors influencing the performance of the method (such as the concentration and pH value of buffer electrolyte, concentration of cholesterol oxidase enzyme (ChOx), effect of solvent on the cholesterol solubility, and interferences) were carefully investigated and optimized. The migration time of hydrogen peroxide, product of the reaction, was less than 100 s when using 40 mM phosphate buffer at pH 7.0 as the running buffer, a concentration of 0.68 U/mL of the ChOx, a separation voltage of +1.6 kV, an injection time of 20 s, and a detection potential of +0.5 V. PDMS microchip capillary electrophoresis showed linearity between 38.7 μg/dL (1 μM) and 270.6 mg/dL (7 mM) for the cholesterol standard; the detection limit was determined as 38.7 ng/dL (1 nM). To demonstrate the potential of this assay, the proposed method was applied to quantify cholesterol in bovine serum. The percentages of recoveries were assessed over the range of 98.9-101.8%. The sample throughput was found to be 60 samples per hour. Therefore, PDMS microchip capillary electrophoresis, based on the coupling of enzymatic assays and electrochemical detection, is very rapid, accurate and sensitive method for the determination of cholesterol levels.  相似文献   
203.
The analytical capabilities of the microminiaturized lab-on-a-valve (LOV) module integrated into a microsequential injection (μSI) fluidic system in terms of analytical chemical performance, microfluidic handling and on-line sample processing are compared to those of the micro total analysis systems (μTAS), also termed lab-on-a-chip (LOC). This paper illustrates, via selected representative examples, the potentials of the LOV scheme vis-à-vis LOC microdevices for environmental assays. By means of user-friendly programmable flow and the exploitation of the interplay between the thermodynamics and the kinetics of the chemical reactions at will, LOV allows accommodation of reactions which, at least at the present stage, are not feasible by application of microfluidic LOC systems. Thus, in LOV one may take full advantage of kinetic discriminations schemes, where even subtle differences in reactions are utilized for analytical purposes. Furthermore, it is also feasible to handle multi-step sequential reactions of divergent kinetics; to conduct multi-parametric determinations without manifold reconfiguration by utilization of the inherent open-architecture of the micromachined unit for implementation of peripheral modules and automated handling of a variety of reagents; and most importantly, it offers itself as a versatile front end to a plethora of detection schemes. Not the least, LOV is regarded as an emerging downscaled tool to overcome the dilemma of LOC microsystems to admit real-life samples. This is nurtured via its intrinsic flexibility for accommodation of sample pre-treatment schemes aimed at the on-line manipulation of complex samples. Thus, LOV is playing a prominent role in the environmental field, whenever the monitoring of trace level concentration of pollutants is pursued, because both matrix isolation and preconcentration of target analytes is most often imperative, or in fact necessary, prior to sample presentation to the detector.  相似文献   
204.
We describe a novel, cost effective and simple technique for the manufacture of high sensitivity absorption cells for microfluidic analytical systems. The cells are made from tinted polymethyl methacrylate (PMMA) in which microfluidic channels are fabricated. Two windows (typically 250 μm thick, resulting in little optical power loss) are formed at either end of the channel through which light is coupled. Unwanted stray light from the emitter passes through a greater thickness of the tinted substrate (typically the length of the cell) and is preferentially absorbed. In effect, this creates a pin-hole configuration over the length of the absorption cell, providing improved performances (sensitivity, S/N ratios, baseline noise and limit of detection) when used as an absorption cell compared to clear substrates. The method is used to achieve a LOD of 20 nM with a colourimetric iron assay and a LOD of 0.22 milli-absorption units with a pH assay.  相似文献   
205.
The antitumor activity of certain anti-inflammatory drugs is often attributed to an indirect effect based on the inhibition of COX enzymes. In the case of anti-inflammatory prodrugs, this property could be attributed to the parent molecules with mechanism other than COX inhibition, particularly through formulations capable of slowing down their metabolic conversion. In this work, a pilot docking study aimed at comparing the interaction of two prodrugs, nabumetone (NB) and its tricyclic analog 7-methoxy-2,3-dihydro-1H-cyclopenta[b]naphthalen-1-one (MC), and their common active metabolite 6-methoxy-2-naphthylacetic acid (MNA) with the COX binding site, was carried out. Cytotoxicity, cytofluorimetry, and protein expression assays on prodrugs were also performed to assess their potential as antiproliferative agents that could help hypothesize an effective use as anticancer therapeutics. Encouraging results suggest that the studied compounds could act not only as precursors of the anti-inflammatory metabolite, but also as direct antiproliferative agents.  相似文献   
206.
A new carbazole-based Zn2+ selective fluorescent sensor L has been developed. In CH3CN/H2O (1:1, v/v, HEPES 10 mM, pH=7.4) solution, L displays selective and ratiometric responses to Zn2+ through excimer formation. The Zn2+ recognition process has good anti-interference ability over other metal ions. The dinuclear complex Zn2L2 was further used as a receptor for oxalate. Through constructing a chemosensing ensemble with chromeazurol S, colorimetric recognition of oxalate in water solution was achieved via indicator displacement assays. The oxalate recognition process exhibits obvious color changes from blue to yellow and is naked eye detectable.  相似文献   
207.
Following a recently developed concept of MS binding assays based on the quantification of a native marker by LC–MS a procedure to study binding of a low-affinity marker in kinetic, saturation, and competition experiments was established. Separation of bound and unbound marker—the most crucial step of the assay—could be effectively achieved by filtration in a 96-well-format. MS binding assays according to this procedure allowed the reliable characterization of NO 711 binding to mGAT1 in presence of physiological NaCl concentrations. Comparing the results obtained in the present study with those from experiments using 1 mol L−1 NaCl in the incubation milieu reveals remarkable differences with respect to the marker’s affinity and kinetics and to the investigated test compound’s potency. Principle of MS binding assays After incubation of a target with a native marker, bound and unbound marker are separated by filtration. Subsequently, the bound native marker is liberated from the target and finally quantified by LC-MS-MS. Dedicated to Prof. Hans-Dietrich Stachel on the occasion of his 80th birthday  相似文献   
208.
We present a novel homogeneous (“mix‐incubate‐read”) droplet microfluidic assay for specific protein detection in picoliter volumes by fluorescence polarization (FP), for the first time demonstrating the use of FP in a droplet microfluidic assay. Using an FP‐based assay we detect streptavidin concentrations as low as 500 nM and demonstrate that an FP assay allows us to distinguish droplets containing 5 μM rabbit IgG from droplets without IgG with an accuracy of 95%, levels relevant for hybridoma screening. This adds to the repertoire of droplet assay techniques a direct protein detection method which can be performed entirely inside droplets without the need for labeling of the analyte molecules.  相似文献   
209.
《Analytical letters》2012,45(2):187-201
Abstract

The synthesis of tetradeuterated 15-methyl-PGF and 17-phenyl-18, 19, 20-trinor-PGF, is described. Gas chromatographic -mass spectrometric methods, using the deuterated compounds as internal standards and carriers, for quantitation of corresponding unlabeled prostaglandin analogues is described. With acceptable accuracy and precision the sensitivity is in the subpicomole range.  相似文献   
210.
Bioactivity and chemical reactivity of bioactive glass offer the ability to bond for soft and hard biological tissues. In this work, synthesis was carried out by using melting and rapid quenching. Strontium was introduced as trace element at different contents in the glass matrix, according to its concentration in the bone matrix. This chemical element presents a high interest in the bone metabolism activity. Investigations were conducted on the surface of biomaterials by using in vitro assay after immersion in SBF. Several physico-chemical methods such as SEM, FTIR, NMR, ICP-OES and MTT test were employed to highlight the effects of the Sr. The in vitro experiments showed that after soaking in SBF, the behaviour of pure glass is different compared to glass doped with Sr. NMR analyses showed in the 29Si MAS-NMR that glass matrix undergoes some changes after in vitro assays particularly the emergence of new components attributed to Q3(OH). The presence of Sr slowed down the bioactivity of glass after immersion in SBF. The non toxic character of compounds was confirmed. Introduction of Sr at 0.1 wt % induce an enhancement of cells at about 14.3%.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号