排序方式: 共有216条查询结果,搜索用时 0 毫秒
11.
12.
M. M. Guedes da Mota M. A. Jonker B. Griepink 《Fresenius' Journal of Analytical Chemistry》1979,296(5):345-349
Summary The sample of seawater (51) is freed from solid particles, buffered at pH 5.6 and percolated through a column filled with ED3A. After sample passage 15 ml 1 M hydrochloric acid solution are pumped through the column to dissolve the concentrated ions. The final measurement using flame atomic absorption is carried out in the hydrochloric acid solution. The total labour time is less than 15 min. The standard deviations (4 analyses) for the determination of Cu, Pb and Zn (in the normal concentration range of 2–6 g · l–1) were 2–5%, 5% and 1–10%, the recoveries 100%, 102% and 104%, respectively. A concentration coefficient of 300–500 was obtained.On leave from Lisbon University, Portugal 相似文献
13.
A. Dornemann und H. Kleist 《Fresenius' Journal of Analytical Chemistry》1979,294(5):402-404
Zusammenfassung Eine selektive Bestimmung von Antimon durch Atomabsorptionsspektrometrie ist durch elektrothermale Atomisierung von Antimonwasserstoff in einem Argonspülgasstrom möglich. Das Verfahren erfordert eine hohe und reproduzierbare Geschwindigkeit der Reduktion des Antimons zu Antimonwasserstoff in der wäßrigen Probelösung. Geeignete Bedingungen für diese Reduktion erreicht man, wenn man in der Lösung zunächst einen Komplex von Antimon(III) mit Äthylendiamintetraessigsäure bildet; dieser Komplex reagiert mit Natriumborhydrid in der geforderten Weise zu Antimonwasserstoff. Bei der Mineralisierung des organischen Materials ist auf genaue Temperaturführung zu achten.
Determination of nanotraces of antimony in biological samples
Summary High selectivity in measuring antimony by atomic absorption spectrometry is obtained by electrothermal atomisation of stibine in a stream of argon purging gas. This procedure requires a fast and reproducible reduction to stibine of the total antimony present in an aequeous solution. Optimum conditions for this reduction are reached by first transforming all antimony in the solution to an EDTA-chelate of antimony(III) which then reacts uniformly with sodium boron hydride to give stibine. Close temperature control is essential in decomposition of biological samples.相似文献
14.
15.
Klaus -Richard Sperling 《Fresenius' Journal of Analytical Chemistry》1980,301(4):294-299
Summary In natural waters, heavy metals such as Cd may be present in bound form. It is, therefore, important to consider chemical speciation, especially at low concentrations of the metal where a significant part can be bound by other trace constituents so tightly that it escapes several forms of its determination. It has been demonstrated that even the very strong complexant APDC is unable to leach out all of the heavy metal present in several coastal water samples from the German Bight.This paper describes a new micro method for the determination of total Cd in natural waters. First a small sample is dried in a polypropylene vial. Then the salt residue is heated to 90° C with a mixture of sulphuric and nitric acid for digestion of organic trace constituents (and oxidation of sulphides if present). After dilution subsamples are neutralized using an excess of NaHCO3 buffer solution. Extraction results are then independent from the possible slight variations of pH. The extractant, a solution of APDC in CCl4 is stable for weeks, and even the extract is stable for at least 16h. Precision is in the range of 7% at a concentration of 0.066 g Cd l–1; the detection limit is below 0.002 g l–1 and can be lowered, if necessary, by enlargement of the original sample. According to the sensitivity of the method the typical blank of 0.022 g Cd l–1 is high, but it is rather constant (mean variation from the mean: 0.0024 g l–1).Teil XI: Fresenius Z. Anal. Chem. 299, 206–207 (1979) 相似文献
16.
M. D. Sastry M. K. Bhide K. Savitri Y. Babu B. D. Joshi 《Fresenius' Journal of Analytical Chemistry》1979,298(5):367-372
Summary Studies were conducted on the assay of Sm, Eu, Dy and Er separated from uranium using aqueous standards by electrothermal AAS with Massmann type graphite furnace. The working curves were found to be linear in the ranges Sm (1–10 g/ml), Eu (0.05–0.6 g/ml), Dy (0.1–0.8 g/ml) and Er (0.1–1.0 g/ml). The values obtained for synthetic samples agreed favourably with those obtained by emission spectrographic method. Experiments using pyrolytic carbon coated tubes with and without pretreatment by La, Ta and Y have shown an enhancement with treatment upto a maximum of 15% and improve the memory effect marginally. The effect of Ta treatment was found to be singularly useful in improving the general behaviour of Sm. The interference effects of lanthanides, other than the analyte, were found to be negligible. However, the presence of uranium was found to affect the absorbance. The absorbance of Eu was found to be nearly independent of uranium after an initial increase. On the other hand, the absorbance of other elements studied was found to drastically decrease after an initial enhancement. Detailed investigations of temperature dependence of absorbance were carried out using Eu, Dy and Er. The differences in the behaviour of these elements is attributed to probable differences in the modes of their atomization.
Untersuchung von aus Uran abgetrenntem Samarium, Europium, Dysprosium und Erbium durch elektrothermische Atomabsorptions-Spektralphotometrie
Zusammenfassung Die Untersuchungen wurden mit Hilfe des Graphitrohrofens nach Maßmann durchgeführt. In folgenden Bereichen ergaben sich lineare Eichkurven: Sm 1–10 g/ml, Eu 0,05–0,6 g/ml, Dy 0,1–0,8 g/ml, Er 0,1-1,0 g/ml. Die aus synthetischen Proben erhaltenen Ergebnisse stimmten gut mit den durch Emissionsspektrographie erhaltenen überein. Versuche wurden mit Röhren mit pyrolytischen Kohlenstoffüberzug mit und ohne Vorbehandlung durch La, Ta und Y durchgeführt und ergaben eine bis 15%ige Steigerung durch die Behandlung sowie eine mäßige Besserung des Memoryeffektes. Eine Behandlung mit Ta war besonders für Sm vorteilhaft. Störungen durch andere Lanthanide waren vernachlässigbar. Uran beeinflußte jedoch die Absorption. Im Falle von Eu zeigte sich nach anfänglicher Zunahme fast eine Unabhängigkeit, während bei den anderen untersuchten Elementen nach anfänglicher Zunahme eine beträchtliche Abnahme auftrat. Mit Eu, Dy und Er wurde ebenfalls die Temperaturabhängigkeit der Absorption untersucht. Festgestellte Unterschiede im Verhalten werden auf unterschiedliche Atomisierung zurückgeführt.相似文献
17.
Summary Two methods of instrumental neutron activation analysis for the determination of selenium in steels, based on respectively77mSe (t
1/2
= 17.5 s) and75Se (t
1/2 = 120 d) are presented. Good agreement is obtained by application of both methods on a series of steels containing selenium at the 0.1% level. Interferences and advantages associated with either method are discussed.
Bestimmung von Selen in Stahl durch Neutronenaktivierung und Ge(Li)--Spektrometrie
Zusammenfassung Zwei Methoden werden beschrieben, die auf der Messung von77mSe (t 1/2 = 17,5 s) bzw.75Se (t 1/2 = 120 d) beruhen. Bei der Anwendung auf Stähle mit Selengehalten in der Größenordnung von 0,1 % wurden gut übereinstimmende Werte erhalten. Störungen und Vorteile der Methoden werden diskutiert.相似文献
18.
R. D. Parker 《Fresenius' Journal of Analytical Chemistry》1978,292(5):362-364
Summary An extraction technique is described for the determination of ppm concentrations of both hydrophobic and hydrophilic methylsiloxane compounds in water, based on a single extraction with a mixed solvent of (11) l-pentanol and methyl isobutyl ketone followed by the determination of the silicone compounds extracted into the mixed solvent by atomic absorption spectroscopy. The method is applicable over the concentration range 0.3–30 ppm Si. Standard deviation in the case of 10 ppm Si is 0.313.
Bestimmung von siliciumorganischen Verbindungen in Wasser mit Hilfe der Atomabsorptions-Spektralphotometrie
Zusammenfassung Zur Bestimmung von ppm-Konzentrationen an hydrophoben und hydrophilen Methylsiloxanverbindungen im Wasser wird ein Extraktionsverfahren beschrieben. Hierbei wird nach einfacher Extraktion mit l-Pentanol/Methylisobutylketon (11) das Silicium im Extrakt mit Hilfe der AAS bestimmt. Der erfaßbare Konzentrationsbereich liegt bei 0,3–30 ppm Si. Die Standardabweichung beträgt bei 10 ppm Si 0,313.相似文献
19.
20.