首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   32篇
  免费   0篇
化学   13篇
力学   4篇
数学   3篇
物理学   11篇
综合类   1篇
  2020年   1篇
  2019年   1篇
  2013年   1篇
  2011年   3篇
  2010年   3篇
  2009年   5篇
  2008年   3篇
  2007年   1篇
  2005年   1篇
  2004年   2篇
  2003年   1篇
  2002年   1篇
  1997年   1篇
  1993年   2篇
  1992年   2篇
  1991年   1篇
  1987年   1篇
  1985年   1篇
  1978年   1篇
排序方式: 共有32条查询结果,搜索用时 15 毫秒
11.
12.
Automated, high-resolution, quantitative, high-throughput analysis of mono- and oligosaccharides, produced by enzymatic digestion of cellohexaose (model substrate) and lignocellulosic biomass, is demonstrated using high-performance capillary electrophoresis in conjunction with a single-step fluorophore labeling strategy for sensitive laser-induced fluorescence detection. Unattended batch sample processing from 96-well plates enabled reliable industrial-scale carbohydrate analysis. Excellent resolution of mono- and oligosaccharides was achieved under suppressed electroosmotic flow conditions, using either covalently or dynamically coated fused-silica capillary columns. The proposed approach readily supports the demands of bioindustrial operation environments with respect to high-throughput carbohydrate profiling.  相似文献   
13.
14.
在一系列H模放电条件下,建立了一个旨在研究等离子体温度分布剖面不变性的数据库。介绍了数据库建立过程中要解决的关键问题和所用软件,对等离子体温度分布剖面不变性及芯部约束与边缘参数的关系进行了研究。  相似文献   
15.
Several aspects of the Barkhausen effect can be investigated by using a measurement equipment that records the Barkhausen signal as a function of time in digital form on computer tape. Measurements on thin magnetic films containing a small number of domain walls are presented. The behaviour of the wall jumps during a reversal is investigated. During the steep part of the loop the stationarity of the signal is measured with the magnetic field as a parameter. The influence of the coercive fieldH c and the thicknessd m is considered and compared with results obtained by others on bulk samples.  相似文献   
16.
Molina L  Messina GA  Stege PW  Salinas E  Raba J 《Talanta》2008,76(5):1077-1082
This study report an human serum IgG antibodies to Helicobacter pylori quantitation procedure based on the multiple use of an immobilized H. pylori antigen on an immuno-column incorporated into an a flow-injection (FI) analytical system. The immuno-adsorbent column was prepared by packing 3-aminopropyl-modified controlled-pore glass (APCPG) covalently linking H. pylori antigens in a 3-cm of Teflon tubing (0.5 i.d.). Antibodies in the serum sample are allowed to react immunologically with the immobilized H. pylori antigen, and the bound antibodies are quantified by alkaline phosphatase (AP) enzyme-labeled second antibodies specific to human IgG. p-Aminophenyl phosphate (pAPP) was converted to p-aminophenol (pAP) by AP and an electroactive product was quantified on glassy carbon electrode (GCE) modified with multiwall carbon nanotubes (MWCNT) (GCE-CNTs) at 0.30 V. The total assay time was 25 min. The calculated detection limits for amperometric detection and the ELISA procedure are 0.62 and 1.8 UmL(-1), respectively. Reproducibility assays were made using repetitive standards of H. pylori-specific antibody and the intra- and inter-assay coefficients of variation were below 5%. The immuno-affinity method showed higher sensitivity and lower time-consumed, demonstrate its potential usefulness for early assessment of human serum immunoglobulin G (IgG) antibodies to H. pylori.  相似文献   
17.
A quasielastic neutron scattering study of Ni2Mo6S8 has established relatively fast long-range motion of the intercalated Ni2+ ions, with a diffusion constantD=3×10–9 cm2 s–1. A model with a jump distance of about 2.1 Å and an activation energy of 24 kJ/mol is favoured. A critical consideration of the information contained in fixed window measurements is given.  相似文献   
18.
We discuss the separation and determination of cadmium and copper in plant samples such as Triticum durum (wheat) and Helianthus annuus (sunflower) using open tubular capillary electrochromatography with indirect detection. Before performing the analysis, the samples were digested by microwave‐assisted methods using HNO3. Regarding the electrophoretic system, several experimental parameters were previously evaluated such as the capillary surface, mobile phase composition, buffer, pH, and voltage applied. The baseline resolution of the studied metals was obtained within 8 min by using a capillary immobilized with carboxylic multi‐walled carbon nanotubes and a background electrolyte composed of 6 mM imidazole, pH 4.0. The applied voltage and the temperature were set at 20 kV and 25°C, respectively. Precision, detection, and quantification limits, along with linearity were investigated. The limits of detection and quantification were 2.20 and 7.40 μg/kg, for Cu2? and 0.05 and 0.20 μg/kg in the case of Cd2?. A good linearity was achieved over a concentration working range of 7.5–100 and 0.2–25 μg/kg for Cu2? and Cd2? accordingly. Recovery data for validation studies were found in a range of 98.2–101.5% for both analytes.  相似文献   
19.
Automated 96-capillary array electrophoresis (CAE) methodology described in the first part of the present work offered large-scale high-performance profiling of oligo- and monosaccharides to fulfill the needs of bioindustrial laboratories. Sensitivity at low nanomolar concentration, good resolving power and reliability achieved in the experiments is invaluable for monitoring reaction products from enzymatic polysaccharide digestion with numerous applications in agricultural, chemical and food industries. In addition to optimization of mono- and oligosaccharide separations in CAE system and necessary operational protocol modifications, capillary-to-capillary and run-to-run variation in migration time and signal intensity necessitated development of data normalization tools. Internal fluorescent standards have been incorporated into the analysis aiding migration time normalization and CAE trace alignment. Data processing, visualization, and programming tools have been developed along with quantification approaches.  相似文献   
20.
This paper addresses the use of different slotted pores in rotating membrane emulsification technology.Pores of square and rectangular shapes were studied to understand the effect of aspect ratio (1-3.5) and their orientation on oil droplet formation.Increasing the membrane rotation speed decreased the droplet size,and the oil droplets produced were more uniform using slotted pores as compared to circular geometry.At a given rotation speed,the droplet size was mainly determined by the pore size and the fluid velocity of oil through the pore (pore fluid velocity).The ratio of droplet diameter to the equivalent diameter of the slotted pore increased with the pore fluid velocity.At a given pore fluid velocity and rotation speed,pore orientation significantly influences the droplet formation rate: horizontally disposed pores (with their longer side perpendicular to the membrane axis) generate droplets at double the rate of vertically disposed pores.This work indicates practical benefits in the use of slotted membranes over conventional methods.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号