排序方式: 共有25条查询结果,搜索用时 31 毫秒
11.
We present the theoretical investigation of spontaneous magnetization of a coupled 2×2 πring array. It is indicated by free energy calculation that the system has the lowest energy when the four π rings have the full antiparallel configuration. Furthermore, the numerical evaluation results show that the system which favours full antiparallel spontaneous magnetization is a quantum effect deriving from the phase cohering of the superconducting quantum wavefunctions in the four superconducting rings through the shared Josephson junctions. 相似文献
12.
A new high-T_c (HT_c) rf SQUID working at around 1.3GHz has been developed to avoid electromagnetic interference such as growing mobile communication jamming. This new system works in a frequency range from 1.23 to 1.42GHz (centred at 1.3GHz), which is not occupied by commercial communication. The sensor used in the 1.3GHz rf SQUID is made of a HT_c coplanar superconducting resonator and a large-area HT_c superconducting film concentrator. We have achieved in the 1.3GHz HT_c rf SQUID system a minimal flux noise of 2.5×10^{-5}Φ_0/\sqrt{Hz} and a magnetic field sensitivity of 38fT/\sqrt{Hz} in white noise range, respectively. The effective area of the concentrator fabricated on a 15×15mm^2 substrate is 1.35mm^2. It is shown that the 1.3GHz rf SQUID system has a high field sensitivity. Design and implementation of 1.3GHz HT_c rf SQUID offers a promising direction of rf SQUID development for higher working frequency ranges. 相似文献
13.
The electromagnetic field of a human heart system is a bioelectromagnetic field. Electrocardiography (ECG) and magnetocardiography (MCG) are both carriers of electromagnetic information about the cardiac system, and they are nonstationary signals. In this study, ECG and MCG data from healthy subjects are acquired; the MCG data are captured using a high-Tc radio frequency superconducting quantum interference device (HTc rf SQUIDs) and the QRS complexes in these data are analysed by the evolutionary spectrum analysis method. The results show that the quality factor Q and the central frequency fz of the QRS complex evolutionary spectrum are the characteristic parameters (CHPs) of ECG and MCG in the time-frequency domain. The confidence intervals of the mean values of the CHPs are estimated by the Student t distribution method in mathematical statistics. We believe that there are threshold ranges of the mean values of Q and fz for healthy subjects. We have postulated the following criterion: if the mean values of CHPs are in the proper ranges, the cardiac system is in a normal condition and it possesses the capability of homeostasis. In contrast, if the mean values of the CHPs do not lie in the proper ranges, the homeostasis of the cardiac system is lacking and some cardiac disease may follow. The results and procedure of MCG CHPs in the study afford a technological route for the application of HTc rf SQUIDs in cardiology. 相似文献
14.
15.
A new high-T_c (HT_c) rf SQUID working at around 1.3GHz has been developed to avoid electromagnetic interference such as growing mobile communication jamming. This new system works in a frequency range from 1.23 to 1.42GHz (centred at 1.3GHz), which is not occupied by commercial communication. The sensor used in the 1.3GHz rf SQUID is made of a HT_c coplanar superconducting resonator and a large-area HT_c superconducting film concentrator. We have achieved in the 1.3GHz HT_c rf SQUID system a minimal flux noise of 2.5×10^{-5}Φ_0/\sqrt{Hz} and a magnetic field sensitivity of 38fT/\sqrt{Hz} in white noise range, respectively. The effective area of the concentrator fabricated on a 15×15mm^2 substrate is 1.35mm^2. It is shown that the 1.3GHz rf SQUID system has a high field sensitivity. Design and implementation of 1.3GHz HT_c rf SQUID offers a promising direction of rf SQUID development for higher working frequency ranges. 相似文献
16.
17.
任何事物的内部都存在着矛盾,而矛盾的双方在一定条件下可以相互转化.在不等式的解集中,解集的端点值来自相应方程的解和定义域.下面举例说明不等式与方程之间的这种辩证关系在解客观题中的应用. 相似文献
18.
19.
The electromagnetic field of a human heart system is a bioelectromagnetic field. Electrocardiography (ECG) and magnetocardiography (MCG) are both carriers of electromagnetic information about the cardiac system,and they are nonstationary signals. In this study,ECG and MCG data from healthy subjects are acquired; the MCG data are captured using a high-T c radio frequency superconducting quantum interference device (HTc rf SQUIDs) and the QRS complexes in these data are analysed by the evolutionary spectrum analysis method. The results show that the quality factor Q and the central frequency f z of the QRS complex evolutionary spectrum are the characteristic parameters (CHPs) of ECG and MCG in the time-frequency domain. The confidence intervals of the mean values of the CHPs are estimated by the Student t distribution method in mathematical statistics. We believe that there are threshold ranges of the mean values of Q and f z for healthy subjects. We have postulated the following criterion: if the mean values of CHPs are in the proper ranges,the cardiac system is in a normal condition and it possesses the capability of homeostasis. In contrast,if the mean values of the CHPs do not lie in the proper ranges,the homeostasis of the cardiac system is lacking and some cardiac disease may follow. The results and procedure of MCG CHPs in the study afford a technological route for the application of HTc rf SQUIDs in cardiology. 相似文献
20.
原子饱和吸收谱谐波稳频短期稳定度研究 总被引:2,自引:0,他引:2
介绍了利用腔外饱和吸收谱的三次谐波和五次谐波稳频方法对半导体激光器进行稳频的原理,分析了使用这两种稳频方法对半导体激光器进行稳频时所得到的激光频率短期稳定度的理论估算方法,提出了通过选取最佳调制深度来优化短期稳定度的方法和原理,并在理论上比较了两种稳频方法得到的短期稳定度的差异。然后讨论了半导体激光稳频电路系统的设计,并利用该电路系统,分别用三次谐波和五次谐波稳频的方法将半导体激光器的频率锁定在的^87Rb饱和吸收的F=2→F′=3,1线上,并使用我们提出的短期稳定度优化方案进行稳定度优化,通过对误差信号的分析,估算出的频率稳定度达到10^-12的量级,使用采集到的误差信号在实验上比较了两种稳频方法所得的稳定度的,其结果和理论基本吻合。 相似文献