排序方式:
出版年(降序)
出版年(升序)
被引次数(降序)
被引次数(升序)
更新时间(降序)
更新时间(升序)
杂志中文名(升序)
杂志中文名(降序)
杂志英文名(升序)
杂志英文名(降序)
作者中文名(升序)
作者中文名(降序)
作者英文名(升序)
作者英文名(降序)
相关性
共有10000条查询结果,搜索用时 9 毫秒
3.
An organocatalytic asymmetric chlorinative dearomatization of naphthols was realized for the first time, providing chiral naphthalenones with a Cl-containing all-substituted stereocenter in excellent yields and enantioselectivity (up to 97% yield and 96% ee). The reaction features mild reaction conditions, good tolerance of diverse functional groups and simple reaction operation.
相似文献
5.
评价Actigraph GT3X三轴加速度传感器测量中国男性人群典型体力互动信效度,开发基于中国人群步行活动模式的GT3X三轴加速度传感器能耗推算方程。方法受试对象包括青年组(21.92±1.14岁),老年组(55.5±4.52岁)。受试者佩戴GT3X三轴加速度传感器,在跑台上分别完成3km/h(慢走)、4.5km/h(正常步行)、4.5km/h10%(上坡步行)、6km/h(快走)以及7.5km/h(慢跑)速度的走跑运动各5min。受试者佩戴COSMED K4b2便携式代谢测试仪,并将GT3X三轴加速度传感器佩戴于髋部,同步采集心肺功能仪及加速度传感器数据。结果根据受试对象4种无坡度走跑运动推导出线性方程MET=0.000653*counts(Axis1)+2.345521以及线性方程MET=0.000689*counts(VM)+1.640721,但其相关系数不高;GT3X+三轴加速度传感器记录上坡步行(4.5km/h10%)运动与无坡度运动(4.5km/h)相比,三轴counts及VM均显示有差异性(P<0.05),但counts增加率远低于MET增加率;GT3X+三轴加速度传感器两次重复测试,pearson值高,即离散程度低。结论本研究推导垂直轴(Axis1)、三轴矢量和(VM)的线性方程,为中度相关,误差值较大,且上坡运动时的GT3X+三轴加速度传感器记录counts值与MET值呈非线性相关,提示Actigraph GT3X三轴加速度传感器能耗推算方程可根据不同运动方式、运动强度推算相对应方程;Actigraph GT3X三轴加速度传感器测量我国成年及老年男性人群步行活动其信度较高。
相似文献
6.
首次对刺纹车轮虫(TrichodinacentrostrigataBasson,VanAs & Paperna, 1983)进行了 18S rDNA 的克隆测序并分析,研究结果显示:刺纹车轮虫是一种具有辐射状中央颗粒的淡水车轮虫,具有相对较高的 GC 含量而位于分子系统树的顶枝,它与海水环境中的车轮虫具有较高的序列相似性及较近的遗传距离从而聚为一枝。研究提示刺纹车轮虫具有较强的宿主适应性,在系统进化中分化较晚并与海水种类具有较近的亲缘关系;此外,车轮虫的同源性与 18S rDNA序列相似性、遗传距离具明显相关性,GC 含量与分子支序树分枝具有明显相关性。
相似文献
7.
聚山梨酯80又名吐温80,为一种亲水型非离子表面活性剂,是食品、保健品和药品中常用的辅料,作为增溶剂和澄清剂广泛用于中药注射剂。近年来,不良反应的发生使得聚山梨酯80的质量和应用愈加受到重视,有研究认为其加入可能引起注射剂不良反应增加。为避免超量使用,有必要对该辅料的投料加以严格控制。中药注射剂中聚山梨酯80的含量测定是当下研究的热点和难点,可以通过分光光度法、分子排阻-蒸发光散射检测法(SEC-ELSD)、液质联用法(LC-MS)直接测定,也可以水解后法经液相色谱-紫外检测法(HPLC-UV)或气相色谱法(GC)间接测定。但由于聚山梨酯80为聚氧乙烯聚合数目不同的混合物、不同厂家生产的聚山梨酯80化学组分及比例存在较大差异,难以采用统一的转换公式或对照品准确定量。此外,中药注射剂的复杂基质造成的假阳性干扰也对定量提出了挑战。为解决以上问题,以生脉注射液为例,提出基于吸收系数的中药注射剂中聚山梨酯80含量测定新方法。优化检测波长、显色剂种类、液液萃取过程振荡和静置时间,在6个不同品牌仪器上测得聚山梨酯80-硫氰酸钴配合物的吸收系数(
E 1%
1 cm )为104.23,相对标准偏差(RSD)为2.08%。生脉注射液稀释10倍后,精密量取供试品溶液1.0 mL,精密加入硫氰酸钴溶液10 mL,二氯甲烷20 mL,涡旋振荡3 min。将混合液移至分液漏斗中,静置30 min,取下层二氯甲烷液,将前1 mL弃去,接收约15 mL,在320 nm处测定吸光度,再根据Lambert-Beer定律,利用获得的吸收系数计算得到聚山梨酯80的含量。方法阴性无干扰,精密度和重复性相对标准偏差均低于3%,平均回收率为98.42%。为进一步验证方法的准确性,分别采用吸收系数法和标准曲线法测定了2个厂家的10批生脉注射液,并与实际投料量比较。配对
t 检验结果表明,当置信度为95%时,两种方法无显著性差异,吸收系数法测得结果与企业生产中聚山梨酯的实际投料量也无显著性差异。研究采用前人未采用的、灵敏度更高的320 nm为检测波长,显著降低了基质干扰,克服了中药注射剂中聚山梨酯80测定结果与实际投料量难以吻合的问题。吸收系数法无需使用对照品,亦不用制备标准曲线,可为中药注射剂中聚山梨酯80的检查标准提供切实可行的解决方案。所建方法灵敏、准确、快速、简便,为含聚山梨酯80制剂的质量控制提供了关键常数及新的思路。
相似文献
8.
Zhenju antihypertensive compound (ZJAHC) is a combined Chinese–Western medicine formula including clonidine (CLO), hydrochlorothiazide (HCT), rutin,
Chrysanthemum indicum extract and pearl powder. Compared with CLO preparations, ZJAHC shows improved activities and decreased adverse effects. It is believed that the side effects of CLO are caused by its high peak plasma concentration. Hence, study of the influence of ZJAHC on the pharmacokinetic behaviors of clonidine seems essential. In present study, the plasma concentrations of CLO were determined with a liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method. The MS/MS transitions monitored for clonidine and internal standard were 230.2 → 213.1 and 152.2 → 110.2, respectively. The analyte was quantified in a single run within 3 min. The pharmacokinetic study showed that the area under the plasma concentration–time curve of CLO in ZJAHC (60 µg/kg CLO) was similar to that of CLO‐HCT‐high (120 µg/kg CLO) but the peak concentration was much lower than that in CLO‐HCT‐high. ZJAHC could enhance the bioavailability without greatly increasing peak concentration of clonidine. This comprehensive effect of enhancing the bioavailability and avoiding the high peak plasma concentration for CLO might mainly result from the co‐contribution of Western medicine and traditional Chinese medicine (TCM), while the effect of TCM was stronger than that of Western medicine. Copyright © 2014 John Wiley & Sons, Ltd.
相似文献
9.
To establish a new method of testing and evaluating the quality of refined montan wax (RMW), digital color and GC fingerprint technology were introduced and applied. CIE Lab color mode was used to digitize the exterior colors of RMW, and the score obtained through a fitting function was also used to reflect its quality. It is shown that they were in complete accord with the human visual perception trend. The GC fingerprint was used to characterize the internal chemical information of RMW, and the composition of its internal features was reflected through the relative retention time (RRT) and relative peak area (RPA) values. It is shown that there was a high degree of similarity between the fingerprints, while certain differences also existed. This can be used to implement effective application of RMW to aspects such as quality control, adulteration identification, and origin attributions.
相似文献
10.
系统研究了PbF2+GeO2+WO3ⅩⅣTmF3玻璃陶瓷材料中,在近红外光(1.06μm)激发下,Tm3+离子的发光特性.实验中观测到Tm3+离子的两组峰值位置分别在20920cm-1和22173cm-1的蓝色上转换发光,并证实这两组上转换发光分别与吸收三个和四个光子有关,同时建立了上转换发光的模型.为了选择最佳掺杂浓度,详细地测量了Tm3+离子峰值为20920cm-1的蓝色上转换发光强度与TmF3浓度的关系.
相似文献