Components of co-continuous phase can form an interpenetrating network structure, which has great potential to synergistically improve the mechanical properties of the blends, and to impart the functional blends superior electrical conductivity and permeability. In this work, the effects of shear rates (50–5000 s?1) at different temperatures on the phase morphology, phase size and lamellar crystallites of biodegradable co-continuous polybutylene terephthalate (PBAT)/polybutylene succinate (PBS) blend are quantitatively investigated. The results show that the above features of the PBAT/PBS have a strong dependence on the shear flow and thermal field. The co-continuous phase of the blend is well maintained at 130 °C. Interestingly, this phase structure transforms into a “sea-island” structure at 160 °C, which gradually recovers to a co-continuous phase when the shear rate increases from 1000 s?1 to 5000 s?1. The phase size decreases with the increase of shear rate both at 130 °C and 160 °C due to the refinement and deformation of phase structures caused by strong shear stress. Unexpectedly, a unique phenomenon is observed that the shear-induced lamellar crystallites are oriented perpendicular to shear direction in the range of 500–5000 s?1 at 130 °C, while the orientation of lamellar crystallites at 160 °C is along the shear direction within the whole range of shear rates. The degree of orientation for the PBAT/PBS blend crystals increases first and then decreases at both temperatures above. In addition, the range of shear rate has reached the level in the industrial processing. Therefore, this work has important guiding significance for the regulation of the co-continuous phase structure and the performance for the blend in the practical processing.
Herein, we investigated the analytical features of potentiometric immunosensors for detection of alpha-fetoprotein (AFP) in hepatocellular carcinoma at different electrodes, such as carbon fiber microelectrode (CFME) and carbon-disk electrode (CDE), respectively. To construct such an immunosensor, anti-AFP capture antibodies were first conjugated covalently onto the activated electrodes through typical carbodiimide coupling. Thereafter, one-step immunoreaction protocol was successfully introduced to develop a new potentiometric immunoassay upon addition of AFP. Accompanying the antigen-antibody reaction, the surface charges of the modified electrodes were changed for the readout of electric potential. Results indicated that the linear range of CDE-based immunosensor was 0.1–100 ng mL−1 AFP, whereas the assay sensitivity by using CFME could be further increased to 3.2 pg mL−1 with the linear range from 0.01 to 500 ng mL−1 AFP. Meanwhile, CFME-based immunosensor showed high sensitivity, good reproducibility and specificity, and could be utilized for the analysis of human serum specimens with consistent results relative to commercialized ELISA kit. 相似文献