首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   847篇
  免费   1篇
化学   504篇
晶体学   1篇
力学   2篇
数学   9篇
物理学   39篇
无线电   293篇
  2016年   22篇
  2015年   23篇
  2014年   53篇
  2013年   33篇
  2012年   130篇
  2011年   92篇
  2010年   94篇
  2009年   89篇
  2008年   81篇
  2007年   47篇
  2006年   49篇
  2005年   51篇
  2004年   39篇
  2003年   41篇
  2002年   2篇
  1998年   1篇
  1997年   1篇
排序方式: 共有848条查询结果,搜索用时 15 毫秒
81.
82.
We are just beginning to exploit the fascinating potential of thionine, called electrochemical probe that can selectively recognize specific polycyclic aromatic hydrocarbons (PAHs), as tools for the detection of tricyclic aromatic hydrocarbons phenanthrene (PHE) and anthracene (ANT). A novel electrochemical sensing platform by modification of electroactive thionine functionalized graphene onto glass carbon electrode (Th/GRs/GCE) surface was constructed. The immobilized thionine showed a remarkable stability, which may benefit from the π–π stacking force with graphene. Under optimum conditions, the proposed electrochemical sensor exhibited high sensitivity and low detection limit for detecting PHE and ANT. The total amount of PHE and ANT could be quantified in a wide range of 10 pM–0.1 μM with a good linearity (R2 = 0.9979) and a low detection limit of 0.1 pM (S/N = 3). Compounds which possess one or two benzene rings or PAHs with more than three rings, such as benzene, naphthalene (NAP), benzo[a]pyrene (BaP) and pyrene (PYR) show little interference on the detection. Consequently, a simple and sensitive electrochemical method was proposed for the determination of PHE and ANT, which was used to determine PHE and ANT in waste water samples. The electrochemical method provides a general tool that complements the commonly used spectroscopic methods and immune method for the detection of PAHs.  相似文献   
83.
Mass spectrometry (MS) techniques are commonly used for protein identification and further analysis of selected protein spots after high resolution 2-D electrophoresis. Complementary gel-free approaches have been developed during the last few years and have shown to be useful tools in modern proteomics. The development and application of various gel-free electrophoresis devices for performing protein fractionation according to the pI differences is therefore a topic of interest. This review describes the current state of isoelectric focusing (IEF) gel-free electrophoresis based on the Agilent offgel 3100 fractionator. The review includes, therefore, (i) an overview on IEF as well as other previous IEF gel-free electrophoresis developments; (ii) offgel fundamentals and future trends; (iii) advantages and disadvantages of current offgel procedures; (iv) requirements of isolated protein pellets for further offgel fractionation; (v) offgel fraction requirements to perform the second dimensional analysis by advance electrophoresis and chromatographic techniques; and (vi) effect of the offgel operating conditions on the stability of metal–protein complexes.  相似文献   
84.
85.
86.
87.
88.
Motivated by potential benefits such as sensor miniaturization, multiplexing opportunities and higher sensitivities, refractometric nanoplasmonic biosensing has profiled itself in a short time span as an interesting alternative to conventional Surface Plasmon Resonance (SPR) biosensors. This latter conventional sensing concept has been subjected during the last decades to strong commercialization, thereby strongly leaning on well-developed thin-film surface chemistry protocols. Not surprisingly, the examples found in literature based on this sensing concept are generally characterized by extensive analytical studies of relevant clinical and diagnostic problems. In contrast, the more novel Localized Surface Plasmon Resonance (LSPR) alternative finds itself in a much earlier, and especially, more fundamental stage of development. Driven by new fabrication methodologies to create nanostructured substrates, published work typically focuses on the novelty of the presented material, its optical properties and its use – generally limited to a proof-of-concept – as a label-free biosensing scheme. Given the different stages of development both SPR and LSPR sensors find themselves in, it becomes apparent that providing a comparative analysis of both concepts is not a trivial task. Nevertheless, in this review we make an effort to provide an overview that illustrates the progress booked in both fields during the last five years. First, we discuss the most relevant advances in SPR biosensing, including interesting analytical applications, together with different strategies that assure improvements in performance, throughput and/or integration. Subsequently, the remaining part of this work focuses on the use of nanoplasmonic sensors for real label-free biosensing applications. First, we discuss the motivation that serves as a driving force behind this research topic, together with a brief summary that comprises the main fabrication methodologies used in this field. Next, the sensing performance of LSPR sensors is examined by analyzing different parameters that can be invoked in order to quantitatively assess their overall sensing performance. Two aspects are highlighted that turn out to be especially important when trying to maximize their sensing performance, being (1) the targeted functionalization of the electromagnetic hotspots of the nanostructures, and (2) overcoming inherent negative influence that stem from the presence of a high refractive index substrate that supports the nanostructures. Next, although few in numbers, an overview is given of the most exhaustive and diagnostically relevant LSPR sensing assays that have been recently reported in literature, followed by examples that exploit inherent LSPR characteristics in order to create highly integrated and high-throughput optical biosensors. Finally, we discuss a series of considerations that, in our opinion, should be addressed in order to bring the realization of a stand-alone LSPR biosensor with competitive levels of sensitivity, robustness and integration (when compared to a conventional SPR sensor) much closer to reality.  相似文献   
89.
In the last decades, the solid-waste management related to the extensively growing production of plastic materials, in concert with their durability, have stimulated increasing interest in biodegradable polymers. At present, a variety of biodegradable polymers has already been introduced onto the market and can now be competitive with non biodegradable thermoplastics in different fields (packaging, biomedical, textile, etc.). However, a significant economical effort is still directed in tailoring structural properties in order to further broaden the range of applications without impairing biodegradation. Improving the performance of biodegradable materials requires a good characterization of both physico-chemical and mechanical parameters. Polymer analysis can involve many different features including detailed characterization of chemical structures and compositions as well as average molecular mass determination. It is of outstanding importance in troubleshooting of a polymer manufacturing process and for quality control, especially in biomedical applications. This review describes recent trends in the structural characterization of biodegradable materials by modern mass spectrometry (MS). It provides an overview of the analytical tools used to evaluate their degradation. Several successful applications of MALDI-TOF MS (matrix assisted laser desorption ionization time of flight) and ESI MS (electrospray mass spectrometry) for the determination of the structural architecture of biodegradable macromolecules, including their topology, composition, chemical structure of the end groups have been reported. However, MS methodologies have been recently applied to evaluate the biodegradation of polymeric materials. ESI MS represents the most useful technique for characterizing water-soluble polymers possessing different end group structures, with the advantage of being easily interfaced with solution-based separation techniques such as high-performance liquid chromatography (HPLC).  相似文献   
90.
This tutorial proposes a comprehensive and rational measurement strategy that provides specific guidance for the application of asymmetric-flow field flow fractionation (A4F) to the size-dependent separation and characterization of nanoscale particles (NPs) dispersed in aqueous media. A range of fractionation conditions are considered, and challenging applications, including industrially relevant materials (e.g., metal NPs, asymmetric NPs), are utilized in order to validate and illustrate this approach. We demonstrate that optimization is material dependent and that polystyrene NPs, widely used as a reference standard for retention calibration in A4F, in fact represent a class of materials with unique selectivity, recovery and optimal conditions for fractionation; thus use of these standards to calibrate retention for other materials must be validated a posteriori. We discuss the use and relevance of different detection modalities that can potentially yield multi-dimensional and complementary information on NP systems. We illustrate the fractionation of atomically precise nanoclusters, which are the lower limit of the nanoscale regime. Conversely, we address the upper size limit for normal mode elution in A4F. The protocol for A4F fractionation, including the methods described in the present work is proposed as a standardized strategy to realize interlaboratory comparability and to facilitate the selection and validation of material-specific measurement parameters and conditions. It is intended for both novice and advanced users of this measurement technology.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号