Dual-frequency laser interferometer has the advantagesof wide measuring scope, high speed, and high preci-sion. It is widely applied to the precision and super-precision length measuring, especially used in locatingof wafer stage in high precision step and scan lithog-raphy, which is un-substitutable. Though the technol-ogy of dual-frequency laser interferometer was developedand achieved to a relatively mature level, it is still fo-cused because of the exigent requirements in the ad-vanced man… 相似文献
27.
A real-time measurement method for the retardation of an eighth-wave plate is proposed. The collimated laser beam is split using a Glan Taylor polarizer with two side escape windows. The reflected sub-beam is detected using a detector, whereas the transmitted sub-beam passes through the quarter-wave plate and the eighth-wave plate of interest. Then, it is reflected by the mirror and passes reversely through the eighth-and quarter-wave plates. Finally, it is analyzed using the Glan Taylor polarizer and detected using another detector. With two detection signals, the retardation is resolved and found to be independent of the fast-axis direction, initial intensity, and circuit parameters. In the experiment, a crystal quartz sample is measured at different fast-axis angles. The standard deviation of the retardation is 0.9 o . The usefulness of the method is verified. 相似文献
28.
基于色氨酸本征荧光测量的生物气溶胶检测技术研究 总被引:1,自引:0,他引:1
生物气溶胶与环境质量和人类健康密切相关。基于光学测量的气溶胶检测技术具有快速、无损和灵敏的优点,是目前的研究主流。而对检测系统的标定技术及其评价方法尚无国家标准可依。基于本征荧光测量技术,研制完成了一套针对包括病毒气溶胶在内的生物气溶胶检测装置。并在此基础上,以色氨酸气溶胶作为被检物,提出了一种生物气溶胶检测与标定方法。实验结果表明,研制的检测装置对色氨酸气溶胶具良好的线性响应特性,线性相关系数R2≥0.99,灵敏度达到4000L-1。证明了通过测量气溶胶中色氨酸含量检测生物气溶胶技术的可行性与可靠性。还探讨了利用多通道本征荧光检测技术实现对生物粒子种类进行预判别的可行性。 相似文献
29.
针对微反射镜阵列(MMA)微反射镜集中度高、尺寸小,在实际检测过程中相邻镜面反射光容易出现串扰的问题,提出了一种用于微反射镜阵列角位置检测的光斑串扰抑制算法。对照射到阵列中待测微反射镜及邻域微反射镜上的光强进行标定,通过求解光强矩阵方程获得每个微反射镜的角位置信息。仿真结果显示,在检测光斑尺寸大于单个微反射镜尺寸的串扰情况下,该方法的检测精度可保持10μrad以上,满足光刻机使用指标需求。所提出的检测方法可有效解决MMA检测过程中的串扰问题,对光刻机自由光瞳照明模块的角位置检测具有重要意义。 相似文献