排序方式: 共有52条查询结果,搜索用时 0 毫秒
41.
42.
43.
报道了掺Zn的重电子金属CeCu6-xZnx(x=0.05,0.1,0.15,0.2,0.3)样品的非常规制备方法以及低温电阻和低温比热容的测量结果,研究Zn含量对CeCu6-xZnx低温性质的影响及其物理原因.发现低温下Kondo散射项系数c随Zn含量的加大而减小,电阻极大值温度Tmax随Zn含量的加大而降低,CeCu6-xZnx的德拜温度ΘD随Zn含量的加大而略有上升
关键词:
重费密子系统
低温比热容
低温电阻
相干散射 相似文献
44.
使用太阳辐射计在2021年3月至5月于丽江高原的观测数据为辐射计进行Langley定标,针对观测期间大气环境波动带来的拟合误差,提出了一种拟合前数据筛选的定标方法,通过排除掉观测期间波动幅度过大的数据,提高参与定标的数据可靠性,从而提升定标结果的精度与稳定度。结果显示经过数据筛选的Langley拟合线性度有明显提升,定标值离散程度大幅减小,各通道定标值分布区间平均减小了704,标准差减小了654,对于已得到的多日定标结果,采用拟合平均法使各波段定标值标准差减小了287~676,结果与仪器出厂定标值相对误差小于3,证明方法是可行有效的。 相似文献
45.
Hyper-spectral imaging spectrometer has high spatial and spectral resolution. Its radiometric calibration needs the knowledge of the sources used with high spectral resolution. In order to satisfy the requirement of source, an on-orbit radiometric calibration method is designed in this paper. This chain is based on the spectral inversion accuracy of the calibration light source. We compile the genetic algorithm progress which is used to optimize the channel design of the transfer radiometer and consider the degradation of the halogen lamp, thus realizing the high accuracy inversion of spectral curve in the whole working time. The experimental results show the average root mean squared error is 0.396%, the maximum root mean squared error is 0.448%, and the relative errors at all wavelengths are within 1% in the spectral range from 500 nm to 900 nm during 100 h operating time. The design lays a foundation for the high accuracy calibration of imaging spectrometer. 相似文献
46.
47.
48.
Calibration chain design based on integrating sphere transfer radiometer for SI-traceable on-orbit spectral radiometric calibration and its uncertainty analysis 下载免费PDF全文
In order to satisfy the requirement of SI-traceable on-orbit absolute radiation calibration transfer with high accuracy for satellite remote sensors,a transfer chain consisting of a fiber coupling monochromator(FBM) and an integrating sphere transfer radiometer(ISTR) was designed in this paper.Depending on the Sun,this chain based on detectors provides precise spectral radiometric calibration and measurement to spectrometers in the reflective solar band(RSB) covering 300–2500 nm with a spectral bandwidth of 0.5–6 nm.It shortens the traditional chain based on lamp source and reduces the calibration uncertainty from 5% to 0.5% by using the cryogenic radiometer in space as a radiometric benchmark and trap detectors as secondary standard.This paper also gives a detailed uncertainty budget with reasonable distribution of each impact factor,including the weak spectral signal measurement with uncertainty of 0.28%.According to the peculiar design and comprehensive uncertainty analysis,it illustrates that the spectral radiance measurement uncertainty of the ISTR system can reach to 0.48%.The result satisfies the requirements of SI-traceable on-orbit calibration and has wider significance for expanding the application of the remote sensing data with high-quality. 相似文献
49.
50.
我们对Y1-xPrxBa2Cu3O7(x=0.2,0.45,0.6)样品的比热进行了研究,发现在这个系统中比热线性项系数非常大,呈现出重费米子的特征,并且不同温区其数值亦不同.比热的结果表明Pr离子在这个系统中基本上处于+3价.对实验数据进行了仔细分析,我们认为比热线性项增大是源于Pr离子掺入后这个系统中出现了Kondo效应以及由此而产生的空穴局域态,也正是局域态的出现,导致了金属绝缘体转变,同时导致了超导电性的破坏. 相似文献