排序方式: 共有102条查询结果,搜索用时 14 毫秒
1.
2.
Ji QC Zhang J Rodila R Watson P El-Shourbagy T 《Rapid communications in mass spectrometry : RCM》2004,18(19):2293-2298
Quantitative determination of drug concentrations in tissue samples can provide critical information for drug metabolism, kinetics, and toxicity evaluations. For analysis of tissue samples using liquid chromatography/tandem mass spectrometric (LC/MS/MS) detection, homogenization is a critical step in achieving good assay performance. Assay performance can be closely evaluated by spiking the drug directly into tissue samples prior to homogenization. It is especially important to include this assay evaluation for the analysis of artery tissue samples because artery tissue is very elastic, making it quite a challenge to develop an effective procedure for homogenization. An LC/MS/MS assay in 96-well format using liquid-liquid extraction was developed for analyzing ABT-578 in rabbit artery samples. Tissue quality control samples were prepared by spiking ABT-578 stock solutions directly into the tissue before homogenization. The usage of the tissue control samples gives a thorough evaluation of the sample preparation process that includes both homogenization and sample extraction. A 20% blood in saline solution was used as a homogenization solution. Calibration standards were made by spiking ABT-578 into rabbit whole blood. Blood quality control samples were also prepared by spiking ABT-578 into rabbit whole blood. These blood QC samples were used to confirm the validity of the calibration curve. A lower limit of quantitation of 0.050 ng/mL was achieved. The linear dynamic range of blood standards was from 0.050-30.3 ng/mL with the correlation coefficient (r) ranging from 0.9969-0.9996. Overall %CV was between 1.3 and 7.0%, and analytical recovery was between 98.2 and 105.8% for blood QC samples. The %CVs for tissue QC samples were between 6.7 and 13.0%, and analytical recovery after correction was between 93.5 and 114.3%. 相似文献
3.
[reaction: see text] A molecular shuttle containing an alpha-CD macrocycle, an azobenzene unit, and two different fluorescent naphthalimide units was synthesized. The cis-trans photoisomerization of the azobenzene unit resulted in the motion of the CD macrocycle on the track. Because of the easy regulation and full reversibility of the fluorescence change of the two stopper units, the molecular shuttle could be used as a molecular storage medium or switch with all-optical inputs and outputs. 相似文献
4.
In the previous study, the proteomes of the human hepatoma cell line BEL-7404 and the normal human liver cell line L-02 were separated by high resolution two-dimensional electrophoresis (2-DE). Image analysis revealed that 99 protein spots showed quantitative and qualitative variations that were significant (P < 0.01) and reproducible. Here we report the identification results of some of these protein spots. Protein spots excised from 2-D gels were subjected to in-gel digestion with trypsin, and the resulting peptides were measured by microbore high performance liquid chromatography - ion trap - mass spectrometry (LC-IT-MS) to obtain the tandem mass (MS/MS) spectra. Twelve protein spots were identified with high confidence using SEQUEST with uninterpreted MS/MS raw data. Besides inosine-5'-monophosphate dehydrogenase 2, heat shock 27 kDa protein, calreticulin and calmodulin, whose expression was elevated in hepatoma cells, glutathione-S-transferase P was identified from hepatoma cells in which its level was 18-fold higher compared to human liver cells. Two spots were identified as the homologs of reticulocalbin for the first time in hepatoma cells and their expression increased compared to liver cells. However, tubulin beta-1 chain and natural killer cell enhancing factor B were downregulated in hepatoma cells. A tumor suppressing serpin, maspin precursor, was identified from one spot whose quantity was much higher in the normal liver cell line. More interestingly, epidermal fatty acid-binding protein (E-FABP) and fatty acid-binding protein, adipocyte-type (A-FABP), were detected in liver cells but not in hepatoma cells. The functional implication of the identified proteins was discussed. 相似文献
5.
6.
7.
8.
9.
A novel electrophoretic method for sensitive determination of nine aldehydes, including formaldehyde (C1), acetaldehyde (C2), propanal (C3), butanal (C4), pentanal (C5), hexanal (C6), glutaradehyde (Gla), 2,3-butanedione (Bud) and methylgloxal (MGo) in food samples, has been developed based on CE with amperometric detection (CE-AD). After being derivatized with an electroactive compound, 2-thiobarbituric acid (TBA), these nine non-electroactive aldehydes were converted to electroactive adducts, and therefore detectable by CE-AD approach. Experimental conditions of derivatization and CE-AD detection were optimized. The proposed method was validated according to International Conference on Harmonization (ICH) requirements, with recovery results ranging from 82.8 to 123.8%. Calibration plots of aliphatic aldehydes were linear (r2 ≥ 0.9901) in the concentration range from 0.083 to 15.0 mg/L. The LODs were between 0.008 and 0.074 mg/L. The proposed CE-AD method provides a reliable and sensitive quantitative evaluation for non-electroactive low-molecular-mass monoaldehydes and dialdehydes in real sample matrices by employing relatively simple and inexpensive instrument. 相似文献
10.
Dried blood spot (DBS) technology is an emerging alternative for sample collection in bioanalysis. Dilution for DBS samples is a challenge due to its solid sample format. Currently, DBS samples requiring dilution were first extracted as regular samples and then diluted with extracted blank samples containing internal standard (IS). Since the dilution step is a volume-critical step, extra care has to be taken to achieve accurate dilution when dealing with limited volume extracted samples. Here, we introduce an alternative sample dilution for liquid chromatography/tandem mass spectrometry (LC/MS/MS) assays using IS to track the dilution step. Dilution factor-adjusted IS working solution was first added to the sample requiring dilution before sample processing; subsequently, the processed sample was approximately diluted into the assay linear response range before LC/MS/MS analysis. We define this approach as "IS-tracked dilution". The advantage of this approach is that the diluting step is tracked by the IS and is no longer a volume-critical step. Another recognized challenge related to sample dilution is automatic sample dilution using a liquid handler. This "IS-tracked dilution" may also help address some of the challenges for automatic sample dilution of liquid samples. This new dilution approach was proven to be effective and convenient in both plasma assays and DBS assays using omeprazole as a probe compound. 相似文献