A new approach has been developed and tested for the urgent analysis of dioxins in samples of air-dust filters originating from catastrophe emissions. The procedure consists of a fast extraction of the sample with microwave solvent extraction (MASE) and acetone as solvent followed by a fast cleanup of the extract with normal phase coupled column liquid chromatography (LC/LC).
The multi-dimensional LC/LC system employs a 50 mm×4.6 mm i.d. column packed with 3 μm silica and a 150 mm×4.6 mm i.d. column packed with 5 μm PYE as the first and second analytical column, respectively. Iso-hexane is used on both columns to perform cleanup and dichloromethane to perform efficient back-flush elution of the compounds from the second column. The obtained polarity-based separation in the first dimension and molecular-structure based separation in the second dimension provides a fast and powerful cleanup.
Validation was done by analysing samples of homemade RIVM air-dust with aged residues (n=8, spiking level about 15 pg mg−1 per compound) of dioxins/furans and samples of reference Urban Dust SRM 1649a (n=4) with both the new approach and the existing conventional procedure and were instrumentally analyzed with capillary gas chromatography and high resolution mass spectrometric detection (GC/HRMS).
In comparison to the existing conventional procedure, the new approach reduces sample processing from several days to several hours per sample.
As regards the aged-residue air-dust samples, the new method shows a good accuracy, precision and high selectivity providing a performance in good agreement with the existing procedure. In SRM air-dust, the concentration of a few compounds obtained by the new method was below (10–50%) the certified value. 相似文献
Insulin-like growth factors 1 and 2 were purified from porcine plasma. In addition to the determination of their isoelectric points, the primary structures of both proteins were determined, using low microgram quantities of protein, by the versatile combination of time-of-flight plasma desorption mass spectrometry and automated Edman degradation. Porcine insulin-like growth factor 1 was shown to be homologous to both human and bovine proteins; the type 2 growth factor showed one mutation to both human and bovine type 2 proteins. 相似文献
We optimized a capillary zone electrophoretic method for separation of six angiotensin-II-receptor antagonists (ARA-IIs): candesartan, eprosartan, irbesartan, losartan potassium, telmisartan, and valsartan. A three-level, full-factorial design was applied to study the effect of the pH and molarity of the running buffer on separation. Combination of the studied parameters permitted the separation of the six ARA-IIs, which was best carried out using 60 mM sodium phosphate buffer (pH 2.5). The same system can also be applied for the quantitative determination of these compounds, but only for the more soluble ones. Some parameters (linearity, precision and accuracy) were validated. 相似文献
CIDNP has been studied during thermal decomposition, photolysis, and sensitized photolysis of benzoyl chloroacetyl peroxide. The ratio of the CIDNP intensities for the recombination products benzyl chloride and chloromethyl benzoate is dependent on the mode of decomposition, reflecting the extent of rapid decarboxylation of the primary formed benzoyloxy radicals. 相似文献
The digital filter described provides optimal enhancement of the signal-to-noise ratio by using prior information about peak shape and type of noise. The filter, based onthe matched-filter principle, is applied to chromatographic data, but is also suitable for optimal processing of similar noisy signals. The current implementation of the filter permits the specific reduction of different types of noise. Several theoretical aspects concerning the interpretation and use of this advanced filter are discussed. Some calculations on peaks with Gaussian and Gamma distribution shape are given. 相似文献
In the present work, we performed a preclinical inter-comparison study using several photosensitizers with the goal of optimizing photodynamic therapy (PDT) for the treatment of choroidal neovascularization (CNV) associated with age-related macular degeneration. The tested molecules were the porphyrins meso-tetraphenylporphyrin (TPP) and meso-tetra-(4-carboxyphenyl)-porphyrin (TCPP), and the chlorins pheophorbide-a (Pheo-a) and chlorin e(6) (Ce(6)). Each of these molecules was entrapped in biodegradable nanoparticles (NP) based on poly(d,l-lactic acid). The influence of the degree of lipophilicity on the incorporation efficiency of the drug in the NPs, and on the dye leakage from blood vessels as well as on the photothrombic efficiency was investigated using the chick chorioallantoic membrane (CAM) as in vivo model. NP characterization showed that the dye was more effectively entrapped in the polymeric matrix when its degree of lipophilicity increased. While less lipophilic compounds (TCPP, Ce(6)) extravasate rather easily, the more lipophilic dyes (TPP, Pheo-a) tend to remain inside the blood vessels. After injection of a drug dose of 1 mg/kg body weight and a drug-light application interval of 1 min, irradiation with light doses ranging from 5 to 20 J/cm(2) led to the highest photothrombic efficiency when using the NPs loaded with the most lipophilic molecule (TPP). The latter induced vascular damage, which was significantly higher than that observed with the other molecules tested. Thus, in addition to minimal leakage from blood vessels, the TPP in NP formulation exhibited photothrombic efficiency similar to Visudyne which was also tested in the CAM model. 相似文献
Summary A rapid and specific reversed-phase high-performance liquid chromatographic method (RPHPLC) is described for the determination of mebeverine hydrochloride in tablets. Elution was performed on an octyl silane column with a methanol-water mixture (75-25), containing 0.05% hexylamine as silanol-blocking agent, adjusted to pH 5.0 with phosphoric acid. The method gave accurate, precise and reproducible results. The mean recovery of the drug from six synthetic tablet mixtures was 100.0% with a relative standard deviation (RSD) of 0.94%. In order to test the specificity of the method, the interference of the degradation compounds of mebeverine hydrochloride and of the intermediates from the synthesis was investigated. None of them did interfere. By means of mass spectrometry and UV-spectrophotometry, the degradation compounds of mebeverine were identified as veratric acid and as 4-|ethyl-[2-(4-methoxyphenyl)-1-methylethyl]amino| 1-butanol. The stability study proved that mebeverine hydrochloride is very stable in tablets; the tablets still contain more than 95% of the declared drug potency after storage for more than one year at 50°C.Colofac; Duspatal; Duspatalin 相似文献
Reaction of (triphenylmethyl)silanetriol (1) with cyclopentadienyltitanium trichloride (CpTiCl3) in the presence of triethylamine as a HCl scavenger gave both compounds of a partial open-cage type {[Ph3CSiO(OH)]3(Ph3CSiO3/2)(CpTiO3/2)4} (2) and cube type (Ph3CSiO3/2CpTiO3/2)4 (3). The 1:1 reaction of 1 and CpTiCl3 in toluene solvent at reflux temperature for 3 d afforded compounds 2 (22%) and 3 (36%). When 1 is reacted with a 1.5 fold excess of CpTiCl3 under the same conditions, compound 3 was obtained in high yield (81%) along with 2 in trace quantities. Compounds 2 and 3 were fully characterized by the analyses of 1H, 13C, 29Si NMR, IR, and FAB MS data. The solid-state structure of 3 was determined by a single crystal X-ray diffraction study. Compound 3 had shown to have catalytic activity for the oxidation of alkenes such as 1-octene, cyclooctene, and norbornene with t-butyl hydrogen peroxide. The effect of solvent was observed in this epoxidation reaction. The order of reactivity were decreased as follows: CHCl3 > hexane THF. 相似文献
An accurate method for the determination of inorganic sulphate in synthetic detergents has been developed. After addition of a cationic surface-active agent (cetyl pyridinium chloride) to an anionic detergent, sulphate can be determined by means of indirect titration with EDTA, using a mixture of Metalphthalein and Naphthol Green B as indicator. 相似文献
Several polymeric materials were studied as membrane materials for potassium-selective ion-sensitive field-effect transistors (ISFETs) to overcome the problems related with the use of conventional plasticized poly(vinyl chloride) membranes casted on ISFET gate surfaces. Several acrylate materials, such as ACE, Epocryl and derivatives, showed no reproducible results. Three room-temperature vulcanizing (RTV)-type silicone rubbers were tested. The addition-type RTV-2 silicone rubber was not suitable as a membrane material, but the condensation-type RTV-1 and especially the RTV-2 silicone rubber showed good results. ISFETs with a Silopren membrane showed a durability of at least 2 months. 相似文献