首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   41篇
  免费   1篇
化学   4篇
数学   8篇
物理学   30篇
  2021年   1篇
  2020年   2篇
  2018年   1篇
  2017年   2篇
  2016年   2篇
  2013年   2篇
  2011年   2篇
  2010年   1篇
  2009年   4篇
  2008年   5篇
  2007年   4篇
  2006年   1篇
  2004年   1篇
  2003年   3篇
  2002年   3篇
  2001年   1篇
  2000年   1篇
  1999年   1篇
  1998年   1篇
  1997年   1篇
  1996年   1篇
  1995年   1篇
  1977年   1篇
排序方式: 共有42条查询结果,搜索用时 15 毫秒
31.
Detection thresholds were gathered for a 2 kHz Gaussian-shaped probe (standard deviation = 0.5 ms), centered at intervals of as little as half a millisecond over 0-30 ms following a 200 ms, 97 dB SPL, 2 kHz tone. Surprisingly, there were small, sudden rises and falls superimposed on each subject's generally smooth recovery. Even more obvious were nonmonotonicities in the standard deviation of the cumulative normal fitted to each threshold's psychometric function.  相似文献   
32.
33.
The parameters of a plasma produced upon the interaction of ultrashort laser pulses with cluster targets are measured by the methods of X-ray spectroscopy. The dependence of the plasma parameters on the initial properties of a cluster target (the design of a supersonic nozzle, the average size of clusters, the spatial inhomogeneity) and the laser pulse properties (its duration and contrast) is studied. The plasma diagnostics is performed using the model of formation of emission spectra, which was proposed earlier and includes a number of fitting parameters, which provide good agreement with experimental spectra. The systematic experimental studies performed by us showed that our model of cluster heating by ultrashort pulses is indeed a physical model, and the fitting parameters represent the average values of plasma parameters in the corresponding space-time regions.  相似文献   
34.
We have measured the X-ray emission spectra of a plasma generated by laser radiation with an intensity above 1019W/cm2 and a pulse duration of 30 fs acting upon an argon jet target with a large abundance of micron-sized clusters. The time variation of the X-ray yield from ions of various multiplicities, calculated within the framework of a nonstationary kinetic model, shows a good qualitative agreement with the experimental time-integrated spectrum.  相似文献   
35.
36.
Zaitsev  V. I.  Volkov  G. S.  Barykov  I. A.  Grabovskii  E. V.  Aleksandrov  V. V.  Boldarev  A. S.  Gasilov  V. A. 《JETP Letters》2008,88(9):582-585
JETP Letters - The results of a study of a radiating Z-pinch with a profiled initial gas-density distribution over the z axis are presented. The gas distribution with the density maximum and...  相似文献   
37.
38.
In this work a double‐crystal setup is employed to study compound refractive lenses made of single‐crystal diamond. The point spread function of the lens is calculated taking into account the lens transmission, the wavefront aberrations, and the ultra‐small‐angle broadening of the X‐ray beam. It is shown that, similarly to the wavefront aberrations, the ultra‐small‐angle scattering effects can significantly reduce the intensity gain and increase the focal spot size. The suggested approach can be particularly useful for the characterization of refractive X‐ray lenses composed of many tens of unit lenses.  相似文献   
39.
Psychometric functions (PFs) for forward-masked tones were obtained for conditions in which signal level was varied to estimate threshold at several masker levels (variable-signal condition), and in which masker level was varied to estimate threshold at several signal levels (variable-masker condition). The changes in PF slope across combinations of masker frequency, masker level, and signal delay were explored in three experiments. In experiment 1, a 2-kHz, 10-ms tone was masked by a 50, 70 or 90 dB SPL, 20-ms on-frequency forward masker, with signal delays of 2, 20, or 40 ms, in a variable-signal condition. PF slopes decreased in conditions where signal threshold was high. In experiments 2 and 3, the signal was a 4-kHz, 10-ms tone, and the masker was either a 4- or 2.4-kHz, 200-ms tone. In experiment 2, on-frequency maskers were presented at 30 to 90 dB SPL in 10-dB steps and off-frequency maskers were presented at 60 to 90 dB SPL in 10-dB steps, with signal delays of 0, 10, or 30 ms, in a variable-signal condition. PF slopes decreased as signal level increased, and this trend was similar for on- and off-frequency maskers. In experiment 3, variable-masker conditions with on- and off-frequency maskers and 0-ms signal delay were presented. In general, the results were consistent with the hypothesis that peripheral nonlinearity is reflected in the PF slopes. The data also indicate that masker level plays a role independent of signal level, an effect that could be accounted for by assuming greater internal noise at higher stimulus levels.  相似文献   
40.
The problem of increasing the mean size of clusters in gas-jet targets is tackled. Based on a mathematical model of clustering, the dependence of the cluster mean size on the nozzle length and rate of expansion is derived. The nozzle shape providing micrometer-size clusters is found. The parameters of gas-jet targets produced with this nozzle are studied in detail.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号