In this study, preparation of novel pH-sensitive N-doped carbon dots (NCDs) using glucose and urea is reported. The prepared NCDs present strong excitation-dependent fluorescence changes towards the pH that is a new behavior from these nanomaterials. By taking advantage of this unique behavior, two separated ratiometric pH sensors using emission spectra of the NCDs for both acidic (pH 2.0 to 8.0) and basic (pH 7.0 to 14.0) ranges of pH are constructed. Additionally, by considering the entire Excitation–Emission Matrix (EEM) of NCDs as analytical signal and using a suitable multivariate calibration method, a broad range of pH from 2.0 to 14.0 was well calibrated. The multivariate calibration method was independent from the concentration of NCDs and resulted in a very low average prediction error of 0.067 pH units. No changes in the predicted pH under UV irradiation (for 3 h) and at high ionic strength (up to 2 M NaCl) indicated the high stability of this pH nanosensor. The practicality of this pH nanosensor for pH determination in real water samples was validated with good accuracy and repeatability. 相似文献
A series of novel organosoluble polyamides (PAs) bearing different functional groups such as flexible ether, substituted imidazole, and xanthene rings and electron-withdrawing CF3 groups were synthesized from diamines and various dicarboxylic acids. The structures of diamines and PAs were fully characterized by elemental analysis, Fourier transform infrared spectroscopy, and proton nuclear magnetic resonance spectroscopy. The PAs showed good solubility in aprotic and polar organic solvents, with high thermal stability exhibiting the glass transition temperatures (Tgs) and 10% weight loss temperatures (T10%) in the range of 184–277°C and 410–480°C in N2 atmosphere, respectively. These polymers showed fluorescence emission upon irradiation with UV light. Diamine compounds and two of synthesized polymers were also screened for antibacterial activity against gram-positive and gram-negative bacteria, and the obtained results for all four combinations showed good inhibition. Extraction capability for heavy metal ions such as Cr3+, Pb2+, Hg2+, Cd2+, and Co2+ from aqueous solutions was also tested at 25°C and pH 7–8. 相似文献
A combination of periodic acid or oxone® and a catalytic amount of KBr in the presence of few drops of water, were used for the catalytic oxidation of urazoles and bis-urazoles to their corresponding triazolinediones under mild and heterogeneous conditions with moderate to excellent yields. 相似文献
A new optical chemical sensor has been developed for the selective determination of copper(II) ions in aqueous solutions. The reversible sensing system was prepared by incorporating 1-hydrpxy-2-(prop-2'-enyl)-4-(prop-2'-enyloxy)-9,10-anthraquinone (AQ) as a neutral Cu2+-selective fluoroionophore in the plasticized PVC membrane with potassium tetrakis(p-chlorophenyl borate) as an anionic additive. The response of the sensor is based on the fluorescence quenching of AQ by Cu2+ ions. At a pH 5.5, the proposed sensor displays a calibration response for Cu2+ over a wide concentration rang of 1.0 x 10(-2) to 1.0 x 10(-6) M, with a relatively fast response of less than 40 s. In addition to high stability and reproducibility, the sensor shows a unique selectivity towards Cu2+ ion with respect to common co-existing cations. The proposed fluorescence optode was applied successfully to the determination of copper(II) in black tea samples. 相似文献
In present study, a numerical model is employed to investigate the effects of different operating parameters and channel geometry on the performance of membrane humidifier. Simulations are performed by a commercial CFD code and based on user defined functions. Three-dimensional counter-flow humidifier model for a gas-to-gas case is considered. Results show that an increase in porosity or permeability leads to better humidification. Moreover, increase in inlet temperature of dry and wet channels as well as inlet mass flowrate of water vapor would enhance humidifying process. On the other hand, by reduction in inlet mass flowrate of gas channel and thickness of the porous medium in membrane, better humidifier performance would be achieved. To investigate the geometric parameters, three different channel types including stepped, sinusoidal and zigzag are considered. It is found that stepped geometry has the best performance in humidifying.
Interactions of diaza-18-crown-6 and diaza-15-crown-5, as electron donors, with 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ), as an electron acceptor, have been investigated spectrophotometrically in acetonitrile and chloroform solutions. The results indicated immediate formation of an electron donor-electron acceptor complex DA: [reaction in text] which is followed by two relatively slow consecutive reactions: [reaction in text]. The pseudo-first-order rate constants for the formation of the ionic intermediate and the final product have been evaluated at various temperatures by computer fitting of the absorbance time data to appropriate equations. The formation constants of the resulting DA complexes have also been determined. The influences of both the azacrown's structure and the solvent properties on the formation of DA complexes and the rates of subsequent reactions are discussed. 相似文献
A manganese(II) complex of 2,4,6-tris(2-pyridyl)-1,3,5-triazine (tptz) has been synthesized and characterized by single-crystal
X-ray diffraction, elemental analyses, IR, and UV–Vis spectroscopic techniques. Oxidation of alcohols to their corresponding
aldehydes and ketones was conducted by this catalyst using oxone (2KHSO5·KHSO4·K2SO4) as an oxidant under biphasic reaction conditions (CH2Cl2/H2O) and tetra-n-butylammonium bromide as phase transfer agent under air at room temperature. Easy preparation, mild reaction conditions,
high yields of the products, short reaction times, no further oxidation to the corresponding carboxylic acids, high selectivity
and inexpensive reagents make this catalytic system a useful oxidation method for aliphatic and benzylic alcohols. 相似文献
A new method, based on the concepts of matrix analysis as well as the learning capabilities of neural networks, for the analysis of nonlinear trusses under dynamic loading is presented. The method can be applied to static trusses too. While there have been attempts in the past to use neural networks to identify and model different structures based on data measured on structural response directly, the main feature and advantage of this new method is in its capability to model a nonlinear truss by assembling the data collected on the response of its members. The basics of the method are: (1) for each truss member, a neural network is trained to learn and simulate its load-response behavior, (2) the member neural networks are then assembled to build another neural network which can simulate the load-response behavior of the whole truss. Noticing test at member level is generally easier than at structure level, this can make the building of a neural network to simulate the response of the truss more affordable. Also this has potential application when it is hard to find a mathematical model from experimental data to describe the internal force vector for a truss, as well as identification and control of trusses where precise modeling of the structure is a key point to the success of the application. Prandtl Neural Network, developed recently by the authors for modeling of nonlinear hysteretic materials, has been improved and used in this study too. The improved version has been called Prandtl-2 Neural Network (PNN2) in this paper. The method has been applied to the static and dynamic analysis of a 3-bar and a 10-bar benchmark truss successfully, the results of which are reported in this paper. 相似文献
Dispersive liquid–liquid microextraction (DLLME) coupled with high-performance liquid chromatography (HPLC)-UV detection was applied for the extraction and determination of bisphenol A (BPA) in water samples. An appropriate mixture of acetone (disperser solvent) and chloroform (extraction solvent) was injected rapidly into a water sample containing BPA. After extraction, sedimented phase was analyzed by HPLC-UV. Under the optimum conditions (extractant solvent: 142 μL of chloroform, disperser solvent: 2.0 mL of acetone, and without salt addition), the calibration graph was linear in the range of 0.5–100 μg L−1 with the detection limit of 0.07 μg L−1 for BPA. The relative standard deviation (RSD, n = 5) for the extraction and determination of 100 μg L−1 of BPA in the aqueous samples was 6.0%. The results showed that DLLME is a very simple, rapid, sensitive and efficient analytical method for the determination of trace amount of BPA in water samples and suitable results were obtained. 相似文献