全文获取类型
收费全文 | 114篇 |
免费 | 6篇 |
国内免费 | 6篇 |
专业分类
化学 | 105篇 |
晶体学 | 2篇 |
力学 | 4篇 |
综合类 | 1篇 |
数学 | 8篇 |
物理学 | 6篇 |
出版年
2022年 | 2篇 |
2021年 | 3篇 |
2020年 | 3篇 |
2019年 | 3篇 |
2018年 | 1篇 |
2017年 | 2篇 |
2016年 | 4篇 |
2015年 | 3篇 |
2014年 | 5篇 |
2013年 | 9篇 |
2012年 | 11篇 |
2011年 | 8篇 |
2010年 | 10篇 |
2009年 | 3篇 |
2008年 | 10篇 |
2007年 | 8篇 |
2006年 | 7篇 |
2005年 | 2篇 |
2004年 | 6篇 |
2003年 | 5篇 |
2002年 | 7篇 |
2000年 | 2篇 |
1999年 | 2篇 |
1998年 | 2篇 |
1997年 | 2篇 |
1996年 | 1篇 |
1995年 | 1篇 |
1989年 | 1篇 |
1934年 | 2篇 |
1926年 | 1篇 |
排序方式: 共有126条查询结果,搜索用时 19 毫秒
71.
Two different in situ-polymerization techniques were studied, emulsion polymerization and combined emulsion/suspension polymerization, with styrene and methyl methacrylate in the presence of different multiwalled carbon nanotubes (MWCNTs). Molar masses and molar mass distributions were determined by size exclusion chromatography, and particle size of the emulsions by dynamic light scattering and rotation rheometry. The compatibility of the MWCNTs and monomer affected polymerization and therefore the molar masses. The MWCNTs stabilized the emulsions, and molar mass distributions narrowed with higher amounts of MWCNTs. In emulsion polymerization of styrene, MWCNTs increased the molar mass. The increase of molar mass was based on the compatible molecular structures of MWCNTs and styrene, so that individual nanotubes were covered by monomer clouds when initiator arrived. In combined emulsion/suspension polymerization of styrene, MWCNTs reacted with the initiator and there was less initiator to polymerize the monomer. There is probably a critical surface area of MWCNTs, for which more initiator is consumed in the reaction with MWCNTs than in polymerization of the monomer. In emulsion polymerization of MMA, monomer clouds around MWCNTs do not form due to incompatible molecular structures, and nanotubes do not enhance polymerization of MMA. In combined polymerization, the initiator is reacting with the nanotubes and the tube is acting as a carrier for initiator, and molar masses are higher. 相似文献
72.
Seth Madren Will McElroy Kristin Schultz-Kuszak Boris Boumajny Yao Shu Sabine Sautter Helen C. Zhao Abby Schadock-Hewitt Chris Chumsae Nancy Ball Xiaoying Zhang Kimberly Rish Shukui Zhang Christine Wurm Sumin Cai Scott P. Bauer Cinzia Stella Laura Zheng Brian Roper David A. Michels Gang Wu Bostjan Kocjan Matej Birk Simon Erik Erdmann Xiaoping He Brad Whittaker Yvonne Song Hannah Barrett Kevin Strozyk Ye Jing Long Huang Vishal Mhatre Paul McLean Tiantian Yu Huijuan Yang Minna Mattila 《Electrophoresis》2022,43(9-10):1050-1058
An international team spanning 19 sites across 18 biopharmaceutical and in vitro diagnostics companies in the United States, Europe, and China, along with one regulatory agency, was formed to compare the precision and robustness of imaged CIEF (ICIEF) for the charge heterogeneity analysis of the National Institute of Standards and Technology (NIST) mAb and a rhPD-L1-Fc fusion protein on the iCE3 and the Maurice instruments. This information has been requested to help companies better understand how these instruments compare and how to transition ICIEF methods from iCE3 to the Maurice instrument. The different laboratories performed ICIEF on the NIST mAb and rhPD-L1-Fc with both the iCE3 and Maurice using analytical methods specifically developed for each of the molecules. After processing the electropherograms, statistical evaluation of the data was performed to determine consistencies within and between laboratory and outlying information. The apparent isoelectric point (pI) data generated, based on two-point calibration, for the main isoform of the NIST mAb showed high precision between laboratories, with RSD values of less than 0.3% on both instruments. The SDs for the NIST mAb and the rhPD-L1-Fc charged variants percent peak area values for both instruments are less than 1.02% across different laboratories. These results validate the appropriate use of both the iCE3 and Maurice for ICIEF in the biopharmaceutical industry in support of process development and regulatory submissions of biotherapeutic molecules. Further, the data comparability between the iCE3 and Maurice illustrates that the Maurice platform is a next-generation replacement for the iCE3 that provides comparable data. 相似文献
73.
Minna Hakkarainen 《Polymer Degradation and Stability》2010,95(3):270-65
Single-drop micro-extraction (SDME), an emerging micro-extraction technique, was combined with multiple headspace (MHS) extraction to allow quantitative determination of lactide in thermally-oxidized polylactide. Different solvents, drop sizes and extraction times were tested to obtain best extraction efficiency and the method was further developed to obtain a linear regression plot for the multiple extractions. The combination of SDME and MHS extraction offered several advantages over traditional liquid-solid and headspace extraction techniques. No concentration step was needed and loss of volatiles was prevented as the ageing and extraction were performed in a closed system. Matrix effects, that disturb the quantitation of analytes in solid samples, were removed by the multiple headspace extraction. 相似文献
74.
Laura Yl‐Outinen Venla Harju Tiina Joki Janne T. Koivisto Jennika Karvinen Minna Kellomki Susanna Narkilahti 《Macromolecular bioscience》2019,19(7)
There is a clear need for novel in vitro models, especially for neuronal applications. Development of in vitro models is a multiparameter task consisting of cell‐, biomaterial‐, and environment‐related parameters. Here, three different human origin neuronal cell sources are studied and cultured in various hydrogel 3D scaffolds. For the efficient evaluation of complex results, an indexing method for data is developed and used in principal component analysis (PCA). It is found that no single hydrogel is superior to other hydrogels, and collagen I (Col1) and hyaluronan–poly(vinyl alcohol) (HA1‐PVA) gels are combined into an interpenetrating network (IPN) hydrogel. The IPN gel combines cell supportiveness of the collagen gel and stability of the HA1‐PVA gel. Moreover, cell adhesion is studied in particular and it is found that adhesion of neurons differs from that observed for fibroblasts. In conclusion, the HA1‐PVA‐col1 hydrogel is a suitable scaffold for neuronal cells and supports adhesion formation in 3D. 相似文献
75.
Simultaneous determination of antiviral drugs in chicken tissues by ultra high performance liquid chromatography with tandem mass spectrometry 下载免费PDF全文
ZhengCai Liu Fang Yang Minna Yao YongHui Lin ZhiJiao Su 《Journal of separation science》2015,38(10):1784-1793
An ultra high performance liquid chromatography with tandem mass spectrometry method was established for the rapid and simultaneous analysis of seven antiviral drugs, amantadine, rimantadine, memantine, moroxydine, imiquimod, oseltamivir, and acyclovir, in chicken liver, muscle, and egg. Homogenized samples were extracted with trichloroacetic acid and acetonitrile solutions and then purified by cation‐exchange solid‐phase extraction. The target drugs were analyzed by liquid chromatography with a UPLC BEH Amide column (2.1 mm × 100 mm, 1.7 μm) coupled with a tandem mass spectrometer operating in the positive multiple‐reaction mode. A perfectly linear relationship was obtained within the concentration ranges of 0.5–20 μg/L for acyclovir and 0.1–10 μg/L for the other six antiviral drugs. The average recoveries of the seven antiviral drugs using four addition levels in chicken liver, muscle, and eggs were 82.67–90.10, 82.30–92.27, and 81.98–93.77%, respectively, and the acceptable coefficients of variation were 5.18–9.88, 4.84–11.2, and 42.8–9.95%, respectively. The detection limits and detection capabilities of the analysis method for the seven antiviral drugs were in the ranges of 0.04–0.64 and 0.11–0.78 μg/kg, respectively. Additionally, an inter‐laboratory study among five laboratories further validated the method. 相似文献
76.
在文[1]和[2]中,各自得到了如下结果:一个循环布尔矩阵A是本原的当且仅当gcd(i2-i1,…,i1-i1,n)=1,其中A=Pi1十Pi2十…+Pi1,0≤i1<i2<…<i1≤n-1,P是对应于n阶循环置换(123…n)的置换矩阵.在本文中,先把此结果推广到群矩阵(一种循环矩阵的推广).其次,讨论群布尔矩阵的周期.给出了计算周期的算法,最后,探讨循环布尔矩阵A的使Am p=Am的最小正整数m. 相似文献
77.
Claudia Dell’Era Juha-Pekka PokkiPetri Uusi-Kyyny Minna PakkanenVille Alopaeus 《Fluid Phase Equilibria》2010
Isothermal vapour–liquid equilibrium was measured for the systems of diethyl sulphide + 1-butene, +cis-2-butene, and +2-methylpropene at 312.6 K, diethyl sulphide + n-butane was measured at 317.6 K, diethyl sulphide + trans-2-butene at 317.5 K, and diethyl sulphide + 2-methylpropane at 308.0 K. The pressure–temperature–total composition data were converted into pressure–temperature–liquid–vapour composition data using the method of Barker. Error estimates are provided for each variable. The isothermal parameters for the Wilson, NRTL and UNIQUAC activity coefficient models were regressed. The measurements were compared with the predictions by COSMO segment activity coefficient (COSMO-SAC) and UNIFAC. 相似文献
78.
79.
Several new symmetrical aromatic hydrocarbon bridged bipyridine ligands and their binuclear Ru (II) complexes have been designed, synthesized and characterized on the basis of 1H NMR, MS and HRMS. Their absorption and emission properties, electrochemical behaviors and electrochemical luminescence were investigated. All ruthenium complexes show characteristic MLCT absorption and similar redox potential. Among the three complexes reported, 4c has the best electrochemical luminescence property. 相似文献
80.
Sirkku E. Jäntti Minna Hartonen Mika Hilvo Heli Nygren Tuulia Hyötyläinen Raimo A. Ketola Risto Kostiainen 《Analytica chimica acta》2013
An ultra performance liquid chromatography–electrospray ionization-tandem mass spectrometry (UPLC–MS/MS) method was developed for the analysis of steroids and their glucuronides in urine samples. The method provides high sensitivity and fast analysis, as both steroids and their glucuronides can be analyzed directly without hydrolysis or complex sample preparation. The method was applied in profiling of targeted and nontargeted steroids and steroid glucuronides during pregnancy. The concentrations of 11 of 27 targeted steroids and steroid glucuronides and the concentrations of 25 nontargeted steroid glucuronides increased about 10–400 fold during the pregnancy. The concentrations of most of these 36 compounds began to increase in the first days of the pregnancy, increased gradually during the pregnancy, achieved a maximum in late pregnancy, and decreased sharply after delivery. Exceptionally, the concentrations of allopregnanolone and 17-hydroxypregnenolone started to increase later than those of the other steroids. Moreover, the concentrations of E2 glucuronides began to decrease one week before the delivery, in contrast to most of the steroids and steroid glucuronides, whose concentrations dropped sharply during the delivery. Concentrations of 34 compounds decreased noticeably when the subject was on sick leave owing a series of painful contractions. The results suggest that steroids and especially steroid glucuronides may provide a valuable diagnostic tool to follow the course of pregnancy. 相似文献