排序方式: 共有55条查询结果,搜索用时 0 毫秒
31.
32.
33.
SL Mironov E Skorova G Taschenberger N Hartelt VO Nikolaev MJ Lohse S Kügler 《BMC neuroscience》2009,10(1):29-11
Background
cAMP is an ubiquitous second messenger mediating various neuronal functions, often as a consequence of increased intracellular Ca2+ levels. While imaging of calcium is commonly used in neuroscience applications, probing for cAMP levels has not yet been performed in living vertebrate neuronal tissue before. 相似文献34.
We analyse the evolution of a two-stage chemical reaction betweentwo neighbouring plumes of reactants. Under the assumption thatthe plumes are approximately Gaussian we derive a system ofordinary differential equations for the total amount, the centroidand the variance of each reactant. We compare the solution ofthese equations with full numerical simulation of the reaction.Excellent agreement is obtained, with solution of the near-Gaussianmodel requiring considerably less computational effort thanthe full simulations. Of key importance is the yield of thereaction, and we discuss this feature in particular. 相似文献
35.
36.
Focusing coherent light through opaque strongly scattering media 总被引:1,自引:0,他引:1
We report focusing of coherent light through opaque scattering materials by control of the incident wavefront. The multiply scattered light forms a focus with a brightness that is up to a factor of 1000 higher than the brightness of the normal diffuse transmission. 相似文献
37.
Fourier transform mid-infrared spectroscopic detection is proposed as an on-line detection technique for the study of on-line
preconcentration processes in capillary electrophoresis (CE). The molecule-specific information contained in mid-IR spectra
can be used to directly determine the chemical compositions of individual zones and their boundaries. This paper reports on
pH junctions employed in myoglobin analysis. On-line mid-IR detection allowed the shape of the sample peak to be monitored
as well as the chemical compositions of the surrounding zones. From this information it was possible to obtain detailed insights
into the actual chemical compositions of the individual zones governing the efficiency of the preconcentration technique applied.
The principle of measurement outlined here can therefore also be regarded as a promising one for investigating other on-line
preconcentration techniques, like stacking, sweeping, and pH junction-sweeping among others.
Fourier transform mid-infrared spectroscopic detection has been employed in pH junction experiments. This approach can be
used to measure the chemical compositions of the phase boundaries formed, as well as the relative positions of the analyte
in the zones. The principle of this technique is demonstrated by measuring myoglobin (acetate buffer, pH 4.5) in an ammonium
BGE (pH 9.25) 相似文献
38.
39.
40.