The Fenton-Karma model is a simplification of complex ionic models of cardiac membrane that reproduces quantitatively many of the characteristics of heart cells; its behavior is simple enough to be understood analytically. In this paper, a map is derived that approximates the response of the Fenton-Karma model to stimulation in zero spatial dimensions. This map contains some amount of memory, describing the action potential duration as a function of the previous diastolic interval and the previous action potential duration. Results obtained from iteration of the map and numerical simulations of the Fenton-Karma model are in good agreement. In particular, the iterated map admits different types of solutions corresponding to various dynamical behavior of the cardiac cell, such as 1:1 and 2:1 patterns. (c) 2002 American Institute of Physics. 相似文献
It is widely believed that the velocity of information upsiloni encoded on an optical pulse is equal to the group velocity upsilong, at least when upsilong is less than the speed of light in vacuum c. On the other hand, several authors suggest that upsiloni=c, although the size of the signal traveling at this velocity may be small, thereby making it difficult to measure. Here, we measure upsiloni for pulses propagating through a resonant "slow-light" medium where upsilong approximately 0.006c. We find upsiloni=1.03c(+0.49c)-0.25c, or that upsiloni approximately 168upsilong, clearly demonstrating that the speed of information cannot be generally described by upsilong, but is characterized by its own velocity. 相似文献
We describe the operating characteristics of a new type of quantum oscillator that is based on a two-photon stimulated emission process. This two-photon laser consists of spin-polarized and laser-driven 39K atoms placed in a high-finesse transverse-mode-degenerate optical resonator and produces a beam with a power of approximately 0.2 microW at a wavelength of 770 nm. We observe complex dynamical instabilities of the state of polarization of the two-photon laser, which are made possible by the atomic Zeeman degeneracy. We conjecture that the laser could emit polarization-entangled twin beams if this degeneracy is lifted. 相似文献
Target identification remains challenging for the field of chemical biology. We describe an integrative chemical genomic and proteomic approach combining the use of differentially active analogs of small molecule probes with stable isotope labeling by amino acids in cell culture-mediated affinity enrichment, followed by subsequent testing of candidate targets using RNA interference-mediated gene silencing. We applied this approach to characterizing the natural product K252a and its ability to potentiate neuregulin-1 (Nrg1)/ErbB4 (v-erb-a erythroblastic leukemia viral oncogene homolog 4)-dependent neurotrophic factor signaling and neuritogenesis. We show that AAK1 (adaptor-associated kinase 1) is a relevant target of K252a, and that the loss of?AAK1?alters ErbB4 trafficking and expression levels,?providing evidence for a previously unrecognized role for AAK1 in Nrg1-mediated neurotrophic?factor signaling. Similar strategies should lead to the discovery of novel targets for therapeutic development. 相似文献
The European strategy for dioxin monitoring of the food chain has defined high-resolution gas chromatography coupled to high-resolution mass spectrometry (HRGC/HRMS) method as the confirmatory method that can provide reliable and comparable results at sub-parts per trillion (ppt) level. This paper describes the first inter-laboratory study on dioxins, furans and dioxin-like PCBs by HRGC/HRMS method in animal feedingstuffs. Two different statistical approaches (ISO 5725 and Cofino’s statistics) were used for the statistical evaluation. For this particular study, the performances of the HRGC/HRMS method seem to be congener-independent in repeatability and reproducibility conditions over a concentration range covering more than four orders of magnitude. Results clearly show the effect of precision loss below 0.1 ppt level per congener in repeatability conditions and below 0.2 ppt level per congener in reproducibility conditions. LODs reported by the laboratories give median values of 0.02 ng/kg for most of the toxic congeners. Relative standard deviation between the laboratories’ mean values using upper-bound approach for TEQ calculation is 6.2%, more than twice the maximum level set at 0.75 ng TEQ/kg of product. 相似文献
The determination of cysteine and homocysteine levels is of great current interest for the monitoring of desease states. A new colorimetric method for the simultaneous detection of l-cysteine and l-homocysteine has been developed. A fluorescein derivative reacts with the above amino acids, producing their respective thiazolidines resulting in color changes. Interference from other amino acids and proteins is minimal. 相似文献
Post‐polymerization modification is based on the direct polymerization or copolymerization of monomers bearing chemoselective handles that are inert towards the polymerization conditions but can be quantitatively converted in a subsequent step into a broad range of other functional groups. The success of this method is based on the excellent conversions achievable under mild conditions, the excellent functional‐group tolerance, and the orthogonality of the post‐polymerization modification reactions. This Review surveys different classes of reactive polymer precursors bearing chemoselective handles and discusses issues related to the preparation of these reactive polymers by direct polymerization of appropriately functionalized monomers as well as the post‐polymerization modification of these precursors into functional polymers. 相似文献
The novel amphipilic conjugate of a calix[4]arene with four Gd–1,4,7,10‐ tetra(carboxymethyl)‐1,4,7,10‐tetraazacyclododecane (DOTA) chelates has potential as a magnetic resonance imaging contrast agent, both in its monomeric and in its micellar form. The system, illustrated here with its nuclear magnetic relaxation profile, shows good relaxivities, thanks to its high rigidity.
Extracts of the marine sponge Caminus sphaeroconia showed potent activity in a screen for bacterial type III secretion inhibitors. Bioassay guided fractionation of the extract led to the isolation of the novel antimicrobial glycolipid caminoside A (1). The structure of caminoside A was elucidated by analysis of spectroscopic data and chemical degradation.[structure: see text] 相似文献
Recent developments in trapping efficiency inside ion trap mass spectrometer permitted to lower instrument detection limit (IDL). An IDL of 200 fg μl−1 injected with a signal-to-noise ratio of 5:1 for tetrachlorodibenzo-p-dioxin (TCDD) was obtained by gas chromatography coupled to a quadrupole ion storage mass spectrometer in tandem mode (GC/MS/MS). Coupling large volume programmable temperature vaporizer (PTV-LV) injection to GC/MS/MS provides an alternative and complementary method to classical splitless-GC injection connected to high-resolution mass spectrometry (splitless-GC/HRMS) method for dioxin monitoring in food and feed.
An injection volume of 10 μl was found to be the best compromise between the sensitivity requirements and the robustness required for a high throughput method. PTV-LV-GC/MS/MS and Splitless-GC/HRMS were compared by performing analysis on five different matrices such as beef fat, yolk eggs, milk powder, animal feed and serum samples covering a concentration range of two orders of magnitude (i.e. 0.2–25 ng WHO-TEQ kg−1). An analysis of variance (ANOVA) was carried out. Fisher tests pointed out that the method effect for all the 2,3,7,8 congeners was not significant, indicating that the null hypothesis (H0: μ1=μ2=…=μn) was not rejected. Moreover, the interaction effects between methods and matrices were not significant for most of the 2,3,7,8 congeners. However, three congeners (2,3,7,8-TCDF; 1,2,3,4,7,8-HxCDD and 1,2,3,4,6,7,8-HpCDD) were characterized by P-values lower than the significance level (=0.05). In toxic equivalence (TEQ), the study showed that no significant bias was observed between the two methods. Consequently, PTV-LV-GC/MS/MS is an attractive technique and can be used as a cost effective complementary method to HRMS for dioxin levels monitoring in food and feed. 相似文献