The first inherently chiral azacalix[4]arene has been prepared by introducing three benzyl groups onto the nitrogen bridges. The highly enantioenriched compound was easily obtained via a moderately enantioselective cyclization followed by a simple crystallization procedure. NMR and X-ray crystallographic studies revealed that easy access to the enantiomer was permitted by the non-racemizable 1,3-alternate conformation in solution, up to 110 °C, as well as by the preferential crystallization of a racemic compound. 相似文献
The possibility of constructing an interdigitated array electrode (IDA) with a submicrometre gap is proposed in which adjacent microband electrodes are separated from each other by an insulated step. Then the IDA is an assembly of protrusive and hollow microband electrodes. The unit model of the IDA consisted of half of the lower (hollow) microband electrode, an insulated step and half of the upper (protrusive) microband electrode with a finite thickness on the step. The boundary value problem involving the two-dimensional Laplace equation is presented for redox cycling at the IDA under diffusion control and is solved numerically by a boundary element method. The steady-state current was computed as a function of the height of the step and the thickness of the upper electrode. It was larger than the current at the ordinary IDA, partly because the true electrode area was larger than the area of the ordinary IDA. The current varied linearly with the logarithm of the step height. It was expressed by a simple approximate equation in order to facilitate prediction of its numerical value. 相似文献
Fluoxymesterone, an anabolic steroid with the 17alpha-methyl,17beta-hydroxy group, has been developed as an oral formulation for therapeutic purposes. However, it is also used illegally in racehorses to enhance racing performance. In this study, we detected 9alpha-fluoro-17,17-dimethyl-18-norandrostane-4,13-dien-11beta-ol-3-one by gas chromatography/mass spectrometry (GC/MS), which has not been reported as a fluoxymesterone metabolite so far in horse. It was synthesized for use as a reference standard, and characterized on the basis of (1)H NMR and (13)C NMR spectra, as well as GC/MS EI mass spectra of TMS derivatives. It was excreted as the main metabolite in horse urine, and its reference standard could be synthesized easily. Therefore, this metabolite could be a useful target for a doping test of fluoxymesterone in racehorses. 相似文献
Water droplets were formed spontaneously at the interface of the 2-nitrophenyloctyl ether and aqueous phases on the oil phase side when the oil contained tetraalkylammonium chloride without surfactants. The droplets, less than some micrometers in diameter, gathered at the interface. The number density of the droplets was proportional to the concentration of tetraethylammonium chloride, and hence this salt should be responsible for the formation of the droplets as a surfactant. When positive voltage was applied to the aqueous phase against the oil, the droplets departed from the interface toward the oil bulk. The droplets should be negatively charged by chloride. The adsorption model of the salt was suggested, in which chloride is immobilized at the interface on the aqueous side electrostatically with tetraethylammonium ion on the oil side. 相似文献
An octadecylsilica (ODS) column modified with zwitterionic/nonionic mixed surfactants was evaluated for the direct injection determination of inorganic anions in biological fluids by ion chromatography. A zwitterionic surfactant (sulfobetaine-type) and a nonionic surfactant (polyoxyethylene-type) were used for a stationary-phase modification. When aqueous electrolyte solutions with concentrations of sub-mM to several mM were used as a mobile phase, the zwitterionic surfactant coated on the ODS surface exhibited unique separation selectivity for ionic species, while the nonionic surfactant coated on the ODS might have formed a hydrophilic network over the ODS surface and restricted matrix proteins from adsorbing on the stationary phase. Consequently, the mixed surfactant-modified column system allowed an efficient ion chromatographic separation of inorganic anions as well as a size-exclusive removal of column-fouling proteins. This separation system was applied to the direct injection determination of UV-absorbing anions in human saliva. The detection limits for nitrite, nitrate, iodide and thiocyanate were 3.1, 2.7, 4.5 and 25 microM, respectively, with UV detection at 210 nm (injection volume; 20 microl), and their relative standard deviations for 5 replicate measurements of saliva samples spiked with 100 microM each of those anions were 1.4, 0.9, 2.2 and 5.5%, respectively. 相似文献
The authors describe a pipette type of biosensor for detecting target genes and using a zinc finger protein fused to luciferase (ZF luciferase). The ZF protein binds to a specific DNA sequence, and the target double-stranded (ds) DNA can be detected by monitoring the enzymatic activity of ZF luciferase. A small avidin-immobilized reaction plate is placed on a plastic pipette tip (referred to as Biologi tip). The dsDNA detection procedures are carried out by using a programmable dispensing robot equipped with a photodetector. These procedures include (a) the aspiration of an analyte to capture the biotinylated target dsDNA (a product of a polymerase chain reaction) on the small reaction plate inside the pipette tip, (b) the introduction of ZF luciferase and luciferin into the pipette tip, and (c) migration of the pipette tip to the detection port to measure bioluminescence on the small reaction plate. The emission originating from luciferase activity is observed on the reaction plate containing immobilized biotin-tagged target dsDNA, whereas plates containing non-target or biotinylated single-stranded DNA only do not yield a signal. The intensity of emission increases proportionally to the concentration of dsDNA, and the detection limit of the target dsDNA is as low as 62 pM. An actual genomic DNA sample from Escherichia coli O157 was successfully detected by this automatic analyzer using the Biologi tip equipped with a reaction plate. This indicates that this system has a large potential for practical applications, including in particular point-of-care analyses in hygiene control, food safety testing, and clinical diagnosis.
Graphical abstract A pipette-type biosensor was developed to detect target genes using a luciferase-fused zinc finger protein, where a small NeutrAvidin-immobilized reaction plate was placed on the tip, and the biotinylated target double-stranded DNA was detected by monitoring the bound luciferase activity.
N-Aryl-protecting groups were introduced in glucosamines to achieve β-selective glycosylation. Various N-aryl aminosugars were synthesized via Buchwald–Hartwig reaction. Glycosylation using glycosyl trichloroacetimidates of N-aryl aminosugars smoothly proceeded in the presence of trimethylsilyl trifluoromethanesulfonate. Use of a glycosyl donor comprising an electron-donating 2,4-dimethoxyphenyl (DMP) group led to the glycosylation proceeding with high β selectivity. This stereoselectivity seemed to be derived from the formation of an aziridine intermediate. The DMP-protecting group can be removed immediately by using ammonium hexanitratocerate (IV). 相似文献