全文获取类型
收费全文 | 273篇 |
免费 | 14篇 |
国内免费 | 1篇 |
专业分类
化学 | 205篇 |
力学 | 8篇 |
数学 | 29篇 |
物理学 | 46篇 |
出版年
2023年 | 4篇 |
2022年 | 11篇 |
2021年 | 12篇 |
2020年 | 12篇 |
2019年 | 13篇 |
2018年 | 17篇 |
2017年 | 14篇 |
2016年 | 19篇 |
2015年 | 18篇 |
2014年 | 25篇 |
2013年 | 33篇 |
2012年 | 16篇 |
2011年 | 20篇 |
2010年 | 6篇 |
2009年 | 13篇 |
2008年 | 8篇 |
2007年 | 9篇 |
2006年 | 8篇 |
2005年 | 7篇 |
2004年 | 5篇 |
2003年 | 2篇 |
2002年 | 2篇 |
2001年 | 1篇 |
2000年 | 2篇 |
1999年 | 3篇 |
1998年 | 2篇 |
1994年 | 1篇 |
1992年 | 1篇 |
1991年 | 2篇 |
1985年 | 1篇 |
1975年 | 1篇 |
排序方式: 共有288条查询结果,搜索用时 11 毫秒
101.
102.
103.
The structure, 14N NQR parameters, electronic spectra, and hyperplarizability of [Cr(CO)5py] in seven different solvents were theoretically computed with MPW1PW91 method based on Polarizable Continuum Model (PCM). The substituent effects in para- substituted Cr(CO)5–pyridine complexes have been evaluated. The results indicate that both polarity of solvents and the substituents have played a significant role on the structures and properties of complexes. The study also shows that the structural and solvent modification change the NLO properties. 相似文献
104.
Quantitative Measurement of Transmitters in Individual Vesicles in the Cytoplasm of Single Cells with Nanotip Electrodes 下载免费PDF全文
Johan Dunevall Hoda Fathali Prof. Andrew G. Ewing 《Angewandte Chemie (International ed. in English)》2015,54(41):11978-11982
The quantification of vesicular transmitter content is important for studying the mechanisms of neurotransmission and malfunction in disease, and yet it is incredibly difficult to measure the tiny amounts of neurotransmitters in the attoliter volume of a single vesicle, especially in the cell environment. We introduce a novel method, intracellular vesicle electrochemical cytometry. A nanotip conical carbon‐fiber microelectrode was used to electrochemically measure the total content of electroactive neurotransmitters in individual nanoscale vesicles in single PC12 cells as these vesicles lysed on the electrode inside the living cell. The results demonstrate that only a fraction of the quantal neurotransmitter content is released during exocytosis. These data support the intriguing hypothesis that the vesicle does not open all the way during the normal exocytosis process, thus resulting in incomplete expulsion of the vesicular contents. 相似文献
105.
A simple and efficient method, ionic liquid-based dispersive liquid-liquid microextraction combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV), has been applied for the extraction and determination of some antioxidants (Irganox 1010, Irganox 1076 and Irgafos 168) in water samples. The microextraction efficiency factors were investigated and optimized: 1-hexyl-3-methylimidazolium hexafluorophosphate [C(6)MIM][PF(6)] (0.06 g) as extracting solvent, methanol (0.5 mL) as disperser solvent without salt addition. Under the selected conditions, enrichment factors up to 48-fold, limits of detection (LODs) of 5.0-10.0 ng/mL and dynamic linear ranges of 25-1500 ng/mL were obtained. A reasonable repeatability (RSD≤11.8%, n=5) with satisfactory linearity (r(2)≥0.9954) of the results illustrated a good performance of the presented method. The accuracy of the method was tested by the relative recovery experiments on spiked samples, with results ranging from 85 to 118%. Finally, the method was successfully applied for determination of the analytes in several real water samples. 相似文献
106.
Walid Ibrahim Hesham El-Sayed Amr El-Chouemie Hoda Amer 《European Journal of Operational Research》2009,199(3):630-639
The increasing complexity of today’s system-on-a-chip designs is putting more pressure on the already stressed design verification process. The verification plan must cover several individual cores as well as the overall chip design. Conditions to be verified are identified by the system’s architects, the designers, and the verification team. Testing for these conditions is a must for the design to tape out, especially for high priority conditions. A significant bottleneck in the verification process of such designs is that not enough time is usually given to the final coverage phase, which makes computing cycles very precious. Thus, intelligent selection of test vectors that achieve the best coverage using the minimum number of computing cycles is crucial for on time tape out. This paper presents a novel heuristic algorithm for test vectors selection. The algorithm attempts to achieve the best coverage level while minimizing the required number of computing cycles. 相似文献
107.
A simple and sensitive methodology based on liquid-liquid-liquid microextraction (LLLME) followed by high-performance liquid chromatography-ultraviolet detection (HPLC-UV) has been successfully developed for the determination of atorvastatin (AT) in human plasma. AT was first extracted from 4.5 mL acidic aqueous sample (diluted plasma, donor phase, pH 1) at temperature 45 °C through 400 μL 1-octanol for 4.5 min, while being agitated by a stirring bar at 1250 rpm. Then, a 5.5 μL free suspended basic aqueous droplet (acceptor phase, pH 10) was delivered to the top-center position of the organic membrane. The mixture was stirred at 650 rpm for 7.5 min and the analyte was back-extracted into the droplet. Finally, the acceptor phase was taken into a microsyringe and injected directly into the HPLC. An enrichment factor of 187 along with substantial sample clean up was obtained under the optimized conditions. The calibration curve showed linearity in the range of 1-500 ng mL−1 with regression coefficient corresponding to 0.996. Limits of detection (S/N = 3) and quantification (S/N = 10) were 0.4 and 1 ng mL−1, respectively. A reasonable relative recovery (91%) and satisfactory intra-assay (4.4-7.0%, n = 6) and inter-assay (4.9-7.7%, n = 8) precision illustrated good performance of the analytical procedure. This technique was eventually applied for the determination of AT in human plasma after oral administration of 40 mg single dose of drug. The protocol proved to be highly cost-effective and reliable for the screening purpose. 相似文献
108.
Using van der Waals corrected density functional theory (vdW-DF) method we have investigated the adsorption of acetone molecule on pristine and Pt-doped graphene. Several active sites for both the interacting systems have been considered in the adsorption process including full geometry optimization. We have analyzed the structural and electrical properties of energetically favorable configurations. The results show that adsorption of acetone molecule on the Pt-doped graphene is energetically preferable. The binding energy and bonding distance are determined to be -5.277 eV and 2.206 Å, respectively, accompanying with charge transfer of 1.11 e. Furthermore, the Pt-O bond is rather significantly elongated when acetone is adsorbed on Pt-doped graphene. Compared to pristine graphene, the Pt-doped graphene has stronger interaction with the acetone and may provide more sensitive signal for a single acetone molecule. Meanwhile, practically, the band gap of Pt-doped graphene would become reduced after acetone adsorption. Consequently, our first-principles study presents evidence for a coherent benchmark for the applicability of Pt-doped graphene for acetone adsorption and detection. 相似文献
109.
A four-body theoretical study of the single charge transfer process in collision of energetic alpha ions with helium atoms in their ground states is presented. The model utilizes the Coulomb–Born distorted wave approximation with correct boundary conditions to calculate the single-electron capture differential and integral cross sections. The influence of the dynamic and static electron correlations on the capture probability is investigated. The results of the calculations are compared with the recent experimental measurements for differential cross sections and with the other theoretical manipulations. The results for scattering at extreme forward angles are in good agreement with the experimental measurements, but in other scattering angles the agreement is poor. However, the present four-body results for integral cross sections are in excellent agreement with the experimental data. 相似文献
110.