This paper describes a liquid chromatography-electrospray-tandem mass spectrometry (LC-ESI-MS/MS) for the qualitative and quantitative analysis of three isoflavone aglycones (glycitein, daidzein and genistein) in human serum. Positive ion mode was used for the detection of these compounds and selective reaction monitoring (SRM) was employed for quantitative measurement. The SRM transitions monitored were as 285.0 → 242.0, 270.0 for glycitein, 255.0 → 137.0, 153.0, 181.0, 199.0 for daidzein and 271.0 → 153.0, 215.0 for genistein. d3-Daidzein was used as an internal standard for quantitative measurement. The linearity was good from 0.5 to 500 ng/ml. The detection limit based on a signal-to-noise ratio of three was 0.27, 0.38 and 0.29 ng/ml for glycitein, daidzein and genistein, respectively. A newly developed solid phase extraction (SPE) procedure was developed for sample pre-treatment. Good recovery, 92.3-103.2%, for three isoflavone aglycones were obtained. This newly developed method was successfully applied to evaluate isoflavone pharmacokinetic in human serum after oral administration. 相似文献
The synthesis of oligonucleotides in solution using a soluble, ionic liquid based support is described. Short oligomers of varying base composition were synthesized using this method in high yields and high purity, requiring no chromatography for purification prior to cleavage from the support. The solution-phase-synthesized oligomers were compared to the same sequences prepared using standard gene machine techniques by LCMS. This methodology may provide a cheaper route for the large-scale synthesis of oligonucleotides. 相似文献
A CE-resonance Raman spectroscopy (CE-RRS) method based on MEKC and sweeping-MEKC modes is described. A nonfluorescent compound, malachite green (MG), and a doubled Nd:YAG laser (532 nm, 300 mW) were selected as model compound and light source, respectively. In order to carry out a quantitative analysis of MG, a monochromator (effective bandwidth, 0.4 nm) was used to collect the specific Raman line at 1616 cm(-1) (N-phi and C-C stretch, corresponding to 582 nm when the wavelength of the exciting source was 532 nm). As a result, the LOD for MG was 10 ppm, based on the MEKC/RRS mode. This could be improved to 5 ppb when the sweeping-MEKC/RRS mode was applied. Furthermore, with the addition of nano-size silver colloids to the CE buffer the detection limits can be further improved, but the data obtained with surface-enhanced resonance Raman spectroscopy (SERRS) are less useful for quantitative purposes. 相似文献
A beam-folding technique in optical interferometry, where the number of beam folds used can be very large, is reported. This technique can be used as a low-cost position-tracking method in a Fourier transform spectrometer (FTS) to cover the broad spectral range from UV to IR. The main advantage gained is the simple position-tracking algorithm used in sampling the interferogram. We have developed a UV-visible FTS, whose wavelength coverage is limited only by the optical elements (350 nm(-1) microm with off-the-shelf components). Preliminary results show that it can achieve a resolution of approximately 4 cm(-1) even with a ball-bearing translation stage. 相似文献
Phosphorescent conjugated polymers consisting of alternating p‐phenylene‐ethynylene and ‘para‐’ or ‘meta‐type’ Pt(II)‐salphen luminophore units have been synthesized. Side‐arms bearing different substituents (n‐alkoxy and acetylated‐sugar) have afforded contrasting emission properties that are attributed to the polymer conformation, extent of π‐stacking interactions and differences in chemical structure. Intriguing selectivity in luminescent sensing of metal ions has been observed.
We introduce a custom-built stress-controlled shear cell coupled to a confocal microscope for direct visualization of constant-stress shear deformation in soft materials. The torque generator is a cylindrical Taylor–Couette system with a Newtonian fluid between a rotating inner bob and a free-to-move outer cup. A spindle/cone assembly is coaxially coupled to the cup and transfers the torque exerted by the fluid to the sample of interest in a cone-and-plate geometry. We demonstrate the performance of our device in both steady-state and transient experiments with different viscoelastic materials. Our apparatus can conduct unidirectional constant-stress experiments as accurately as most commercial rheometers, with the capability to directly visualize the flow field using tracer particles. Further, our step-stress experiments on viscoelastic materials are devoid of creep ringing, which is an advantageous aspect of our torque generation mechanism. We believe that the device presented here could serve as a powerful and cost-effective tool to investigate the microstructural determinants of nonlinear rheology in complex fluids. 相似文献
A theoretical analysis of convective instability driven by buoyancy forces under the transient concentration fields is conducted in an initially quiescent, liquid-saturated, cylindrical porous column. Darcy’s law and Boussinesq approximation are used to explain the characteristics of fluid motion and linear stability theory is employed to predict the onset of buoyancy-driven motion. Under the principle of exchange of stabilities, the stability equations are derived in self-similar boundary-layer coordinate. The present predictions suggest the critical $R_D$, and the onset time and corresponding wavenumber for a given $R_D$. The onset time becomes smaller with increasing $R_D$ and follows the asymptotic relation derived in the infinite horizontal porous layer. 相似文献