首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   62篇
  免费   0篇
  国内免费   1篇
化学   45篇
晶体学   1篇
力学   6篇
综合类   1篇
数学   3篇
物理学   7篇
  2021年   2篇
  2015年   1篇
  2013年   3篇
  2012年   7篇
  2011年   4篇
  2010年   1篇
  2009年   3篇
  2008年   4篇
  2007年   5篇
  2006年   1篇
  2005年   1篇
  2004年   9篇
  2003年   15篇
  2002年   1篇
  2000年   1篇
  1999年   1篇
  1998年   1篇
  1991年   1篇
  1989年   1篇
  1981年   1篇
排序方式: 共有63条查询结果,搜索用时 187 毫秒
11.
X‐ray optics called multilayer Laue lenses (MLLs) provide a promising path to focusing hard X‐rays with high focusing efficiency at a resolution between 5 nm and 20 nm. MLLs consist of thousands of depth‐graded thin layers. The thickness of each layer obeys the linear zone plate law. X‐ray beamline tests have been performed on magnetron sputter‐deposited WSi2/Si MLLs at the Advanced Photon Source/Center for Nanoscale Materials 26‐ID nanoprobe beamline. However, it is still very challenging to accurately grow each layer at the designed thickness during deposition; errors introduced during thickness measurements of thousands of layers lead to inaccurate MLL structures. Here, a new metrology approach that can accurately measure thickness by introducing regular marks on the cross section of thousands of layers using a focused ion beam is reported. This new measurement method is compared with a previous method. More accurate results are obtained using the new measurement approach.  相似文献   
12.
This paper describes fabrication methods used to demonstrate the advantages of nested or Montel optics for micro/nanofocusing of synchrotron X-ray beams. A standard Kirkpatrick-Baez (KB) mirror system uses two separated elliptical mirrors at glancing angles to the X-ray beam and sequentially arranged at 90° to each other to focus X-rays successively in the vertical and horizontal directions. A nested KB mirror system has the two mirrors positioned perpendicular and side-by-side to each other. Compared to a standard KB mirror system, Montel optics can focus a larger divergence and the mirrors can have a shorter focal length. As a result, nested mirrors can be fabricated with improved demagnification factor and ultimately smaller focal spot, than with a standard KB arrangement. The nested system is also more compact with an increased working distance, and is more stable, with reduced complexity of mirror stages. However, although Montel optics is commercially available for laboratory X-ray sources, due to technical difficulties they have not been used to microfocus synchrotron radiation X-rays, where ultra-precise mirror surfaces are essential. The main challenge in adapting nested optics for synchrotron microfocusing is to fabricate mirrors with a precise elliptical surface profile at the very edge where the two mirrors meet and where X-rays scatter. For example, in our application to achieve a sub-micron focus with high efficiency, a surface figure root-mean-square (rms) error on the order of 1 nm is required in the useable area along the X-ray footprint with a ∼0.1 mm-diameter cross section. In this paper we describe promising ways to fabricate precise nested KB mirrors using our profile coating technique and inexpensive flat Si substrates.  相似文献   
13.
We report on a novel concept of sample loading for microfluidic devices using a benchtop centrifuge and a magnetically actuated circular closed-loop PCR microchip as a model system. The PCR mixture and the ferrofluid were loaded into a specially designed microchip. The microchip was then placed in an off-the-shelf 50-mL tube and centrifuged. The strong centrifugal force drives the PCR mixture and the ferrofluid into the microchannels of the microchip, and simultaneously expels any trapped microbubbles. PCR was successfully carried out on single and parallel closed-loop PCR microchips. The addition of a few off-chip handling steps allows great simplification of the device design. This new loading concept may be useful for designing robust and low-cost lab-on-a-chip devices because benchtop centrifuges are quite common in most laboratories.
Figure
This paper reports a novel concept of sample loading for microfluidic devices using a benchtop centrifuge. The addition of a few simple off-chip handling steps allows designing robust and low-cost lab-on-a-chip devices.  相似文献   
14.
PEPT study of particle motion for different riser exit geometries   总被引:1,自引:0,他引:1  
Laboratory and industrial risers are equipped with exits of many different layouts, and numerous publications discuss the influence of riser exit geometry on local and overall solids hydrodynamics in the riser. The present paper reviews literature findings--mostly based upon indirect experimental techniques and often somewhat contradictory, Direct measurement of particle velocity and particle occupancy near and in the riser exit provide a better indication of the effect of riser exit geometry. Positron Emission Particle Tracking (PEPT) was used in this work for the first time to investigate the exit region of the riser, An abrupt or sharp exit causes particles to be knocked out of the gas flow, so forming a recirculation or reflux region in the upper part of the riser. This is much less pronounced with a curved or gradual exit.  相似文献   
15.
A novel method to separate and simultaneously record the Moiré interferometry fringe patterns of three deformation fields with only one CCD camera is developed; details of its operation principle, key points and error analysis are presented. With this technique, the deformation inU, V andW fields can be measured simultaneously, so dynamic test with comprehensive information can be performed. The advantage of this technique over other similar techniques lies in its simplicity, easy implementation and low cost. An application of this technique is given to show its feasibility. Technical problems that may be caused with this technique are also analyzed.  相似文献   
16.
Steady-state, nonlinear potential solutions in a two-fluid plasma are formulated in terms of an integral equation that expresses the conservation of total pressure. By appropriately specifying the conservation constants and boundary conditions of the effective potential function, the integral curves yield, respectively, three types of solutions: nonlinear Langmuir waves, ion-acoustic solitons, and double layers. The similarities and differences of the existence conditions for these nonlinear potential structures are discussed  相似文献   
17.
The nanoscale structure of multilayer metal/phosphonate thin films prepared via a layer-by-layer assembly process was studied using specular X-ray reflectivity (XRR), X-ray fluorescence (XRF), and long-period X-ray standing wave (XSW) analysis. After the SiO(2) X-ray mirror surfaces were functionalized with a monolayer film terminated with phosphonate groups, the organic multilayer films were assembled by alternating immersions in (a) aqueous solutions containing Zr(4+), Hf(4+), or Y(3+) cations and then (b) organic solvent solutions of PO(3)-R-PO(3), where R was a porphyrin or porphyrin-square spacer molecule. The different heavy metal cations provided X-ray fluorescence marker layers at different heights within the different multilayer assemblies. The XSW measurements used a 22 nm period Si/Mo multilayer mirror. The long-period XSW generated by the zeroth-order (total external reflection) through fourth-order Bragg diffraction conditions made it possible to examine the Fourier transforms of the fluorescent atom distributions over a much larger q(z)() range in reciprocal space than previously achieved.  相似文献   
18.
Chianéa T  Assidjo NE  Cardot PJ 《Talanta》2000,51(5):835-847
Field flow fractionation (FFF) methods were conceptualised in the late 1960s by J.C Giddings. These techniques are particularly suited for the retention and separation of micron and sub-micron sized particles. Systematic technological development as well as methodological procedures were established to achieve separations over the last 30 years. The elution mechanism of micron sized species is now known as 'steric/hyperlayer'. Cells are micron sized particles of life science interest, in particular those living in suspension. The separation of cells according to differences in their biophysical characteristics is therefore possible using the FFF principle. In the first part of this report, characteristics of classical cell separation methodologies are recounted as well as the specific features of FFF. In the second part, a review of cell separations or purifications obtained with sedimentation FFF techniques is given and FFF trends in cell separation is developed.  相似文献   
19.
Cationic polymers prepared from partially neutralized ferric chloride solutions were investigated using photon correlation spectroscopy (PCS) techniques. To study the speciation and yield of the polymers, FeCl(3) solutions were hydrolyzed by adding NaHCO(3) solution for a range of hydrolysis ratios (B=[OH]/Fe(T)) of 0 to 2.0 under different base addition rates. It was observed that the prepared solution has a higher degree of polymerization at a higher base addition rate. The "B rate" (R(B), 1/time), i.e., the rate of change of B during preparation, was found to have a dramatic effect on the speciation of the partially neutralized ferric chloride solution. High-yield inorganic iron(III) polymer ( approximately 80%) can be produced in a specific range of B rates. These iron(III) polymers, having a size ranging from 3 to 7 nm, were stable without precipitation of ferric hydroxide microcolloids after aging for 2 weeks.  相似文献   
20.
Carbohydrates on cell surfaces are critical components of the extracellular landscape and contribute to cell signalling, motility, adhesion and recognition. Multivalent effects are essential to these interactions that are inherently weak. Carbohydrate‐functionalised surfaces meet an important need for studying the multivalent interactions between carbohydrates and other biomolecules. Innovations in nanomaterials are revolutionising how these carbohydrate interfaces are studied and underscore their importance in the cosmos of biochemical interactions.  相似文献   
[首页] « 上一页 [1] 2 [3] [4] [5] [6] [7] 下一页 » 末  页»
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号