排序方式: 共有57条查询结果,搜索用时 15 毫秒
11.
Solberg LB Melhus G Brorson SH Wendel M Reinholt FP 《Micron (Oxford, England : 1993)》2006,37(4):347-354
The main purpose of this study was to examine whether antigens can be retrieved by heating Lowicryl sections of paraformaldehyde-fixed (PFF) tissues. Thus the intensity of the immunogold signal for two bone proteins (Nucleobindin (Nuc) and osteoadherin (OSAD)) was compared in retrieved and non-retrieved sections of PFF rat bone. As an additional experiment, the effect of antigen retrieval (for Nuc) in sections of tissue primary stabilized by high pressure freezing with subsequent freeze substitution (HPF-FS) was studied. Finally, the tissue distribution patterns of Nuc labeling were compared in non-retrieved HPF-FS sections to that of retrieved and non-retrieved PFF sections. Antigen retrieval in Lowicryl sections of PFF tissues showed significantly enhanced labeling intensity for both proteins in all compartments where they are known to occur. Retrieved PFF Lowicryl sections showed only minor ultrastructural differences compared to non-retrieved ones. Retrieval of HPF-FS sections exhibited no enhancement of labeling but rather a slight reduction, which was significant in the cytoplasm and in cartilage. Furthermore, striking ultrastructural differences were observed in retrieved HPF-FS sections compared to non-retrieved ones with loss of coherence and structure in sections subjected to heating. Comparison of the distribution patterns of Nuc in the sections of PFF and HPF-FS tissues showed discrepancy in most compartments. Antigen retrieval by heating Lowicryl sections of PFF tissues significantly enhances immunogold labeling in all cell compartments where the bone proteins are known to occur. However, the procedure may distort the tissue distribution pattern of bone proteins. 相似文献
12.
13.
14.
15.
Norling L Lute S Emery R Khuu W Voisard M Xu Y Chen Q Blank G Brorson K 《Journal of chromatography. A》2005,1069(1):79-89
We evaluated viral clearance in multiply-cycled anion-exchange media run in flow-through mode. We found that anion-exchange columns do not lose viral clearance capacity after extensive re-use, if they are cleaned with recommended buffers that do not chemically degrade the media. In contrast, anion-exchange (AEX) columns that are not cleaned or are cleaned with buffers that chemically degrade the media lost viral clearance capacity after extended use. In these cases, other performance attributes that changed at the same time were increased band spreading, decreased DNA clearance and accumulating backpressure that prevented re-use past 80-120 cycles. Thus, our data suggests that flow through mode anion-exchange columns that are cleaned with recommended cleaning buffers, and periodically monitored for band spreading, DNA clearance and/or backpressure need not be re-evaluated for viral clearance at the end of the validated media lifetime. 相似文献
16.
The purpose of this study was to compare the intensity of the immunogold labeling of H(2)O(2)-treated and heated epoxy sections. Renal swine tissue with glomerular immune complex deposits with reactivity against IgG was embedded in epoxy resin. Immunogold labeling with anti-IgG was performed on sections from these blocks. Some of these sections were treated by H(2)O(2), others were heated in a citrate solution, while some were not treated at all. Some epoxy sections, which had been exposed to both H(2)O(2) and heat, were also exposed to the same immunolabeling. The heated epoxy sections obtained an yield of specific immunogold labeling, which was twice as large as the labeling of the H(2)O(2)-treated sections. The yield of immunolabeling of the sections that had been exposed to both H(2)O(2) and heat was not significantly different from the sections that were only exposed to heat. The non-treated sections were very weakly labeled with anti-IgG. We believe that both H(2)O(2) and heat have the ability to break some chemical bonds between the epoxy resin and the antigens, but heating in citrate buffer has a larger potential in this respect than H(2)O(2). We interpret the results from the combined treatment with H(2)O(2) and heat in the following way; the bonds that are broken by H(2)O(2) will also be broken by heating in citrate solution. The practical significance of these results is that heating in citrate buffer is a more convenient method for enhancing the immunolabeling of epoxy sections than treatment with H(2)O(2). 相似文献
17.
Robustness of virus removal by protein A chromatography is independent of media lifetime 总被引:1,自引:0,他引:1
Lute S Norling L Hanson M Emery R Stinson D Padua K Blank G Chen Q Brorson K 《Journal of chromatography. A》2008,1205(1-2):17-25
The robustness of virus clearance with respect to protein A media reuse was demonstrated using media with four matrix chemistries: Protein A immobilized ProSep A, Poros A50, Protein A ceramic Hyper DF and MabSelect SuRe, an alkali resistant protein A ligand. Endogenous retrovirus clearance, step yield, impurity clearance and other performance parameters were evaluated periodically in media cycled up to 300 times. Media lifetime was generally limited by either declining step yield or media fouling. However, clearance of endogenous retrovirus remained in an acceptable range, either increasing or remaining constant. Multiply cycled media were tested for clearance of three viruses (SV40, X-MuLV, and MMV); clearance was comparable to na?ve media. Overall, virus clearance by protein A chromatography appears to be extremely robust with respect to media age. 相似文献
18.
We report herein the synthesis of cytotoxic cyanobactin, Wewakazole B through an efficient solution-phase approach. The key steps of the synthesis are the macrocyclic lactamization of linear dodecapeptide and construction of two hexapeptides with three different substituted oxazole rings. 相似文献
19.
Jakobsen HJ Hove AR Bildsøe H Skibsted J Brorson M 《Journal of magnetic resonance (San Diego, Calif. : 1997)》2007,185(1):159-163
Experimental and simulated 14N MAS NMR spectra of the NH4+ ions in the two polymorphs, mS60 and mP60, of (NH4)2MoO4 are used to illustrate that a long-term stability of rotor-controlled MAS frequencies to 0.1 Hz can be achieved using commercial instrumentation (MAS speed controller and 7.5 mm MAS probe with a single marked rotor) attached to a highly pressure-stabilized air supply. A new modification of the STARS simulation software employs a Gaussian distribution for the experimental spinning frequency around the frequency set for the MAS speed controller. A simulated spectrum is then obtained by summation of several calculated spectra for evenly spaced spinning frequencies around the set frequency with relative weight factors corresponding to the Gaussian distribution. 相似文献