排序方式: 共有76条查询结果,搜索用时 15 毫秒
11.
L. Pienkowski A. Lleres H. Nifenecker J. Blachot J. Crancon A. Gizon M. Maurel C. Ristori 《Zeitschrift für Physik A Hadrons and Nuclei》1989,334(3):315-327
The angular and velocity distributions of incomplete fusion residues have been measured, around 30 AMeV projectile incident energy, for a number of systems with varying mass asymmetries, from the most asymmetric S+Cu, to the almost symmetric Ar+Ca. The main experimental finding is that the parallel width of the velocity distribution increases sharply for decreasing asymmetries, while the perpendicular width remains nearly constant. Using, as data, the widths and mean values of the velocity distributions, it was possible to derive the number of preequilibrium particles emitted by the projectile and by the target. It was found that target emission becomes noticeable only when the center of mass velocity of the target, at nuclear contact, exceeds approximately 2.5 cm/ns. This underlines the relevance of the center of mass velocities in the preequilibrium emission and incomplete fusion processes. 相似文献
12.
Using the approach of Rulla (1996 SIAM J. Numer. Anal. 33, 68-87)for analysing the time discretization error and assuming moreregularity on the initial data, we improve on the error boundderived by Barrett and Blowey (1996 IMA J. Numer. Anal. 16,257-287) for a fully practical piecewise linear finite elementapproximation with a backward Euler time discretization of amodel for phase separation of a multi-component alloy. 相似文献
13.
Bulten HJ Anthony PL Arnold RG Arrington J Beise EJ Belz E van Bibber K Bosted PE van den Brand JF Chapman MS Coulter KP Dietrich FS Ent R Epstein M Filippone BW Gao H Gearhart RA Geesaman DF Hansen J Holt RJ Jackson HE Jones CE Keppel CE Kinney E Kuhn SE Lee K Lorenzon W Lung A Makins NC Margaziotis DJ McKeown RD Milner RG Mueller B Napolitano J Nelson J O'Neill TG Papavassiliou V Petratos GG Potterveld DH Rock SE Spengos M Szalata ZM Tao LH White JL Zeidman B 《Physical review letters》1995,74(24):4775-4778
14.
15.
16.
17.
18.
19.
H. A. Selič G. Sadler T. A. Khan W. -D. Lauppe H. Lawin K. Sistemich E. Monnand J. Blachot J. P. Bocquet F. Schussler 《Zeitschrift für Physik A Hadrons and Nuclei》1979,289(2):197-210
Theβ-decays of99Y and99Zr have been investigated with the two recoil fission product separators JOSEF and LOHENGRIN. Half-lives of 1.51±0.08s and 2.1±0.1s respectively, have been determined. Aβ-decaying isomeric state has been observed in99Y. The level schemes of 40 99 Zr59 and 41 99 Nb58 have been established fromγ-ray spectroscopy. Absoluteγ-intensities have been obtained by means of two independent techniques. Halflives of 293±10 ns for the 251.9 keV state and 10.2±1.5 ns for the 614.0 or 667.2 keV level in99Zr have been measured through delayedβ,γ- andγ,γ-coincidence experiments. Values for the spins and parities of the low lying levels in99Zr are proposed in accordance with the systematics of lighter odd Zr isotopes. Spins and partities are assigned to some levels in99Nb fromγ,γ-angular correlation measurements. In this nucleus there is evidence for three-particle configurations of some excited states, where the odd proton is coupled to two neutrons which are in different orbits. 相似文献
20.
KM Clauwaert Van Bocxlaer JF HJ Major JA Claereboudt WE Lambert Van den Eeckhout EM Van Peteghem CH De Leenheer AP 《Rapid communications in mass spectrometry : RCM》1999,13(14):1540-1545
This paper describes the investigation of the potential of a quadrupole orthogonal acceleration time-of-flight mass spectrometer (Q-TOF) equipped with an atmospheric pressure ionisation interface for quantitative measurements of small molecules separated by reversed phase liquid chromatography. To this end, the detection limits and linear dynamic range in particular were studied in an LC/MS/MS experiment using 3,4-methylenedioxymethamphetamine standards and 3,4-methylenedioxyethylamphetamine for internal standardisation. In a second phase, the experiment was repeated with real biological extracts (whole blood, serum, and vitreous humour). A calibration for 3,4-methylenedioxymethamphetamine and its metabolite 3,4-methylenedioxyamphetamine was prepared in each of these matrices again using 3,4-methylenedioxyethylamphetamine as internal standard. The resulting quantitative data were compared with those obtained by liquid chromatography with fluorescence detection for the same extracts. The Q-TOF results revealed excellent sensitivity and a linear dynamic range of nearly four decades (2-10 000 pg on-column, r(2) = 0.9998, 1/x weighting). Furthermore, all the calibration curves prepared in biological material were superimposable, LC/MS/MS and LC-fluorescence, and the quantitative results for actual samples compared very favourably. It was concluded that the Q-TOF achieves a linear dynamic range for quantitative LC/MS/MS work exceeding that of fluorescence detection and at much better absolute sensitivity. Copyright 1999 John Wiley & Sons, Ltd. 相似文献