全文获取类型
收费全文 | 58篇 |
免费 | 0篇 |
专业分类
化学 | 31篇 |
力学 | 1篇 |
数学 | 19篇 |
物理学 | 7篇 |
出版年
2023年 | 1篇 |
2022年 | 3篇 |
2021年 | 2篇 |
2020年 | 1篇 |
2019年 | 2篇 |
2017年 | 2篇 |
2016年 | 3篇 |
2015年 | 2篇 |
2014年 | 1篇 |
2013年 | 5篇 |
2012年 | 4篇 |
2011年 | 3篇 |
2010年 | 2篇 |
2008年 | 4篇 |
2007年 | 2篇 |
2006年 | 1篇 |
2005年 | 1篇 |
2002年 | 3篇 |
2000年 | 2篇 |
1999年 | 1篇 |
1997年 | 1篇 |
1996年 | 1篇 |
1995年 | 2篇 |
1994年 | 1篇 |
1993年 | 1篇 |
1992年 | 3篇 |
1990年 | 1篇 |
1988年 | 1篇 |
1985年 | 1篇 |
1984年 | 1篇 |
排序方式: 共有58条查询结果,搜索用时 15 毫秒
1.
Boscaro F Pieraccini G la Marca G Bartolucci G Luceri C Luceri F Moneti G 《Rapid communications in mass spectrometry : RCM》2002,16(16):1507-1514
A method for measuring globotriaosylceramide (Gb3, or GL3) levels in plasma and urine of humans affected by Anderson-Fabry disease has been developed. The analyses are performed using flow injection analysis-electrospray ionization-tandem mass spectrometry (FIA-ESI-MS/MS). The method is rapid, sensitive and hence suitable for high-throughput analyses, requiring only a simple 50-fold dilution for the preparation of plasma and urine samples. The detection of the analytes of interest was achieved using a triple quadrupole instrument operating in the multiple reaction monitoring mode. The linearity of the calibration standard responses, the intra- and inter-assay precision, the accuracy and the detection limit of the method were evaluated. The proposed method allows a rapid and accurate assessment of globotriaosylceramide in biological samples. Data obtained from healthy volunteers and Anderson-Fabry affected subjects suggest a potential role for this technique in monitoring the effectiveness of Anderson-Fabry disease therapy. The results obtained in two actual cases treated with enzyme replacement therapy are reported and discussed. 相似文献
2.
A method for the determination of phenoxyalkanoic acids and other polar compounds in environmental water samples without pH adjustment before extraction has been developed. Recoveries were calculated from 500 ml of milliQ water spiked at the level of 0.5 ng/ml using solid-phase extraction (SPE) and HPLC-DAD. Different SPE materials (RP-C18, ENV+, ENV+-C8, SAX and Oasis HLB) were tested. After method optimization, 15 of the 16 compounds studied could be extracted with recoveries better than 70% on the most suitable copolymeric poly(divinylbenzene-co-N-vinylpyrrolidone) material (Oasis HLB cartridges). 相似文献
3.
Chiara Lavarello Sebastiano Barco Martina Bartolucci Isabella Panfoli Emanuele Magi Gino Tripodi Andrea Petretto Giuliana Cangemi 《Molecules (Basel, Switzerland)》2021,26(14)
Liquid-chromatography coupled to high resolution mass spectrometry (LC-HRMS) is currently the method of choice for untargeted metabolomic analysis. The availability of established protocols to achieve a high confidence identification of metabolites is crucial. The aim of this work is to describe the workflow that we have applied to build an Accurate Mass Retention Time (AMRT) database using a commercial metabolite library of standards. LC-HRMS analysis was carried out using a Vanquish Horizon UHPLC system coupled to a Q-Exactive Plus Hybrid Quadrupole-Orbitrap Mass Spectrometer (Thermo Fisher Scientific, Milan, Italy). The fragmentation spectra, obtained with 12 collision energies, were acquired for each metabolite, in both polarities, through flow injection analysis. Several chromatographic conditions were tested to obtain a protocol that yielded stable retention times. The adopted chromatographic protocol included a gradient separation using a reversed phase (Waters Acquity BEH C18) and a HILIC (Waters Acquity BEH Amide) column. An AMRT database of 518 compounds was obtained and tested on real plasma and urine samples analyzed in data-dependent acquisition mode. Our AMRT library allowed a level 1 identification, according to the Metabolomics Standards Initiative, of 132 and 124 metabolites in human pediatric plasma and urine samples, respectively. This library represents a starting point for future metabolomic studies in pediatric settings. 相似文献
4.
Francesco Bartolucci Francesca Chiaromonte Prabhani Kuruppumullage Don Bruce G. Lindsay 《Journal of computational and graphical statistics》2017,26(2):388-402
We consider a discrete latent variable model for two-way data arrays, which allows one to simultaneously produce clusters along one of the data dimensions (e.g., exchangeable observational units or features) and contiguous groups, or segments, along the other (e.g., consecutively ordered times or locations). The model relies on a hidden Markov structure but, given its complexity, cannot be estimated by full maximum likelihood. Therefore, we introduce a composite likelihood methodology based on considering different subsets of the data. The proposed approach is illustrated by simulation, and with an application to genomic data. 相似文献
5.
Motivated by the study of gauge field vortices, we consider a mean field equation on the standard sphere 𝕊2 involving a Dirac distribution supported at a point P ∈ 𝕊2. Consistently with the physical applications, we show that solutions “concentrate” precisely around the point P for some limiting value of a given parameter. We use this fact to obtain symmetry (about the axis ) and uniqueness property for the solution. The presence of the Dirac measure makes such a task particularly delicate to handle from the analytical point of view. In fact, the bubbling phenomenon about the singularity allows the existence of solution sequences with a double‐peak profile near P. The new and more delicate part of this paper is to exclude this possibility by using the method of moving planes together with the Alexandrov‐Bol inequality. © 2011 Wiley Periodicals, Inc. 相似文献
6.
Lucarini S Bartolucci S Bedini A Gatti G Orlando P Piersanti G Spadoni G 《Organic & biomolecular chemistry》2012,10(2):305-313
An efficient and practical approach for the synthesis of all four stereoisomers of the MT(2) melatonin receptor ligand 4-phenyl-2-propionamidotetralin (4-P-PDOT), each in enantiomerically pure form (ee > 99.9%), was developed. The strategy involved an optical resolution procedure of the key precursor (±)-4-phenyl-2-tetralone with the unusual resolving agent (S)-mandelamide, through the formation of four dihydronaphtalene-spiro-oxazolidin-4-one diastereomers. Interestingly, NMR experimental observations in combination with geometric calculations, provided unambiguous configuration assignments of all stereocenters of the key spiro stereoisomers. Cleavage of each single spiro diastereomer under acidic conditions gave enantiopure (R)- or (S)-4-phenyl-2-tetralone, which were then converted to each 4-P-PDOT single enantiomer by using stereoselective reactions. 相似文献
7.
Cecilia Bartolucci Luciano Cellai Concetta Martuccio Andrea Rossi Anna Laura Segre Simona Rizea Savu Luigi Silvestro 《Helvetica chimica acta》1996,79(6):1611-1619
Glycosylrifamycins, a new type of semisynthetic rifamycin derivatives, can be easily obtained by reaction of 3-(2-aminoethylthio)rifamycin SV ( 2 ) with a glycosyl compound carrying a coupling group, such as isothicyanate or carboxy. We prepared O-acetylated and free glucopyranosyl and arabinopyranosyl derivatives of rifamycin S and SV (see 3–10 ). Additionally, derivatives with D -saccharo-1,4-lactone and with shikimic acid were obtained (see 11–15 ). Glycosylrifamycins show an interesting inhibitory power on Gram-positive bacteria (Table). 相似文献
8.
9.
The validation of a HPTLC-densitometric method for the determination of secoisolariciresinol diglucoside (SDG) in flaxseed was performed improving the reproducibility of a previously reported HPTLC densitometric procedure by the use of fully wettable reversed phase plates (silica gel 60 RP18W F(254S), 10cmx10cm) with MeOH:HCOOH 0.1% (40:60, v/v) mobile phase. The analysis required only the alkaline hydrolysis in aqueous medium of undefatted samples and densitometry at 282nm of HPTLC runs. The method was validated following the protocol proposed by the Société Francaise des Sciences et Techniques Pharmaceutiques (SFSTP) giving rise to a dependable and high throughput procedure well suited to routine application. SDG was quantified in the range of 321-1071ng with RSD of repeatability and intermediate precision not exceeding 3.61% and accuracy inside the acceptance limits. Flaxseed of five cultivars of different origin was elected as test-bed. 相似文献
10.