全文获取类型
收费全文 | 55篇 |
免费 | 0篇 |
国内免费 | 1篇 |
专业分类
化学 | 21篇 |
数学 | 5篇 |
物理学 | 30篇 |
出版年
2020年 | 2篇 |
2015年 | 1篇 |
2013年 | 2篇 |
2012年 | 2篇 |
2011年 | 1篇 |
2010年 | 1篇 |
2008年 | 1篇 |
2007年 | 3篇 |
2006年 | 1篇 |
2005年 | 2篇 |
2004年 | 2篇 |
2003年 | 3篇 |
2002年 | 4篇 |
2001年 | 2篇 |
2000年 | 1篇 |
1999年 | 1篇 |
1998年 | 1篇 |
1996年 | 1篇 |
1995年 | 2篇 |
1991年 | 1篇 |
1990年 | 2篇 |
1989年 | 1篇 |
1988年 | 1篇 |
1987年 | 2篇 |
1985年 | 2篇 |
1984年 | 4篇 |
1983年 | 2篇 |
1980年 | 2篇 |
1977年 | 2篇 |
1976年 | 2篇 |
1975年 | 1篇 |
1974年 | 1篇 |
排序方式: 共有56条查询结果,搜索用时 31 毫秒
21.
Analytical capillary isotachophoresis: a routine technique for the analysis of lipoproteins and lipoprotein subfractions in whole serum 总被引:2,自引:0,他引:2
A capillary isotachophoretic separation technique was developed for lipoproteins in native serum which, compared with previous electrophoretic techniques, has negligible molecular sieve effects, does not need gel casting, is suitable for whole serum and has a high discriminative power for lipoprotein subfractions. The technique is based on pre-staining whole serum lipoproteins for 30 min at 4 degrees C before separation of 0.5 microliter of the sample in a free-flow capillary system (0.5 mm I.D.) with discontinuous buffer system. In normolipidaemic sera, high-density (HDL) and low-density lipoproteins (VLDL) are separated into two major subpopulations according to their net electric mobility. The identification of these fractions was confirmed by substitution with ultracentrifugally isolated lipoproteins and by their complete absence from Tangier and abetalipoproteinaemic serum. Triglyceride-rich very low-density lipoproteins (VLDL) revealed a defined zone between the HDL and LDL subpopulations. Our preliminary results indicate that the separation of human whole serum lipoproteins by capillary isotachophoresis is a promising method for the determination of lipoprotein subfractions. 相似文献
22.
The determination of the centre-of-mass energies from the LEP1 data for 1993, 1994 and 1995 is presented. Accurate knowledge
of these energies is crucial in the measurement of the Z resonance parameters. The improved understanding of the LEP energy
behaviour accumulated during the 1995 energy scan is detailed, while the 1993 and 1994 measurements are revised. For 1993
these supersede the previously published values. Additional instrumentation has allowed the detection of an unexpectedly large
energy rise during physics fills. This new effect is accommodated in the modelling of the beam-energy in 1995 and propagated
to the 1993 and 1994 energies. New results are reported on the magnet temperature behaviour which constitutes one of the major
corrections to the average LEP energy. The 1995 energy scan took place in conditions very different from the previous years.
In particular the interaction-point specific corrections to the centre-of-mass energy in 1995 are more complicated than previously:
these arise from the modified radiofrequency-system configuration and from opposite-sign vertical dispersion induced by the
bunch-train mode of LEP operation. Finally an improved evaluation of the LEP centre-of-mass energy spread is presented. This
significantly improves the precision on the Z width.
Received: 25 March 1998 / Revised version: 3 August 1998 / Published online: 29 October 1998 相似文献
23.
Bharadwaj SV Tobey EA Assmann PF Katz WF 《The Journal of the Acoustical Society of America》2006,119(3):1626-1635
Acoustic analyses and perception experiments were conducted to determine the effects of brief deprivation of auditory feedback on fricatives produced by cochlear implant users. The words /si/ and /Si/ were recorded by four children and four adults with their cochlear implant speech processor turned on or off. In the processor-off condition, word durations increased significantly for a majority of talkers. These increases were greater for children compared to adults, suggesting that children may rely on auditory feedback to a greater extent than adults. Significant differences in spectral measures of /S/ were found between processor-on and processor-off conditions for two of the four children and for one of the four adults. These talkers also demonstrated a larger /s/-/S/ contrast in centroid values compared to the other talkers within their respective groups. This finding may indicate that talkers who produce fine spectral distinctions are able to perceive these distinctions through their implants and to use this feedback to fine tune their speech. Two listening experiments provided evidence that some of the acoustic changes were perceptible to normal-hearing listeners. Taken together, these experiments indicate that for certain cochlear-implant users the brief absence of auditory feedback may lead to perceptible modifications in fricative consonants. 相似文献
24.
Characterization of an apolipoprotein C-III mutant by high-performance liquid chromatography and time-of-flight secondary ion mass spectrometry 总被引:1,自引:0,他引:1
Apolipoprotein (apo) C-III isoforms from a patient with a mutant apo C-III and from controls were isolated to homogeneity by isoelectric focusing and subjected to proteolytic digestion. The peptides obtained were separated by reversed-phase high-performance liquid chromatography, and their molecular masses were determined by time-of-flight secondary ion mass spectrometry. Molecular masses of peptides derived from apo C-III0, C-III1 and C-III2 were indistinguishable from control preparations, whereas the mutant apo C-III contained a COOH-terminal, carbohydrate-containing peptide with an abnormal retention time in high-performance liquid chromatography and a molecular mass higher by 291 daltons owing to oversialation at position 74 of the amino acid sequence (apo C-III3). 相似文献
25.
A BASIC program is described for acquisition of data and data reduction for an automated densitometric system for quantitation of lipids separated by high-performance thin-layer chromatography. The program allows calculation of mass of samples from log/log calibration curves computed from standards. The calculated masses are reported as nmol/volume or nmol/mg protein. The program contains a flexible dialog system which permits its use for a variety of applications in addition to the system described for quantitation of lipids. 相似文献
26.
27.
Covariation in the size of laryngeal and vocal tract structures leads to a moderate correlation between fundamental frequency (F0) and formant frequencies (FFs) in natural speech. A method of adjustment procedure was used to test whether listeners prefer combinations of F0 and FFs that reflect this covariation. Vowel sequences spoken by two men and two women were processed by the STRAIGHT vocoder to construct three sets of frequency-shifted continua. The distributions of "best choice" responses in all three experiments confirm that listeners prefer coordinated patterns of F0 and FF similar to those of natural speech. 相似文献
28.
Abstract By means of magnetic circular dichroism of the optical absorption and photostimulated luminescence (PSL) the X-ray induced formation of FA and F centres in RbBr:(Ga+, Li+) was investigated. It turnes out that RbBr:Ga+ co-doped with 1% Li+ in the melt reveals the largest red-shift of the PSL excitation bands to 790 nm, whereby the FA to F ratio increases up to about 10% with decreasing X-ray dose. This is more than statistically expected (6%). High X-ray doses destroy FA centres. However, up to 15% of the simultaneously generated F centres could be converted into the FA species by appropriate bleaching with 633 nm light into the F centre absorption band. 相似文献
29.